summaryrefslogtreecommitdiff
path: root/57335-0.txt
blob: 21d9627796b2d0a99a235252e2db4f3ed2f3b9bf (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
*** START OF THE PROJECT GUTENBERG EBOOK 57335 ***












                       LIGHT AND COLOUR THEORIES

[Illustration: TINTOMETER. Form of Instrument for Opaque Observation.]




[Illustration: Reproductions of some Medals awarded to JOSEPH W. LOVIBOND’S
Method of Colour Analysis FOR Scientific and Commercial Purposes.]




                               LIGHT AND
                            COLOUR THEORIES

                    and their Relation to Light and
                        Colour Standardization

                                  By

                          JOSEPH W. LOVIBOND

               ILLUSTRATED BY 11 PLATES COLOURED BY HAND

[Illustration: Logo]

                                London

            E. & F. N. SPON, Limited, 57 HAYMARKET

                               New York

                SPON & CHAMBERLAIN, 123 LIBERTY STREET

                                 1915




CONTENTS


                                                             PAGE

  List of Plates                                              vii

  Purpose                                                      ix


                          CHAPTER I.
  Introduction                                                  1


                          CHAPTER II.
  Evolution of the Method                                       5


                          CHAPTER III.
  Evolution of the Unit                                         9


                          CHAPTER IV.
  Derivation of Colour from White Light                        11


                          CHAPTER V.
  Standard White Light                                         14


                          CHAPTER VI.
  Qualitative Colour Nomenclature                              17


                          CHAPTER VII.
  Quantitative Colour Nomenclature

                          CHAPTER VIII.
  The Colour Scales                                            28


                          CHAPTER IX.
  Colour Charts                                                31


                          CHAPTER X.
  Representations of Colour in Space of Three Dimensions       34


                          CHAPTER XI.
  The Spectrum in relation to Colour Standardization           36


                          CHAPTER XII.
  The Physiological Light Unit                                 45


                          APPENDIX I.
  Colour Education                                             59


                          APPENDIX II.
  The Possibilities of a Standard Light and Colour Unit        69

                          APPENDIX III.
  Dr. Dudley Corbett’s Radiometer                              83


  Index                                                        89




ERRATA.


    Plate I. Newton’s Theory. The Indigo line is erroneously placed
    between the Violet and the Red; it should be between the Blue
    and the Violet.

    Page 40.--_Fifth line from the bottom, for_ Fraunhoper _read_
    Fraunhofer.


_To face p. vi., Lovibond, Light and Colour Theories._] [P.R. 1317




LIST OF PLATES


                                                           TO FACE
                                                             PAGE

  Plate  I. Six Colour Theories                                 4

    "   II. Circles Illustrating Absorption of White Light     11

    "  III. Diagram Illustrating Analysis of White Light       13

    "   IV. First System of Charting Colour                    31

    "    V. Second System of Charting Colour                   33

    "   VI. Six Tintometrical Colour Charts                    39

    "  VII. Two Circles                                        40

    " VIII. Absorption Curves of Dyes                          76

    "   IX. Fading Curves of Dyes                              78

    "    X. Comparison Curves of Healthy and Diseased Blood    80

    "   XI. Specific Colour Curves of Healthy and Diseased
            Human Blood                                        82




PURPOSE


The purpose of this work is to demonstrate that colour is a
determinable property of matter, and to make generally known methods
of colour analysis and synthesis which have proved of great practical
value in establishing standards of purity in some industries.

The purpose is also to show that the methods are thoroughly scientific
in theory and practice, and that the results are not likely to be
changed by further discoveries. Also that out of the work done a new
law has been developed, which the writer calls the Law of Specific
Colour Development, meaning that every substance has its own rate of
colour development for regularly increasing thicknesses.


THE THEORY.

Of the six colours in white light--red, orange, yellow, green, blue
and violet; Red, Yellow and Blue are regarded as dominants, because
they visually hold the associated colours orange, green and violet in
subjection.

An equivalent unit of pure red, pure yellow and pure blue is adopted,
and incorporated into glass. The unit is multiplied to obtain greater
intensities, and divided to obtain lesser intensities.

The coloured glasses are called absorbents. The red absorbent transmits
violet, red and orange, but the red ray alone is visible as colour,
until the other absorbents are superimposed, and the character of the
group of rays changed. In the same way yellow transmits orange and
green, and blue transmits green and violet, whilst the yellow and blue
alone are visible as colour. Orange, green and violet are here called
subordinates, which may be developed as follows:--

    Or. = R. + Y.   Gr. = Y. + B.   Vi. = B. + R.

Twenty-five years’ experience in the application of the theory and the
method to the requirements of practical work, have given no reason for
change. Following will be found a list of awards from International
Juries and Scientific Societies, also a list of industries in which the
writer’s method is giving entire satisfaction.


Awards by International Juries.

  St. Louis                1 Silver Medal.
                           2 Bronze Medals.

  Brussels                 1 Gold Medal.
                           3 Silver Medals.

  Turin                    Diploma of Honour.
                           1 Gold Medal.
                           1 Silver Medal.


Awards by Scientific Societies.

  Sanitary Institute of Great Britain--
      _Bronze_ Medal for Colourometrical Water Analysis.

  Royal Sanitary Institute--
      _Bronze_ Medal for Measuring Smoke Densities.

  International Congress on School Hygiene--
      _Bronze_ Medal for Colour Educator.

  Royal Sanitary Institute--
      _Silver_ Medal for Colour Educator.

  Smoke Abatement Society, Sheffield--
      _Diploma_ for System of Colour Measurement.

  Royal Sanitary Institute--
      _Bronze_ Medal for Quantitative Estimation of Colour Blindness.

  Franco-British Exhibition--
      _Gold_ Medal for Colour Educator.

  International Medical Congress--
      _Bronze_ Medal for Tintometer as Medical requisite.

  Royal Sanitary Institute--
      _Silver_ Medal for recent developments.

  Royal Sanitary Institute--
      _Silver_ Medal Corbett’s Radiometer.

Formal Adoption of Tintometer Standards by--

  The Petroleum Industry.
  The Massachusetts Board of Health.
  The International Association of Leather Trades Chemists.
  The Inter-states Cotton Seed Oil Association.
  The Bureau of Engraving and Printing, China.

In general use by the following Industries--

  Brewing and Malting.
  Tanning.
  Wine and Spirit Merchants.
  Dyeing and Printing.
  Paint, Oil and Varnish Merchants.
  Millers.
  Water Works Chemists.
  Ceramic Works.
  For estimating per cent. of Carbon in Steel.
  For estimating per cent. of Ammonia.
  For estimating Colours for Anthropological Classifications.
  For estimating Smoke Densities.
  For estimating Haemoglobin in the Blood.
  For estimating Colour of Whale Oil, etc., etc.


THE METHOD.

The colour composition of any object may be measured by superimposing
units of different colours until the colour of the object is matched. A
convenient apparatus is furnished for this purpose. The composition of
the colour is learned by merely reading the markings on the glasses.

It is of course necessary that in the isolation of colour rays,
some unit for measuring the intensity of both light and colour be
established. As will be explained later, all such units are necessarily
arbitrary. In this method the unit has been established by taking the
smallest amount of colour easily perceptible to the ordinary vision.
This unit or “one” is divided into tenths in the darker shades, and
hundredths in the lighter scale. One one-hundredth is the smallest
amount of colour measurable by a normal trained vision.

When equivalent units in the three colours are superimposed, their
equivalent value (not their aggregate value) represents so much white
light absorbed. For instance, 2 R. + 2 Y. + 2 B. absorbs two units of
white light.

When the absorptive power of the colour standards is less than the
intensity of the light, associated white light remains.

  JOSEPH W. LOVIBOND.

  The Colour Laboratories,
  Salisbury.

  _December, 1914._




Light and Colour Theories




CHAPTER I.

Introduction.


It may at first appear strange that colour, one of the most important
indices of value in the Arts, Manufactures, and Natural Products,
should have no common nomenclature or reliable standard for reference,
the reproduction of a given colour depending for exactitude on the
memory of a sensation; whereas this branch of science requires a
physical means of recording a colour, with a power of recovery. It
remains to be shown that this power of record and recovery is possible,
and depends only on the observance of a few simple natural laws easy of
application.

The study of colour is carried on by two principal methods: the
spectroscopic, where the colours are partially separated as a
continuous band by a regular variation in their indices of refraction,
the colours gradually merging into each other by overlapping in
opposite directions; or by absorption, where a colour is developed by
absorbing its complementary, and is isolated as a single or complex
colour. This latter is nature’s own method.

It is necessary to touch on some theoretical differences which exist
between Scientists and Artists, as to which are Primary colours, as
confusion of this character retards investigation. Scientists adopt
Red, Green, and Violet as Primaries, regarding all other colours as
mixtures of these; whilst Artists and Colourists adopt Red, Yellow and
Blue as the Primaries, and all other colours as made from them.

The theory of the Scientists is based on the phenomena developed by
mixing coloured lights taken from different parts of the spectrum.
This is a method of synthesis, each added colour being a progressive
stage towards the complexity of white light. In this case the colour
developed is that of the preponderating ray of a complex beam. The
theory of the Artists is based on the phenomena developed by mixed
pigments. This is a method of analysis, tending towards ray simplicity,
each added pigment reducing the complexity of the colour developed by
its power of selective absorption.

The theoretical differences between the two schools appear to have
arisen from supposing that a given colour developed by the two
methods should correspond; but considering the differences in their
ray composition, this would be impossible, for although both may be
describable by one general colour term, as for instance a Red, they
would be of two varieties. It remains to be shown that one theory may
cover both sets of phenomena.

The Red, Green, and Violet theory appears to be based on two principal
assumptions: first that there are only three fundamental colours;
and second that the rays taken from different colour areas are pure
colours. Both assumptions are open to question. In regard to the first,
there is no difficulty in isolating six colours; and as to the second,
it can be demonstrated that the colours do overlap in every part, with
a double overlapping in the middle colours, and are therefore not
simple but complex.


PAST THEORIES.

In a work of this nature it is unnecessary to deal minutely with the
theories which have been adopted from time to time since Newton’s
discovery of the continuous spectrum. It will, however, be useful to
touch on the principal points where theorists are agreed, and also on
some of their points of difference, the latter in order to find, if
possible, the causes of their difference.


TABLE I.

  ----------------+-----+-------------------------------------------------
                  | No. |
                  | of  |               Primary Colours.
                  |Rays.|
  ----------------+-----+-------------------------------------------------
  Newton (later)  |  7  | Red, Orange, Yellow, Green, Blue, Indigo, Violet
                  |     |
  Werner          |  6  | Red, Orange, Yellow, Green, Blue,         Violet
                  |     |
  Newton and      |     |
  Helmholtz       |  5  | Red,         Yellow, Green, Blue,         Violet
   (early)        |     |
                  |     |
  Hering          |  4  | Red,         Yellow, Green, Blue
                  |     |
  Chevieul,       |     |
  Brewster, Hay,  |     |
  Redgrave, Field |  3  | Red,         Yellow,        Blue
                  |     |
  Young, Helmholtz|     |
    (later)       |  3  | Red,                 Green,               Violet
  ----------------+-----+-------------------------------------------------

                       Note to Plate I.

    The respective positions of the primaries of each theory in
    regard to the whole cycle of distinguishable colours are
    illustrated above, and the primaries of each theory are shown
    in their several spectrum positions, the spectrum being shown
    as bent in circular form.

The six principal theories of primary colours are given in Table I,
and illustrated on Plate I, with the names of the primaries of each
theory opposite the names of some of their principal advocates. It
should not be forgotten when comparing these wide divergences, that
each theory has been the result of experimental evidence, in what was,
at the time, and remains up to the present, a new and progressive
branch of science.

They agree that the spectrum colours are purer than the pigmentary
colours, and that by reason of their being referable to wave length
positions, they are most adaptable as standards of colour. There has
also been common agreement that certain colours are primaries, and
that all other colours are mixtures of these, but there has been wide
divergence as to their number and even the colours themselves.

[Illustration: PLATE I ILLUSTRATING THE POSITION OF THE PRIMARIES IN
RELATION TO THE COLOURS REQUIRED TO BE PRODUCED BY THE THEORETICAL
MIXTURES AND ALSO IN RELATION TO THE CHROMATIC CIRCLE.

  A SEVEN RAY THEORY. NEWTON.

  A SIX RAY THEORY. WERNER.

  A FIVE RAY THEORY. NEWTON (_Early_). HELMHOLTZ (_Early_).

  A FOUR RAY THEORY. HERING.

  A THREE RAY THEORY. CHEVREUL. BREWSTER. HAY. REDGRAVE. FIELD.

  A THREE RAY THEORY. YOUNG-HELMHOLTZ.

  _To face page 4._]      [_Lovibond, Colour Theories._
]




CHAPTER II.

Evolution of the Method.


The writer was formerly a brewer, and this work had its origin in an
observation that the finest flavour in beer was always associated
with a colour technically called “golden amber,” and that, as the
flavour deteriorated, so the colour assumed a reddish hue. It was these
variations in tint that suggested the idea of colour standards as a
reliable means of reference.

The first experiments were made with coloured liquids in test tubes
of equal diameter, and by these means some useful information was
obtained; but as the liquids soon changed colour, frequent renewals
were necessary, and there was always a difficulty and uncertainty in
their exact reproduction.

To obviate this, glass in different colours was tried, and long
rectangular wedges with regularly graded tapers were ground and
polished for standards, whilst correspondingly tapered glass vessels
were made for the beers. These were arranged to work side by side,
and perpendicularly, before two apertures of an optical instrument,
which gave a simultaneous view of both. The apertures were provided
with a fixed centre line, to facilitate the reading off of comparisons
of thickness. There was no difficulty in obtaining glass which
approximated to the required colour when used in one thickness only.
But as thickness varied, the test no longer held good for both
standards, their rates of colour change being different, making the
method unreliable.[1]

[1] It was afterwards found that these colour changes through
variations of intensities were due to a natural law to be described
under the heading of “Specific colour.” (_See_ page 32.)

The system about to be described is one of analytical absorption, and
has been published from time to time in the form of papers, read before
Societies interested in the question of colour standardization; as also
in two descriptive works by the present writer. The earlier works were
necessarily fragmentary, but gathered system as the subject progressed.

At an early stage in the investigations it was realized that the
handbooks of the period dealt largely with theoretical differences
which were of little service to the technical worker. Under these
circumstances the writer applied for advice to the late Mr. Browning
of the Strand, who gave it as his opinion that no work existed which
could be of service to the writer. All that could be done was to go on
until something should be arrived at. On this, all theoretical reading
was put aside, and the work proceeded on the simple lines of observing,
recording, and classifying experimental facts.

In working with glass of different colours it was found that some
combinations developed colour, whilst other combinations destroyed
it. This suggested the probability of a governing natural law; and
experimental work was undertaken in the hope of discovering it. The
result was the construction of a mechanical scale of colour standards,
which are now in use in over one thousand laboratories, and no
question of their practical accuracy arises. The principal conditions
for ensuring accuracy and constancy of results are embodied in the
following code of nine precautions, which have been published for
nearly twenty years without being disputed. They may therefore be
considered as governing laws, at least for the present. The colour
theory adopted for these Governing Laws has grown out of a series of
experimental facts capable of demonstration, and is summed up in the
following code of nine Laws.

Laws 1, 2, and 3 relate to White and Coloured Light, and are as
follows:--

1. Normal white light is made up of the six colour rays, Red, Orange,
Yellow, Green, Blue and Violet in equal proportions. When these rays
are in unequal proportions the light is abnormal and coloured.

2. The particular colour of an abnormal beam is that of the
one preponderating ray, if the colour be simple, or of the two
preponderating rays if the colour be complex. The depth of colour is in
proportion to the preponderance.

3. The rays of a direct light are in a different condition to the
same rays after diffusion, and give rise to a different set of colour
phenomena.

Laws 4, 5, 6, and 7 deal with The Limitations of the Vision to
appreciate Colour.

4. The vision is not simultaneously sensitive to more than two colours
in the same beam of light. The colour of any other abnormal ray is
merged in the luminosity of the beam.

5. The two colours to which the vision is simultaneously sensitive
are always adjacent in their spectrum order, Red and Violet being
considered adjacent for this purpose.

6. The vision is unable to appreciate colour in an abnormal beam
outside certain limits, from two causes:

(_a_) The colour of an abnormal beam may be masked to the vision from
excess of luminosity.

(_b_) The luminous intensity of the abnormal beam may be too low to
excite definite colour sensations.

7. The vision has a varying rate of appreciation for different colours
by time, the lowest being for red. The rate increases in rapidity
through the spectrum, until the maximum rate is reached with violet.
And since this varying rate necessitates a time limit for critical
observations, five seconds has been adopted as the limit, no variations
being perceptible in that time.

Laws 8 and 9 relate to Colour Constants.

8. The colour of a given substance of a given thickness is constant so
long as the substance itself, and the conditions of observation, remain
unaltered.

9. Every definite substance has its own specific rate of colour
development for regularly increasing thicknesses.




CHAPTER III.

Evolution of the Unit.


The dimensions of the light and colour unit here adopted, together
with the scales of division, were in the first instance physiological,
depending entirely on the skill of normal visions for exactitude. The
co-relation of equal values in the different colour scales, was secured
by an elaborate system of cross-checking, rendered necessary because
the establishment of a perfectly colourless neutral tint unit, demanded
an exact balance in values of the different colour scales. These scales
have stood the test of many years’ work by many observers, and in no
case has any alteration been required. The original set is still in use.

The first point which required consideration after the want of standard
colour scales was realized, was the basis and dimensions of the unit.
So far as the writer knew there was no published information bearing on
this which could be used as a guide.

Several arbitrary scales for specific purposes had already been
constructed by selecting a colour depth which could easily be
distinguished, calling it a unit, and scaling it by duplicating and
subdividing. This course was adopted with a coloured glass which
approximately matched Ales and Malt solutions, and another which
matched Nesslerized Ammonia solutions. No insuperable difficulty
occurred in constructing scales available for quantitative work in
these two instances.

The intensity of the colour unit for these arbitrary scales, was that
which appeared to be most convenient for the purpose required, but the
several scales had no common basis. The unit was physiological, and the
exactitude of the scales depended entirely on the skill of the vision
for discriminating small differences.

As the writer’s experimental work progressed, it became evident that
red, yellow, and blue were the only colours suitable for systematic
work. The superimposition of any two, developed a third colour which
apparently had no relation to either. The superimposition of the third
glass modified or destroyed all colour and reduced the amount of light.
This suggested the idea that if the three colours could be so balanced
that the light transmitted was colourless, it would be evidence of
equivalence of intensity in the individual colours.

The real difficulty was in obtaining this equivalence, because a
balance which transmitted a neutral tint by one light developed colour
by another. This necessitated the selection of a standard light. The
light finally selected was that of a so-called sea fog, away from the
contaminating influence of towns. The white fog of Salisbury Plain was
used as being most available. It required two years’ work to establish
equivalence in the unit.

[Illustration: PLATE II NINE CIRCLES ILLUSTRATING THE ANALYSIS OF A BEAM
OF WHITE LIGHT INTO THE SIX COMPOSING COLOURS BY THE ABSORPTIVE METHOD

  A.  WHITE LIGHT
  B.  DIVIDED INTO CHROMATIC EQUIVALENTS
  C.  WHOLLY ABSORBED

COLOURS OF THE FIRST DIVISION DEVELOPED BY THE ABSORPTION OF THE THREE
COMPLIMENTARIES

  1
  2
  3

COLOURS OF THE SECOND DIVISION DEVELOPED BY THE ABSORPTION OF THE FIVE
OTHER RAYS

  4
  5
  6

  _To face page 11._]      [_Lovibond, Colour Theories._
]




CHAPTER IV.

Derivation of Colour from White Light.


The method of analysing white light into its colour constituents by
means of coloured glass absorbents of known intensity and purity, is
illustrated by the set of nine circles in Plate II, which demonstrate
that colour is developed by the absorption of the complementary colour
rays. The ratios of transmission are equal.

In this set of illustrations the circles represent light of 20 units
luminous intensity, and the absorptive value of the three glass colours
is each of 20 units, therefore the whole of the light and colour
energies are presumed to be dealt with.

In the first set of three circles, _A_ represents a beam of normal
white light. _B_ a similar beam as divided into the six colour rays,
Red, Orange, Yellow, Green, Blue and Violet in equal proportions, _C_
as wholly absorbed by Red, Yellow, and Blue glasses, each of 20 units
colour intensity.

Figures 1, 2 and 3 represent the specific action of Red, Yellow, and
Blue glass on the white light.

_Red_ absorbs Yellow, Green and Blue, transmitting Violet, Red and
Orange, developing Red only.

_Yellow_ absorbs Blue, Violet, and Red, transmitting Orange, Yellow and
Green, developing Yellow only.

_Blue_ absorbs Red, Orange and Yellow, transmitting Green, Blue, and
Violet, developing Blue only.

By this method of development, Red, Yellow or Blue, when seen alone
are visually monochromatic, although composite in structure, each
containing a group of three rays, the middle ray alone exciting the
colour sensation.

Circles 4, 5, and 6 illustrate the development of Orange, Green and
Violet from the triad groups, by intercepting the light with two glass
colours.

Circle 4, Red on Yellow, develops Orange by absorbing Yellow, Green,
Blue, Violet and Red.

Circle 5, Yellow on Blue, develops Green by absorbing Blue, Violet,
Red, Orange and Yellow.

Circle 6, Blue on Red, develops Violet by absorbing Red, Orange,
Yellow, Green and Blue.

By this method of demonstration the six colours fall naturally into
two groups. The first group includes Red, Yellow, and Blue, whilst the
second group includes Orange, Green, and Violet. The colours of the
second group, Orange, Green, and Violet, are true monochromes, each
being isolated from the light, by the absorption of the five other rays.

These illustrations deal with light and colour of 20 units
intensity;[2] as the intensity of the light here is exactly equal to
the absorptive power of the standards, no free light remains; where
the absorptive power of the colour standards is less than the light,
associated white light remains; for instance, if only one unit of
colour was developed, 19 units associated white light would remain.

[2] For description of the light and colour units, refer to chap. III,
page 9.

[Illustration: PLATE III
  _To face page 13._]      [_Lovibond, Colour Theories._
]

This method of colour development by analytical absorption is further
illustrated by Plate III, showing the effect of superimposition of the
three colours in their several combinations as intercepting a beam of
white light.

Not all lights which appear white to the vision are truly normal
white; colour may be masked by excess of luminosity, and only become
evident when the luminosity has been reduced, by placing neutral tint
standards between the light and the observer. Direct sunlight, and some
artificial lights, are instances. (Law 6 (_a_) page 8.)

On the other hand, an abnormal light may be too low for the vision to
discriminate colour. This may be observed in nature by the gradual loss
of colour in flowers, etc., in the waning intensities of evening light.
The order of their disappearance is shown in Chart I.




CHAPTER V.

Standard White Light.


The colour of a substance is determined by the ray composition of
the light it reflects, or transmits to the vision, the colour would
therefore vary with every change in the ray proportions of the incident
light; it follows that constancy in colour measurement can only be
obtained by a colourless light. Up to the present diffused daylight is
the only light which complies with the condition of ray equality.

The absolute equality of the six spectrum colours may be difficult
to establish in any light, and their constancy in equivalence under
varying light intensities may be open to argument. But, as everyday
work is carried on mainly under daylight conditions, and as the vision
is the final arbiter for colour work, theoretical questions outside the
discriminating power of the vision, need be no bar to the establishment
of a working standard white light; and in saying that diffused daylight
is normal white, it is only intended to mean: In so far as a normal
vision can determine.

Apart from any theoretical explanation it is an experimental fact, that
the abnormal rays of direct sunlight, and some artificial lights, may
be so modified by diffusion as to be available for a limited range of
colour work. In the case of diffused north sunlight, when taken from
opposite the sun’s meridian, the modification is sufficient to make it
available as a standard white light. In the case of artificial lights,
their use is, as yet, limited to visual matching (not recording) and
arbitrary comparisons.


THE BLACK UNIT.

Ideal black is total absence of light, and can only be realized as a
sensation, in the presence of light, which may however be in contrast
or in association.

The nearest approach to ideal black by contrast, is to view a hole in
a box with a blackened interior, so arranged that no light entering
the hole, can be reflected back to the vision: in this way associated
light, if not entirely absent, is reduced to a minimum and total
darkness is practically realized by the vision in contrast with the
surrounding light.

Pigmentary black viewed under diffused daylight conditions is always
associated with white light, as no substance, however black it may
be, absorbs all the impinging light; as examples, the following
measurements of three white and three black pigments were made at an
angle of 45 degrees with a light intensity of 25 units.

This is a true quantitative analysis of the 25 units of white light
after reflection from the black pigments. The black units represent
the proportion of white light absorbed, whilst the beams reflected
from the pigments consist of the colour values developed which are
associated with the unabsorbed white light.


TABLE II.

  ----------------------+--------+------+------+------+-------+------
                        |  Lime  |Blue  |Lamp  |Ivory |Zinc   | White
                        |Sulphate|Black |Black |Black |White  | Lead
  ----------------------+--------+------+------+------+-------+------
  Standard light units  |  25·0  |      |      |      |       |
  ----------------------+        |      |      |      |       |
  Black units           |        |      |      |      |       |
    (light absorbed)    |        |  9·0 |  9·2 |  9·2 |   --  |   ·08
  Violet units          |        |      |      |      |       |
    (colour developed)  |        |  2·2 |  1·4 |  1·4 |   --  |   --
  Blue  units           |        |      |      |      |       |
    (colour developed)  |        |  1·0 |  1·9 |   ·4 |   ·01 |   ·05
  Green units           |        |      |      |      |       |
    (colour developed)  |        |  --  |  --  |  --  |   --  |   ·07
  Associated white light|        | 12·8 | 12·5 | 14·0 | 24·99 | 24·80
  ----------------------+--------+------+------+------+-------+------
      Totals            |  25·0  | 25·0 | 25·0 | 25·0 | 25·0  | 25·0
  ----------------------+--------+------+------+------+-------+------

The analyses demonstrate that black is not itself an active energy
analogous to colour, but is a minus quantity distinguishable by
contrast with the original light. The reflected beam consists of the
colour developed, associated with the residue of unaltered light.

_Note._--Suitable proportions of Violet and Blue give character and
value to black, whilst Orange and Yellow are less pleasing as tending
to rustiness.




CHAPTER VI.

Qualitative Colour Nomenclature.


SIMPLE COLOURS.

The vision can separate six monochromatic colours from a beam of white
light, therefore in practical work six must be dealt with, no matter
how they may be theoretically accounted for. They naturally take the
accepted spectrum names and symbols already in use. To these are added
two other terms, Bk. to signify black, and L. for light; these terms
deal with the brightness, or dinginess, of a colour.


Simple Terms. Symbols.

    Red               R
    Orange            O
    Yellow            Y
    Green             G
    Blue              B
    Violet            V
    Black            Bk
    White             L


COMPLEX COLOURS.

The order of the association of simple colours to form complex, is
governed by two factors. The first is a physiological limitation of
the vision, which is unable to simultaneously distinguish more than two
colours, in the same beam of light, this limits the most complex colour
to two colour names. The second limitation is one of association, based
on the experimental fact, that the particular two must be adjacent in
their spectrum order, spectrum red and violet being considered adjacent
for this purpose. Under these conditions, any given colour must be
either a monochrome, or a bichrome, and all complex colours must be
bichromes. Therefore the only possible combinations are as follows:--

  Red    and Orange
  Orange  "  Yellow
  Yellow  "  Blue
  Blue    "  Green
  Green   "  Violet
  Violet  "  Red

The classified order of associating symbols for describing the
components of the whole range of distinguishable colours is set out in
the following tables:--

  -------------+-------------+------------
   Monochromes | Monochromes |Monochromes
  of a Standard|Brighter than|Duller than
   Brightness. | Standards.  |Standards.
  -------------+-------------+------------
        R.     |    R. L.    |  R. Bk.
        O.     |    O. L.    |  O. Bk.
        Y.     |    Y. L.    |  Y. Bk.
        G.     |    G. L.    |  G. Bk.
        B.     |    B. L.    |  B. Bk.
        V.     |    V. L.    |  V. Bk.
  -------------+-------------+------------

[Illustration]

The separation of the six monochromatic sensations from a point of
white light, and the formation of binary sensations by the combination
of adjacent colours, is graphically illustrated in the above diagram.

In order to make the qualitative symbols quantitative it is only
necessary to add the numerical unit value to each factor as found by
direct experiment.




CHAPTER VII.

Quantitative Colour Nomenclature.


THE GLASS STANDARD SCALES.

At an early stage of the investigation, it was found that coloured
glass gave better results than coloured solutions, and that Red,
Yellow, and Blue, were the only colours suitable for systematic
work; it was also found that any colour could be produced by their
combination. As already described arbitrary scales were first used in
many colours, but were superseded by these three, which, when graded
into scales of equivalent value, were found to cover all daylight
colours.

Upon this evidence, scales of red, yellow and blue were constructed
of glass slips, each scale being all of one colour, with a regular
variation of intensity from 0·01 to 20·0 units, equal units of the
three scales being in equivalence with each other. The dimensions of
the unit are necessarily arbitrary, but the scales comply with the
essentials of a scientific standard, in that the divisions are equal,
and the unit recoverable. The equality of the unit divisions in the
scales, is demonstrated by a system of cross-checking. The test of
colour equivalence has already been described on pages 10 and 28.

The power of recovering the unit, is by co-relation to well-known
physical colour constants, such as is easily obtained by definite
intensities of percentage solutions, of selected pure chemical
compounds in distilled water, at standard temperatures. For example,
a one per cent. solution of pure crystallized copper sulphate
C_{2}SO_{4}5H_{2}O at 60° F. when viewed in the optical instrument in
a 1-inch stratum, must be matched by a combination of Yellow 1·58 and
Blue 1·55.

The inch of distilled water itself constitutes very little of this
colour; the colour of distilled water is remarkably uniform, and might
almost be taken as a colour constant, thus: A 2-foot stratum is matched
by Yellow 0·1 and Blue 0·34, a 4-foot stratum by Yellow 1·0 and Blue
1·45.

A one per cent. solution of _Nickel Sulphate NiSO_{4}7H_{2}O, tem._ 60°
F. in a 2-inch stratum must be matched by 2·2 Blue and 2·0 Yellow units.

A one per cent. solution of _Potassium Bichromate_ K_{2}Cr_{2}O, Tem.
60° and in a 2-inch stratum after being dulled by 0·5 neutral tint
units must be matched by 34·0 yellow and 9·6 red units.


METHOD OF DEVELOPING, MEASURING AND NAMING COLOUR.

The single sensation colours, Red, Yellow and Blue, are matchable by a
single glass from the corresponding colour scale; the depth of colour
is directly indicated by the value of the glass used.

The single sensation colours, Orange, Green and Violet, are matchable
by a combination of equal units, from two of the standard scales, the
depth of colour is directly indicated by the unit value of either of
the glasses, thus: 2·0 Blue + 2·0 Red develop 2·0 units Violet.

A given neutral grey is matchable by a combination of equal units from
the three standard scales, the depth of grey, is directly indicated by
the unit value on either of the glasses used, thus:--

3·0 Red + 3·0 yellow + 3·0 blue develop 3·0 units neutral tint.

The complex colour sensations, red and yellow oranges, yellow and
blue greens, blue and red violets are matchable by unequal glasses
from two of the standard scales; the colour developed is not directly
indicated by the unit value of the glasses, but is recorded by means of
an equation, the first half of which contains the separate values of
the glasses used, and the second half the names and the depth of the
colours they transmit. For instance--

The equation of a colour matched by 17·0 red and 2·6 blue units, is as
follows:--

    Standard Glasses.   Colour Developed.
       Red.   Blue.      Violet.  Red.
       17·0 +  2·6    =    2·6  + 14·4

The colour developed is a red violet in these proportions.

A colour matched by

    Standard Glasses.   Colour Developed.
       Red.  Yellow.     Orange. Red.
       10·0 + 3·0     =    3·0 + 7·0

The colour developed is a red orange in these proportions.

A colour matched by

    Standard Glasses.      Colour Developed.
     Yellow.   Blue.        Green.  Yellow.
       3·0  +  1·5     =     1·5  +  1·5

The colour developed is a yellow green in these proportions.

A colour matched by

    Standard Glasses.      Colour Developed.
      Blue.    Red.         Blue.   Violet.
       6·0  +  1·8     =     4·2  +  1·8

The colour developed is a blue violet in these proportions.

The standard glass colours are necessarily of a given brightness, and
colours for measurement may be either brighter, or sadder than the
standards.

A given complex colour of less than glass standard brightness, is
matchable by unequal numbers from the three standard scales; the
smallest unit value always represents the “black,” or neutral unit
factor. The equation is as follows:--

A colour matched by

      Standard Glasses.        Colour Developed.
    Red.  Yellow.  Blue.   Neutral Tint. Green. Blue.
    1·0  +  3·0  +  9·0  =      1·0   +   2·0  + 6·0

The colour is a blue green, in the proportion of six to two, saddened
by one of neutral tint.

A given complex colour of greater brightness than the glass standards,
is first dulled by the interception of neutral tint units, until
measurable in the manner described above; the intercepting glasses
represent the unit value of excess of brightness, and is shown in the
equation as light units, for instance--

     Standard Glasses.             Colour Developed.
    Neutral Tint. Yellow. Blue.    Light. Green. Yellow.

              1·5 + 7·5 + 0·5    =   1·5 + 0·5 + 7·0

The colour is a yellow green in the proportions of 7·0 of yellow, to
0·5 of green, and 1·5 brighter than the standards.

Every daylight colour being thus measurable by a suitable combination
of standard glasses, with or without the addition of a Light, or a
Neutral Tint factor, it follows that any colour can be described both
qualitatively, and quantitatively, in terms of the colour sensations
yielded by the standard glasses and their combination. The distinct
colour sensations are those, which, by common consent are known as Red,
Yellow, Blue, Orange, Green and Violet, and they are yielded by single
glasses, or by pairs as already described; all colours therefore fall
into the following categories:--

_A._--Single colour sensations:--

1. Transmitted by single glass standards:

                                Red.
                                Yellow.
                                Blue.

2. Transmitted by equivalent pairs of standard glasses:

                                Orange.
                                Green.
                                Violet.

_B._--Double colour sensations transmitted by unequal pairs of standard
glasses.

Red orange, transmitted by unequal units of red and yellow, red
preponderating.

Yellow orange, transmitted by unequal units of red and yellow, yellow
preponderating.

Yellow green, transmitted by unequal units of yellow and blue, yellow
preponderating.

Blue green, transmitted by unequal units of yellow and blue, blue
preponderating.

Blue violet, transmitted by unequal units of blue and red, blue
preponderating.

Red violet, transmitted by unequal units of blue and red, red
preponderating.

_C._--Any of the above colours with the addition or subtraction of
neutral tint.

Neutral tint itself, is transmitted by a combination of equal units
of the standard glasses, thus three units red, yellow and blue, when
superposed, transmit three units neutral tint.


EXAMPLES.

Three units red, of standard brightness, completely describes a colour
matched by a red glass of three units, and is denoted

                                R. 3·0

Three units red saddened by one neutral tint, completely describes a
colour matched by a red glass standard of four units red, combined with
a blue and yellow of one unit each, and is denoted

                           R. 3·0 + N.T. 1·0

A given red of three units, which is one unit brighter than standards,
after having been saddened by one unit each of red, yellow and blue,
is matched by three units of red and is correctly described by

                          Red 3·0 + Light 1·0

Three units of violet, of standard brightness, is matched by a red and
a blue glass of three units, and is correctly described by

                                V. 3·0

Three units of orange, of standard brightness, is matched by a red and
a yellow glass of three units, and is correctly described by

                                O. 3·0

A binary red violet of standard brightness, in which red preponderates
by one unit, is matched by four units red, and a blue of three units,
and is correctly described by

                            R. 1·0 + V. 3·0

A binary red orange, of standard brightness, in which orange
preponderates by three units, is matched by red four and yellow three
units, and is correctly described by

                            R. 1·0 + O. 3·0

A red orange, of less than standard brightness by one unit, in which
orange preponderates by three units, is matched by a red five, yellow
four, blue one, and is correctly described by

                      R. 1·9 + O. 3·0 + N.T. 1·0

A red violet, in which red preponderates by one unit, and is one unit
brighter than standard, is first dulled by one unit red, yellow and
blue, and then matched by four red and three blue, and is correctly
described by

                      R. 1·0 + V. 3·0 + Light 1·0

A red orange, in which red preponderates by one unit, and is one unit
brighter than standard, is first dulled by one red, yellow and blue,
and then matched by four red, and three yellow, and is correctly
described by

                      R. 1·0 + O. 3·0 + Light 1·0




CHAPTER VIII.

The Colour Scales.


A normal vision under ordinary conditions, has no hesitation in
correctly naming the sensations produced by the triad groups red,
yellow and blue, or by the single rays orange, green and violet. It
can also correctly describe a complex colour sensation, by naming
the two associated colours, such as red orange, yellow orange, blue
green, blue violet, etc.; but when called upon to decide differences of
colour depth, it can only do so by using arbitrary terms of no precise
scientific value, such as light, medium, dark, etc.

This deficiency is because the vision has in itself no arrangement for
the quantitative definition of colour depth. This want can only be met
by co-relating colour sensations, to some physical colour constants.

This co-relation has now been effected by a series of glass standard
colour scales, which are numerically graded for colour depth, the
scales themselves being colour constants by co-relation to percentage
solutions, of such coloured chemicals, as copper sulphate, nickel
sulphate, potassium permanganate, etc. These substances as well as
many others, are always available for checking the constancy of the
scales, or for recovering the unit if lost.

As already mentioned, the system of taper scales proved to be useless
for the purpose, not only because the rate of colour increase was never
in proportion to the rate of thickness increase, but also because no
two substances are equal in this respect, each having a rate specific
to itself.

The prismatic spectrum colours were not available for several reasons,
first as being unsuitable for critical comparisons under daylight
conditions, as being too weak except “in camera”; also they were found
to be too crowded for the separation of a working area of monochromatic
colour, and some corrections would have been necessary for variation
in the refractions of different colour rays. This is more fully
dealt with under the heading of The Spectrum in relation to Colour
Standardization, page 36.


THE EQUIVALENCE OF THE COLOUR SCALES.

The method employed for obtaining equality of the unit divisions, and
colour equivalence between the different scales was as follows:--

Two slips of red glass in a light shade were made exactly equal in
colour, and considered as initial units; these were then superimposed
and matched by a single glass, which was then considered as of two
units, this and one of the initial units were superimposed, and matched
by a single glass of three colour units, and so on, until a progressive
red scale was constructed, ranging in intensity from ·01 to 20·
units.[3]

[3] It was found that the superimposition of two glasses did not
visually disturb equivalence, therefore only two glasses were used for
each observation in constructing the scales.

The yellow and blue scales, were similarly constructed, taking care
that their similar unit values were in colour equivalence with the red
units, the test of equivalence being, that when equal units of the
three scales were superimposed against a normal white light, a neutral
grey was transmitted, in which no trace of colour could be perceived by
the common consent of the whole staff of trained observers.

The scales were then considered as in colour equivalence with each
other. The system of cross-checking was so elaborate, that after the
equivalence of the first unit was established, nearly four years was
occupied in the work before the scales were passed as satisfactory.

It may be urged that the unit is arbitrary, but this applies also
to the unit of any other standard scale; it is sufficient that the
essentials of a philosophic scale are complied with, in that the
divisions are equal, and the unit recoverable.

[Illustration: PLATE IV COMPARISON CURVES OF HEALTHY HUMAN BLOOD WITH
THE BLOOD OF LOWER ANIMALS.
  _To face page 31._]      [_Lovibond, Colour Theories._
]




CHAPTER IX.

Colour Charts.


A colour chart is constructed by placing two colour scales at right
angles to each other, with their zeros at the angle.

A measured simple colour, finds its position directly on its
corresponding colour scale at the point of its measured value.

A measured complex colour, finds its position within the angle, at that
point where perpendiculars drawn through the two colour values meet.

The above statements are complete only for colours of standard
brightness, should the colour be brighter or duller than standards,
a light factor is necessary, the value of which is furnished by the
measurement itself, and must be written in numerals near the colour
point.

By this method the chart position of even the most complicated colour
is indicated by a single point which is determined by the analytical
value of the composing factors.


EXAMPLES.

  Simple Colour of |   Complex Colour
      Standard     |    of Standard
    Brightness.    |    Brightness.
                   |
      3· Red.      | 6· Blue, 10· Violet.

  Simple Colour    | Complex Colour
   Brighter than   |  Duller than
  Standards.       |   Standards.
                   |
    7· Yellow,     | Red 6, Orange 5,
     Light 2·      |     Black 2.

The number of complex colour charts is limited to the six represented
in Fig. 1 as lying in their order on a continuous spectrum. The red and
violet mixtures having no visible spectrum position are represented in
the ultra violet. The ordinates of the charts are made by erecting the
overlying red, yellow and blue scales as perpendiculars.

[Illustration: Fig. 1.]

The information to be obtained by charting measured colour is more
extensive than appears at first sight, as by varying the character
of the co-ordinates, and charting suitable series of measurements,
new fields of investigation are opened, thus throwing light on some
hitherto obscure questions, of which the following are some instances.


SPECIFIC COLOUR.

It has sometimes been assumed that colour increase was in direct ratio
to intensity increase, but this is never the case, each substance has
its own rate, specific to itself. It is conceivable that the colours
of two substances may coincide at one point, but as their densities
increase, or decrease, their rates of change vary.

The term “Specific Colour” is based on the experimental fact, that the
colour of a given substance is constant, so long as the substance
itself and the conditions of observation, remain unaltered. During
experimental work a sufficient number of instances have accumulated to
warrant the writer in advancing and using the term “Specific Colour” as
describing a new natural law, as rigid in its application as that of
“Specific Gravity” or “Specific Heat.”

[Illustration: PLATE V ABSORPTION CURVES OF FIVE COLOUR CONSTANTS.
  _To face page 33._]      [_Lovibond, Colour Theories._
]

When this principle is applied to the measurement of regularly
increasing thicknesses, curves of colour changes can be established,
which are specific for the substance in question, and afford a certain
means of identifying similar substances in future. This is effected
by varying the nature of the co-ordinates, making the ordinates
to represent the tintometrical scale of colour units irrespective
of colour, whilst the abscissae represent the scale of increasing
thicknesses. Then by plotting the separate factors of each measurement
according to their unit values, a series of curves is established,
specific to the substance in question, and applicable to none other.

We have now two systems of charting colour, in the first, the complete
sensation is represented by a single point, as in Plate IV. In the
second, each factor is represented by a separate point, and by
connecting points of similar colours, a series of curves is established
which represents a quantitative analysis of the progressive colour
development, as in Plate V.




CHAPTER X.

Representations of Colour in Space of Three Dimensions.


The relations of the different colours to one another, and to neutral
tint are, perhaps, best represented to the mind by a solid model, or
by reference to three co-ordinate axes, as employed in solid geometry
(_see_ Fig. 2).

[Illustration: Fig. 2.]

Let the three adjacent edges OR, OB, OY, of the above cube be three
axes, along which are measured degrees of Red, Yellow and Blue
respectively, starting from the origin O. Every point in space on
the positive side of this origin will then represent a conceivable
colour, the constituents of which in degrees of red, yellow and blue
are measured by the three co-ordinates of the points. Pure reds lie all
along the axis OR, pure yellows on the axis OY, and pure blues on the
axis OB.

All normal oranges, normal greens, and normal violets lie on the
diagonals of the faces of the cubes OO^1, OG, OV respectively.

Pure neutral tints lie on the diagonal ON of the cube, equally inclined
to the three principal axes.

Red violets will be found on the plane ROB, between OV and OR.

Blue violets on the same plane between OV and OB.

“Saddened” red violets all within the wedge or open space enclosed by
the three planes, whose boundaries are OB, OV, ON.

The other colours, red and yellow oranges, blue and yellow greens, pure
and saddened, are found in corresponding positions in relation to the
other cases.[4]

[4] This method of illustration was suggested by Dr. Herbert Munro.




CHAPTER XI.

The Spectrum in relation to Colour Standardization.


The spectrum has naturally been considered as a suitable source for
colour standards, but the power of analysing has disclosed some
difficulties, which have yet to be overcome.

Concerning the prismatic spectrum, there has always been a difficulty
in apportioning the different colours to specific areas, and further,
before this spectrum is available for colour standardization, some
method of correction for the unequal distribution of colours must be
devised.

Neither of these difficulties occur in the use of the diffraction
spectrum, where the pure colours are apportioned by Professor Rood from
A to H in the manner shown in table on next page.

Professor Rood further divides the spectrum from A to H into 100 equal
divisions, allotting 20 unit divisions of 72,716 wave lengths to the
space between each two colour lines. This allots a space of 3,635 W.L.
to each unit division, as shown in Table III.

TABLE III.

  -----------+-----------------------+-----------+--------+--------
             |                       |   No. of  |        |
             |                       |    Wave   |        |
             |                       |  Lengths  |        | W.L.K.
             | Wave Length Position. |    from   |Division|   per
             |                       |   Colour  |        |Division
             |                       |  between  |        |
             |                       |   each.   |        |
  -----------+-----------------------+-----------+--------+--------
  760,400 A. |Red            760,400 |           |        |
             |-----------------------+   72,717  | == 20  |  3,635
             |Orange         687,683 |           |        |
             |-----------------------+   72,716  | == 20  |  3,635
             |Yellow         614,967 |           |        |
             |-----------------------+   72,716  | == 20  |  3,635
             |Green          542,251 |           |        |
             |-----------------------+   72,716  | == 20  |  3,635
             |Blue           469,535 |           |        |
             |-----------------------+   72,716  | == 20  |  3,635
  396,819 H. |Violet         396,819 |           |        |
  -----------+-----------------------+-----------+--------+--------
  363,581    |Total W.L. between A. & H. 363,581 |   100  |
  -----------+-----------------------------------+--------+--------

Having provided equal wave length positions for the six pure colours,
the intermediate colours are necessarily binaries in definite
proportions, accounted for by a regular overlapping of two bounding
colours in opposite directions from zero to 20, as shown in the
following table from Red to Orange, representing the space between
these two pure colours.

  Red  20 19 18 17 16 15 14 13 12 11 10  9  8  7  6  5  4  3  2  1  0  W.L
  W.L                                                                  687,
  760,  0  1  2  3  4  5  6  7  8  9 10 11 12 13 14 15 16 17 18 19 20   683
   400 -------------------------------------------------------------- Orange.
       20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
       ==============================================================

It follows, that apart from the six monochromes, all spectrum complex
colours in a single wave length must be binaries, whose united values
equal 20.

On comparing Professor Rood’s scales of divisions with those of the
tintometrical scales already described, they appear to coincide in
several particulars, for instance:--

The monochromes correspond both in number and in name.

Their positions in the scales correspond.

Their unit divisions are equal in number, and in dimensions.

Their colour positions correspond, when an artificial tintometrical
spectrum is made by regularly overlapping monochromes.

It follows that when the two scales are superimposed as in Plate V.,
showing similar monochromes as lying in the same perpendicular, the
same wave length numbers apply to both; concerning the dimensions
between the monochromes, the spaces occupied by 72,716 wave lengths
between the spectrum monochromes, also represent similar spaces in the
tintometrical scales, and one-twentieth of this 3,635 represents the
space of a single unit in each case.

In connexion with these co-related dimensions, some information is
obtainable bearing on the limitation of a monochromatic vision for
discriminating small colour differences. Under ordinary daylight
conditions, the unit in the lighter shades of the tintometrical
scale is divided into 100 fractional parts, each fraction therefore
represents a space occupied by thirty-six wave lengths in the spectrum
scale. This may be near the limit of dimension for monochromatic vision
in such a gradually changing colour scale, as that of the spectrum, and
may be some guide as to suitable slit areas in the synthetical building
up of complex coloured light.

[Illustration: PLATE VI SIX COLOUR CHARTS IN ONE OR ANOTHER OF WHICH
ANY SIMPLE OR COMPLEX COLOUR FINDS A DEFINITE POSITION.
  _To face page 39._]      [_Lovibond, Colour Theories._
]

In Plate VI. are shown the six tintometrical colour charts, as lying
in their order on the tintometrical spectrum, illustrating that any
measured colour factor lies in a perpendicular drawn through both
spectra, and occupying the same wave length position, and may therefore
be designated by that wave length number.

This explanation is not intended to convey that the colour energies
do not really overlap beyond the boundaries of the dual combinations,
but only that the vision is unable to distinguish as colour, such
overlapping if it exists.


POINTS OF DIFFERENCE.

On further comparisons of the two scales there are some points of
difference which have a bearing on their values as colour standards.

There is a variation in the length of the two scales, the spectrum
terminating at H, whilst the tintometrical scale is extended to a
sixth division in the region of the ultra violet, showing overlapping
combinations of Red and Violet, strictly analogous to the overlapping
binaries in the other five sections.

These red and violet combinations constitute one-sixth of the cycle of
distinguishable colours, and cannot be omitted in any system of colour
standardization, therefore their absence in the continuous spectrum is
a drawback.

A second drawback, is the limited number of spectrum complex colours,
in consequence of each colour being blended only with overlapping
colour value, which lies in its own wave length, whereas in nature
each colour may be blended with any value of the overlapping colour. In
the tintometrical standards, similar effects are obtained by changing
the value of the graded slips.

It is true, that complex colours other than those in the same wave
length, may be developed by blending two colours from different parts
of the spectrum, but the ray proportions of colours so produced, are
necessarily more complex than those developed by specific absorption;
the first being a method of synthesis towards complexity, and the
second a method of analysis towards simplicity, and although two
colours so produced may be similar in name, red for instance, they
must differ in character. This view may tend to reconcile some of the
theoretical differences between Scientists and Artists.


THE ULTRA VIOLET DIVISION.

The complete range of daylight colours not being fully comprised in a
continuous spectrum, may be considered as a cycle of radiant energies,
sensitive to the vision as colour, which can be represented as a
circle as in Plate VII. The outer and broken circle represents a bent
spectrum, the unoccupied division corresponding in position with that
of the red and violet mixtures in the complete cycle.

This arrangement does not alter the relative positions of the
Fraunhoper lines A, B, C, D, E, F, G and H in reference to either
scale, but, it theoretically breaks that sequence of the successive
wave lengths in the Red Violet which holds good in the other five
divisions from A to H.

[Illustration: PLATE VII
  _To face page 40._]      [_Lovibond, Colour Theories._
]

In order to theoretically avoid this juxtaposition of wave length
contrast, it is only necessary to imagine that the violet energy beyond
H in the ultra violet, is overlapped by the infra red energy of a
succeeding spectrum, filling this section with a series of overlapping
binaries analogous in wave length sequence to that of the other
sections.


A RESIDUAL RED RAY.

Apart from the colours of everyday life there is, in sunlight and
most direct artificial lights, an additional red energy which differs
materially from the red energy in diffused daylight.

It was first noticed whilst establishing the colour equivalence of the
tintometrical light unit, by developing a red sensation which disturbed
constancy of reading under certain conditions of light.

So far as the writer knows, this energy has never been investigated as
separate from the other spectrum red. The following observations must
be considered as tentative only.


SOME PROPERTIES.

It does not obey the laws of absorption which govern the red of
diffused daylight. When the six transparent pigmentary colours are
illuminated by direct sunlight, and viewed through a sufficient number
of Neutral Tint units, the colours all disappear, all appearing red
alike, with only differences in luminosity.

The spectrum position of this red energy is in the A. B. region, and
further interception by Neutral Tint whilst narrowing the band,
intensifies the colour, until obstructed by the large number of
intercepting glass surfaces.

It has no photographic action on the six sensitised papers dealt with
in the photographic section.


LIGHT INTENSITIES.

The apparatus for determining the unit values of light intensities
in the following series of measurements, consisted of a conical
rectangular hopper tapering from 2 feet to 2 inches square. This was
adapted so that the light from the small end, commanded the stage of
the optical instrument sufficiently close to cut off outside light.
The wide end facing a north sky was adapted with sliding shutters, to
regulate the area of incident light; of the six water-colour pigments
which nearest corresponded to the standard colours, washed to their
full depth on Whatman’s paper, six measurements were made. These
measurements are shown in Table IV, and classified in Table V.

It will be noted that the readings are constant for all the colours
between 16 and 26 units, except a variation of light ·15 in the 24-inch
opening, which is in effect as if the cone was not present, and ·2 in
the 8-inch area of orange.

    Note.--Experiments in this branch give some information
    relating to the perception of colour under daylight conditions,
    by limiting the range of intensities within which colour can
    be distinguished and differentiated, whilst their separate
    photographic action (page 48) suggests the impression that
    colour phenomena, outside these limits, may be a physiological
    expression of widely varying underlying energies.


TABLE IV.

  -------------+---------+----------+--------+--------+---------+-------
               | Square  |          |        |        |         |
  Pigment.     | Inches  | Light    | Black. |  Red.  | Orange. |
               |Aperture.|Intensity.|        |        |         |
  -------------+---------+----------+--------+--------+---------+-------
  Carmine      |      2  |     10   |   ·5   |   20·2 |    ·3   | ----
    "          |      4  |     11   |   ·5   |   19·1 |    ·4   | ----
    "          |      6  |     14   |   ·46  |   18·95|    ·59  | ----
    "          |      8  |     16   |  ----  |   16·9 |   1·1   | ----
    "          |     10  |     20   |  ----  |   16·9 |   1·1   | ----
    "          |     12  |     22   |  ----  |   16·9 |   1·1   | ----
    "          |    Open |     26   |  ----  |   16·9 |   1·1   | ----
  -------------+---------+----------+--------+--------+---------+-------
               |         |          |        | Yellow |         |
  Lemon Yellow |      2  |     10   |  ----  |    6·9 |    ·1   | ----
    "     "    |      4  |     11   |  ----  |    6·9 |    ·1   | ----
    "     "    |      6  |     14   |  ----  |    6·9 |    ·1   | ----
    "     "    |      8  |     16   |  ----  |    7·0 |   ----  | ----
    "     "    |     10  |     20   |  ----  |    7·0 |   ----  | ----
    "     "    |     12  |     22   |  ----  |    7·0 |   ----  | ----
    "     "    |    Open |     26   |  ----  |    7·0 |   ----  | ----
  -------------+---------+----------+--------+--------+---------+-------
               |         |          |        |  Blue. | Violet. |
  Cobalt Blue  |      2  |     10   |  ----  |   11·5 |   ----  | ----
    "     "    |      4  |     11   |  ----  |   11·5 |   ----  | ----
               |         |          |        |        |  Green. |
    "     "    |      6  |     14   |  ----  |   10·7 |    ·2   | ----
               |         |          |        |        |  Violet.|
    "     "    |      8  |     16   |  ----  |   10·5 |    ·5   | ----
    "     "    |     10  |     20   |  ----  |   10·5 |    ·5   | ----
    "     "    |     12  |     22   |  ----  |   10·5 |    ·5   | ----
    "     "    |    Open |     26   |  ----  |   10·5 |    ·5   | ----
  -------------+---------+----------+--------+--------+---------+-------
               |         |          |        |   Red. | Orange. | Light.
  Chrome Orange|      2  |     10   |  ----  |    3·4 |   6·0   | ----
    "      "   |      4  |     11   |  ----  |    3·4 |   6·0   | ----
    "      "   |      6  |     14   |  ----  |    3·0 |   6·2   | ----
    "      "   |      8  |     16   |  ----  |    3·0 |   6·0   |  ·05
    "      "   |     10  |     20   |  ----  |    3·2 |   6·0   |  ·05
    "      "   |     12  |     22   |  ----  |    3·2 |   6·0   |  ·05
    "      "   |    Open |     26   |  ----  |    3·2 |   6·0   | ----
  -------------+---------+----------+--------+--------+---------+-------
               |         |          |        |Yellow. |  Green. |
  Emerald Green|      2  |     10   |  ----  |   ·2   |    6·4  |  ·05
    "       "  |      4  |     11   |  ----  |  ----  |    6·4  |  ·05
    "       "  |      6  |     14   |  ----  |  ----  |    6·4  |  ·05
    "       "  |      8  |     16   |  ----  |  ----  |    6·6  | 2·0
    "       "  |     10  |     20   |  ----  |  ----  |    6·6  | 2·0
    "       "  |     12  |     22   |  ----  |  ----  |    6·6  | 2·0
    "       "  |    Open |     26   |  ----  |  ----  |    6·6  |  ·05
  -------------+---------+----------+--------+--------+---------+-------
               |         |          |        |  Red.  | Violet. |
  Mauve        |      2  |     10   |  ----  |  3·0   |    7·4  | ----
    "          |      4  |     11   |  ----  |  3·0   |    7·4  | ----
    "          |      6  |     14   |  ----  |  3·0   |    7·2  | ----
    "          |      8  |     16   |  ----  |  2·8   |    7·2  | ----
    "          |     10  |     20   |  ----  |  2·8   |    7·2  | ----
    "          |     12  |     22   |  ----  |  2·8   |    7·2  | ----
    "          |    Open |     26   |  ----  |  2·8   |    7·2  | ----
  -------------+---------+----------+--------+--------+---------+-------


TABLE V.

COLOURED SURFACES

Table of Varying Luminous Intensities

  -------+------+----------------+----------+------------------
         |      |      Red.      |  Yellow. |     Blue.
         |      +----------------+----------+------------------
  Inches |Light |   “Carmine.”   | “Lemon.” |   “Cobalt.”
  Square.|Units.|                |          |
         |      +-----+-----+----+----+-----+-----+-----+------
         |      |  R. | Or. |Blk.| Y. | Or. | B.  | Vi. | Blk.
  -------+------+-----+-----+----+----+-----+-----+-----+------
       2 |  10  |20·2 |  ·3 | ·5 | 6·9|  ·1 |11·5 | ----| ----
       4 |  14  |19·1 |  ·4 | ·5 | 6·9|  ·1 |11·5 | ----| ----
       6 |  14  |18·95|  ·59| ·46| 6·9|  ·1 |10·7 |  ·2 |  ·1
       8 |  16  |16·9 | 1·1 |----| 7·0| ----|10·5 |  ·5 | ----
      10 |  20  |16·9 | 1·1 |----| 7·0| ----|10·5 |  ·5 | ----
      12 |  22  |16·9 | 1·1 |----| 7·0| ----|10·5 |  ·5 | ----
    Open |      |     |     |    |    |     |     |     |
      24 |  26  |16·9 | 1·1 |----| 7·0| ----|10·5 |  ·5 | ----
  -------+------+----------------+----------+------------------
  -------+------+----------------+----------------+------------
         |      |     Orange.    |     Green.     |  Violet.
         |      +----------------+----------------+------------
  Inches |Light |    “Chrome.”   |   “Emerald.”   |“Fr. Mauve.”
  Square.|Units.|                |                |
         |      +----+----+------+----+----+------+-----+------
         |      |Or. | R. |Light.| Gr.| Y. |Light.| Vi. | R.
  -------+------+----+----+------+----+----+------+-----+------
       2 |  10  | 6· | 3·4|  ·05 | 6·4| ·2 |  ·05 | 7·4 | 3·
       4 |  14  | 6· | 3·4|  ·05 | 6·4| ·2 |  ·05 | 7·4 | 3·
       6 |  14  | 6·2| 3· |  ·05 | 6·4|----|  ·05 | 7·2 | 3·
       8 |  16  | 6· | 3· | ---- | 6·6|----|  ·2  | 7·2 | 2·8
      10 |  20  | 6· | 3·2| ---- | 6·6|----|  ·2  | 7·2 | 2·8
      12 |  22  | 6· | 3·2| ---- | 6·6|----|  ·2  | 7·2 | 2·8
    Open |      |    |    |      |    |    |      |     |
      24 |  26  | 6· | 3·2| ---- | 6·6|----|  ·05 | 7·2 | 2·8
  -------+------+----------------+----------------+------------




CHAPTER XII.

The Physiological Light Unit.


DIFFUSED LIGHT.

The physiological values of light intensities determined by the
absorptive method, differ in some respects, from the intensities based
on the inverse ratio of the squares of distance between the shadows of
two lights.

However valuable this method of calculating light intensities may
be from a mathematical point of view, it does not express the
physiological appreciation of light differences.

The dimensions of the light unit used in the following experiments have
already been described.

This method cannot deal exhaustively with intense direct lights, on
account of the presence (activity) of the disturbing red ray which
prevents total absorption. Such lights must first be modified by
intercepting media of known diffusive value, or by reflection from a
white surface.

One object of these experiments was to obtain more insight into the
physiological conditions of light, as bearing on the question of
standardization.

The first two experiments are records of intensity changes by time,
in Morning and Evening light, and are of interest, as bearing on the
lowest luminosities for reading, for viewing objects at different
distances, and for defining the limits at which colours visually
disappear. The measurements are marked in neutral tint units and
plotted in curves in Charts 1 and 2.

The numbers on the single curve in the Morning chart represent total
absorption of the direct light 20 degrees above the horizon. The upper
curve in the Evening chart also represents the direct light, whilst
the under curve represents the light values as reflected from a lime
sulphate surface; except in the case of the reading notes when it
represents the printed paper surface. The difference between the two
curves is the loss of light incident on reflection, but this must not
be rigidly interpreted for all cases, as there is reason for supposing
it varies with different lights.


DIRECT LIGHTS.

In measuring the physiological intensity of direct lights, the presence
(activity) of the unabsorbable red ray, prevents their being dealt
with directly by the absorptive method. Such lights can, however, be
made measurable by a sufficient diffusion, as already explained in the
case of direct sunlight, the proportion of diffusion required, being
more or less according to the intensity of the light; in the following
examples, one reflection from a white surface or from the ordinary
grease spot arrangement, was found to be sufficient.

    Note.--Light reflected from grease is not above suspicion, it
    being governed by the law of specific absorption already dealt
    with.

[Illustration: Chart 1.

Evening Light March 18^{th}. 1906.

  _Upper Curve 20° above Horizon
  Lower Curve as Reflected from a
  1 Foot Square Lime Sulphate Screen_
]

[Illustration: Chart 2.

Morning Light Dec^r. 17^{th}. 1907.

_20° above Horizon_]

[Illustration: Chart 3.

Luminous Intensities of _1, 2 & 3 Standard Candles_.]

[Illustration: Chart 4.

Luminosity of Gas from Burner

_Reduced to Equal 1, 2 & 3 Candles at 1 Foot._]

[Illustration: Chart 5.

Luminosities of Paraffin Lamp

_Reduced to 1, 2 & 3 Candles at 1 Foot._]

The experiments were carried out on a home-made twelve-foot photometer,
with the usual protected lantern at each end, one being removed for
present purposes. The grease spot carrier was replaced by a one-foot
square diaphragm, with a standard white surface; this travelled the
whole length of the photometer at right angles to the light, and the
readings made at one-foot intervals at an angle of 45 degrees, 10
inches distance from the white surface.

Charts 3, 4 and 5 deal with experiments, with one, two and three
standard candles of the London Gas Referees. The curves represent
the physiological rate of declining luminosities by distance. Some
characteristic differences from other lights are brought together in
Charts 4 and 5. The slight irregularities in the curves are probably
due to the readings being made at half unit intervals. These acting
sometimes in opposite directions, fully account for want of symmetry in
the curves.

A noticeable feature in these experiments is the small amount of
physiological luminosity added by each successive candle to the
first. Theoretically, if one candle equals 21 units intensity, two
should equal 42, and three 63, whereas the physiological additions of
luminosity are not only much less, but vary with different luminous
intensities, as will be seen by the following comparisons:--

               1        2        3
             Candle  Candles  Candles  Total.

  Theoretical   21  +  21    +  21    =  63

  Physiological 21  +   3    +   6    =  30

Chart 4 represents the Luminosity of gas from a batswing burner
reduced to one, two and three candle power at one foot distance.

               1        2        3
             Candle  Candles  Candles  Total.

  Theoretical   21  +  21    +  21    =  63

  Physiological 21  +   3    +   7    =  31

Chart 5 represents the Luminosity of a hand Paraffin Lamp similarly
reduced.


               1        2        3
             Candle  Candles  Candles  Total.

  Theoretical   21  +  21    +  21    =  63

  Physiological 21  +   3    +   6    =  30


PHOTOGRAPHIC ENERGIES OF DIFFERENT RAYS

The following experiments are preliminary only, and were undertaken to
determine the relationship of the several colours of the tintometrical
scales, to their associated photographic values, under different
conditions of light and times of exposure, the end in view being the
hope of standardizing screens, papers and impressions.

The standardized colours act as selective light absorbents on the same
principle as screens for trichromatic colour work, but differ from
these in their having a definite standard of colour depth and colour
purity.

Work of this character requires paper of a known degree of
sensitiveness, but on inquiry it was found that no reliable standard
had as yet been established. On this, six makes of “white” paper were
purchased in the open market and submitted to exposures under the
following conditions:--

Six slips of the sensitized papers were covered by a thin metal plate,
pierced by six rows of apertures, a complete row lying over each
sample of paper. The rows contained seven apertures each, one being
left uncovered to receive the full energy of the impinging light. The
remaining six were covered respectively by a Red, Orange, Yellow,
Green, Blue or Violet standardized screen of 15 units colour intensity;
the whole was fitted into a suitable exposure frame. Many exposures
were made, from which the four following were selected:--

  No. 1. 20 min. exposure to a dull sky.
   "  2. 10  "      "     " bright sunlight.
   "  3. 20  "      "     "          "
   "  4. 30  "      "     "          "

The results are arranged in Tables VI and VII.

Table VII contains results of different exposures under sunlight
conditions.


TABLE VI.

DULL SOUTH LIGHT.

20 Minutes’ Exposure on White Sensitized Papers.

  -----+-----------------+-----------------+------------------
   Pap-|                 |                 |
   ers |   OPEN SCREEN.  |   RED SCREEN.   |  ORANGE SCREEN.
       |                 |                 |
  -----+-----------------+-----------------+------------------
       | Blk.  Or.  Red. | Blk.  Or.  Yel. | Blk.  Or.  Red.
    1  | 7·8   4·2  6·0  | 2·0   4·8  3·0  | ----   ·3   ·2
       |                 |            Red. |
    2  | 6·0   5·0  5·5  | 1·9   3·1   ·4  | ---- ----  ----
       |                 |            Yel. |
    3  | 7·8   3·2  7·0  | 2·7   4·7  3·0  | ---- ----  ----
       |                 |            Red. |
    4  | 7·2   4·3  6·0  | 2·2   3·2   ·2  | ---- ----  ----
    5  | 5·8   7·2  4·0  | 1·9   2·3   ·8  | ---- ----  ----
    6  | 5·6   7·4  4·0  | 1·8   2·6    6  | ---- ----  ----
  -----+-----------------+-----------------+------------------

  -----+-----------------+-----------------+-----------------+------------------
   Pap-|                 |                 |                 |
   ers | YELLOW SCREEN.  |  GREEN SCREEN.  |  BLUE SCREEN.   |   VIOLET SCREEN.
       |                 |                 |                 |
  -----+-----------------+-----------------+-----------------+------------------
       | Blk.  Or.  Red. | Blk.  Or.  Red. | Blk.  Or.  Red. | Blk.  Or.  Red.
    1  | 2·0   3·0  1·6  | ----  ---- ---- |  3·9  7·6   3·5 |  ·2    ·4   1·0
       |                 |                 |            Yel. |
    2  |  ·4    ·4  1·0  | ----  ---- ---- |  4·3  9·2   4·5 |  ·2    ·8    ·8
       |                 |                 |            Red. |
    3  | 1·2    ·5   ·8  | ----  ---- ---- |  3·7  9·3   2·0 |  ·7    ·6    ·9
       |                 |                 |            Yel. |
    4  | 1·2    ·1  1·2  | ---- ----  ---- |  3·4  1·1   1·0 |  ·7    ·7    ·9
    5  | 1·0    ·3   ·3  | ---- ----  ---- |  3·3  8·7   2·0 |  ·3    ·3   1·2
       |                 |                 |            Red. |
    6  |  ·2    ·3   ·4  | ---- ----  ---- |  3·6  8·9   1·5 |  ·4    ·2    ·9
  -----+-----------------+-----------------+-----------------+------------------


TABLE VII.

BRIGHT SUNLIGHT (South), 18--9--12.

10 Minutes’ Exposure on White Sensitized Papers.

  ---+-------------+---- --------+--------------+---------------
  NO.| OPEN SCREEN.| RED SCREEN. |ORANGE SCREEN.|YELLOW SCREEN.
  ---+-------------+-------------+--------------+---------------
     |Blk. Or. Red.|Blk. Or. Yel.|Blk.  Or. Red.|Blk.  Or. Red.
   1 | 8·4 1·6  6·5|2·8  6·8  1·9| ·34 1·41  ·55| 2·3  7·1 --
   2 | 8·2 2·0  6·3|2·7  4·7  3·6|--   --   --  |  ·8  1·9  ·70
   3 | 7·8 2·2  7·5|2·4  7·0  4·1|--   --   --  | 2·4  4·2  ·80
   4 | 7·8 1·6  8·6|2·4  5·4  3·2|--   --   --  | 1·5  2·3  ·70
     |             |             |              |
   5 | 6·4 4·4  7·7|2·4  5·2  3·0|--   --   --  |  ·9  1·8  ·80
   6 | 5·2 6·3  5·5|2·3  5·1  3·0|--   --   --  | 1·1  2·0  ·80

BRIGHT SUNLIGHT (South), 18--9--12.

20 Minutes.

     |    Vio. Red.|     Or. Red.|      Or. Yel.|          Red.
  1  |10·6 1·4  5·0|7·0  2·2  8·3|1·1  3·6   ·9 |10·0  --   7·0
     |             |             |          Red.|      Or.
  2  |10·0 --    ·8|7·0  2·6  7·4|--   1·0   ·3 | 7·4  2·0  3·6
     |     Or.     |             |              |
  3  | 9·2 1·6  2·2|4·5  5·5  8·0|1·8  7·4  --  | 5·2  4·2  8·1
     |     Or.     |             |              |
  4  |10·6  ·4  3·5|6·0  4·2  8·3| ·44 1·36  ·8 | 9·0  2·5  5·0
  5  |10·0  ·8  5·7|6·2  4·0  8·3|--    ·7   ·45| 7·0  5·0  4·0
     |             |             |              |
  6  | 6·2 4·6  7·7|5·0  7·5  4·0| ·2   ·4   ·5 | 5·4  7·1  4·5

BRIGHT SUNLIGHT (South), 18--9--12.

30 Minutes.

     |     Or. Red.|     Or. Red.|      Or. Red.|      Or. Red.
   1 |10·6  ·9  1·5|6·4  4·4  5·7|2·6  7·8  1·1 | 5·2  3·4 10·4
   2 | 9·2 1·4  2·9|6·2  5·3  5·5| ·1   ·7   ·4 | 7·8  3·0  5·2
   3 |10·8 1·2  1·5|7·2  3·4  8·4| ·7  2·0   ·2 | 9·2  1·6  5·2
   4 |10·0 2·0  1·5|6·2  4·4  6·9| ·5  1·0   ·7 | 8·2  2·0  7·3
     |             |             |              |
   5 | 9·6 4·4  4·5|5·8  5·0  7·2| ·2  1·9   ·7 | 6·2  3·8  6·5
   6 | 6·6 7·9  5·0|4·8  7·2  5·0| ·2   ·5   ·55| 5·0  7·5  2·0
  ---+-------------+-------------+--------------+---------------

BRIGHT SUNLIGHT (South), 18--9--12.

10 Minutes’ Exposure on White Sensitized Papers.

  ---+-------------+-------------+---------------
  NO.|GREEN SCREEN.| BLUE SCREEN.|VIOLET SCREEN.
  ---+-------------+-------------+---------------
     |Blk. Or. Red.|Blk. Or. Red.|Blk.  Or.  Yel.
   1 | ·26 ·69  ·10|5·2  4·4 8·4 |1·75  3·65  ·40
   2 |--   ·15  ·03|6·0  3·8 6·7 |1·7   3·9   ·40
   3 | ·22 ·02  ·04|5·6  5·9 6·5 |1·5   3·5  1·2
   4 | ·19 ·05  ·12|4·8  5·6 6·6 |1·3   3·2  --
     |             |             |           Red.
   5 |--   --   -- |4·0 10·5 2·0 | ·6   1·7  1·0
   6 |--   --   -- |4·0 11·5 1·0 | ·5   1·9  1·1

BRIGHT SUNLIGHT (South), 18--9--12.

20 Minutes.

    |     Or. Yel.|     Or. Red.|      Or.  Red.
  1 |3·1  6·1 1·8 |8·0  2·0 8·5 |4·5   7·5  4·5
    |             |     Or.     |
  2 |1·9  3·7  ·8 |8·8   ·6 3·6 |5·0   6·5  4·5
    |             |             |
  3 |1·0  7·0 1·6 |8·6  1·4 3·5 |4·0   8·5  4·5
    |             |             |
  4 |1·8  4·8 1·2 |8·0  2·2 6·8 |4·5   7·5  4·5
  5 |1·7  4·9 1·4 |7·6  2·4 8·0 |4·0   8·5  4·0
    |         Red.|             |
  6 |1·8  3·4  ·4 |6·4  4·4 8·2 |3·5   8·5  1·0

BRIGHT SUNLIGHT (South), 18--9--12.

30 Minutes.

     |    Or.  Yel.|     Or. Red.|      Or. Red.
   1 |1·0  6·8  ·2 |6·4  2·6 7·5 |4·2   6·8  6·0
   2 |1·8  3·4  ·2 |8·4   ·8 3·8 |5·4   8·1  1·0
   3 |2·2  5·2 2·2 |8·0  2·0 7·5 |4·5   8·5  4·0
   4 |2·5  4·7 2·0 |8·0  1·6 7·4 |3·7  10·3  1·0
     |             |             |          Yel.
   5 |1·6  4·2 2·8 |7·6  2·6 6·8 |3·1   9·4  1·5
   6 |1·5  3·9  ·2 |6·4  7·6 5·5 |3·4   9·7  1·5
  ---+-------------+-------------+---------------

It would be unsafe to draw definite conclusions from a few experiments,
but so far as permissible, the results show considerable differences,
both in depth and in colour, of the energy of the different rays, for
instance--

Compare Nos. 1 and 6 under 20 min. sunlight.

          Black.  Orange.   Red.

  No. 1   10·6  +  1·4   +  5·0
  No. 6    6·2  +  4·6   +  7·7

or again 3 and 6, the maximum and minimum, under 30 min. exposure.

         Black.  Orange.   Red.

  No. 3   10·8  +  1·2  +  1·5
  No. 6    6·6  +  7·9  +  5·0

The sensitiveness of Nos. 2, 4 and 5 appears to have been exhausted by
20 min. exposure to sunlight, further exposure showing no reaction;
whilst the sensitiveness of Nos. 1, 3 and 6 do not appear to have been
exhausted by 30 min. sunlight exposure.

Other noticeable points are the small action under the Orange, Green
and Violet screens, and the greater, although variable proportion of
colour to black under all the colour screens.


TRICHROMATIC COLOUR SCREENS.

Table VIII contains the colour measurements of five sets of screens for
trichromatic colour work which have come from time to time under the
writer’s notice.

The measurements are the tintometrical colour units required to match
the screens under daylight conditions, and are classified under the
theoretically accepted terms of Red, Green and Violet.


TABLE VIII.

  ----+-------------------------+-------------------------+--------------------
  Set.|       RED SCREENS.      |      GREEN SCREENS.     | VIOLET SCREENS.
  ----+-------------------------+-------------------------+--------------------
   No.| Red.  Or.   Vi.  Light. | Yel. Green. Or.  Light. | Blue. Green. Black.
    1 |119·0  ----  ----   1·6  | 27·0  36·0  ----   9·0  |  32·0   1·4   6·6
    2 | 24·2  +·8   ----  ----  |  8·9  ----    ·1  ----  |  13·0  ----   3·1
    3 | 26·4  ----   ·8   ----  |  7·5  ----   1·4  ----  |  16·6  ----   3·2
    4 | 22·6  ----  ----  ----  |  7·6  ----   1·4  ----  |  15·3  ----   3·1
    5 | 21·0  ----  9·0   ----  | 28·0  14·0  ----  ----  |  28·0  ----   2·8
  ----+-------------------------+---------------------------+--------------------

The Red screens are all practically pure except No. 5, which transmits
also 30 per cent. Violet. No. 1 is distinguished by its greater colour
depth and purity, the degree of which latter is recorded at 1·6 light
units brighter than standard.

In the Green division, only Nos. 1 and 5 transmit any green, No. 1
transmitting also 42·8 per cent. yellow and being 9·0 units brighter
than standards; No. 4 transmits 66·6 per cent. yellow to 33·3 per cent.
green; Nos. 2, 3 and 4 are all yellows tinged with orange.

In the Violet division, Nos. 2, 3, 4 and 5 are all pure blues; No. 1 is
tinged with green.




Appendix I

COLOUR EDUCATION


The time has passed when it might have been considered necessary to
preface a handbook on the teaching of colour by arguments to prove that
it is a legitimate subject of instruction in schools, but it has not
hitherto been sufficiently recognized that the early stages of such
instruction must be on sound lines and that nothing must be taught
which will afterwards have to be unlearned.

Apart from the pleasure its sensations give to all properly constituted
persons, the study of colour has an intellectual value in common with
other branches of science. It strengthens the judgment by constantly
requiring thought and precision in definition, it also develops the
faculty of colour perception even to the point of curing some forms of
colour blindness. In addition to this, it forms a necessary part of
the instruction in all schools in which drawing is properly taught by
methods which demand from the pupils faithful representations of the
appearances of actual objects in colour as they are seen.

In the past the systematic study of colour has been more or less
neglected from two principal causes: first, the want of a comprehensive
scheme of colour nomenclature capable of describing all colours in
terms precise enough for general understanding and record; and, second,
the absence of any reliable means of reproducing any specific colour
if lost or faded. Both these conditions may now be secured by the use
of the standardized coloured glasses supplied with the Colour Educator,
and this work is intended to bring the subject before teachers in such
a way as to make each point perfectly easy of demonstration to a class
in a systematic manner.

To-day the value and importance of a keen perception of colour and of
an apparatus furnishing definite colour standards, though perhaps not
much appreciated by the general public, are widely recognized in the
industrial and scientific world; and it is evident that in these days
of keen commercial competition between nations we cannot afford to
neglect any means which will enable us to maintain present industries
and to develop new ones.

=General Remarks.=--It is not advisable to introduce colour theories to
pupils before they know the names of the different colours, but, as the
glasses used in the apparatus are graded for colour-depth according to
a set of scales now generally accepted as of standard value, a short
description of the derivation of the colour names will be of service
when the pupils are sufficiently advanced.

The names of the six spectrum colours, Red, Orange, Yellow, Green,
Blue, and Violet, are accepted by common consent as describing the
principal hues into which a beam of white light can be resolved by
a diffraction grating or by prismatic refraction. They are also the
colours distinguishable in objects of everyday life, and the following
Educational Method is based on the fact that they can be separated at
will from ordinary daylight. Therefore the first educational step is to
associate these six colour rays with their respective names, the pupils
being made to understand that there are many degrees of depth in each
colour.

=The Applications of Colour to the Work of Everyday Life= are so
universal that a complete list is almost impossible, though some of
the most important are mentioned below. In a general way the visual
characteristics of every visible object are determined by contrasts of
light and colour, outline itself being governed by differences of light
intensity.

In Nature, colour is practically universal. There are few objects
perfectly white. Most of them have colour of greater or less
complexity; even snow under a cloudless sky has a blue tint which
is measurable against such white objects as pure lime sulphate,
zinc white, etc., the blue tint being manifestly reflected from the
cloudless sky, as it disappears under a cloudy overcast.

=Some of the Scientific Applications of Colour.=--It associates colour
sensations with definite names and values; discovers and classifies
cases of colour-blindness, and is a preparation for the physical
study of light. It is also essential for studying the physiological
structure of the organs of vision, for disclosing abnormal conditions
of the blood, and for measuring the colour of the hair and skin for
the anthropological classification of races. It is used in general
laboratory work for analytical and original investigation; and
it furnishes standards of value for the petroleum industry, the
International Tanning Association, the inter-States Cotton Seed Oil
Association, etc. It is also one of the principal factors in all
artistic industries; for, besides having an important educational
value in questions of harmony, contrast, and taste, it is of direct
commercial value in such industries as dyeing, calico printing,
all woollen industries, wall-paper printing, paint making, house
decoration, etc.

=General Instructions for Using the Apparatus.=--The apparatus consists
of a frame having six little windows, fitted with sliding shutters, and
a tray containing eighteen standardized glasses.

The frame must be placed on a table or stand facing the children, with
a window or some other source of diffused white light behind it. Care
must be taken not to have a coloured background of any kind.

The glasses are in three colours, Red, Yellow, and Blue, of different
depths. The depth of colour is marked in figures on each glass, and
corresponding numbers in the three colours are of equal intensity. It
is of importance that the six spectrum colour terms should be the only
ones used in the preliminary stages. The first step in colour teaching
must be to develop and train the perceptive faculties of the children
so as to enable them to express in words the colour sensations which
are excited. For this purpose it is necessary to begin by demonstrating
that the six spectrum colours Red, Orange, Yellow, Green, Blue, and
Violet, are derived from white light.

Red, Yellow, and Blue should first be dealt with, and _for practical
work_ each pupil should be supplied with three water-colour pigments
closely corresponding in hue to the standardized glasses, viz., Crimson
Lake, Lemon Yellow, and Cobalt Blue; also with a piece of white paper
ruled into six small rectangular spaces corresponding to the little
windows of the apparatus.

As each colour is demonstrated by means of the glass in the apparatus,
each pupil should paint the corresponding pigment in its proper place
on the paper.

The little shutters being placed in all the six little windows, remove
the top left-hand shutter and insert a deep _Red_ glass, thus showing

=Red.=--The pupils will name this and then paint the corresponding
colour on their papers.

Next, remove the shutter below the first one, and insert a _Yellow_
glass of the same numerical value as the Red one, thus showing

=Yellow.=--The pupils will name this and then paint the corresponding
colour on their papers.

Now remove the shutter next below and insert a _Blue_ glass of the same
numerical value as the Red and Yellow ones, thus showing

=Blue.=--The pupils will name this and then paint the corresponding
colour on their papers.

            +--------+--------+
            | 1      |        |
            |        |        |
            |  RED   |        |
            |        |        |
            +--------+--------+
            | 2      |        |
            |        |        |
            | YELLOW |        |
            |        |        |
            +--------+--------+
            |3       |        |
            |        |        |
            | BLUE   |        |
            |        |        |
            +--------+--------+

There are now exposed to view the three colours which are by artists
commonly called primaries, but it will be found convenient to term Red,
Yellow, and Blue the _Dominant_ colours of this system.

The second step is to show how the three secondary or subordinate
colours are derived or developed.

Remove the top right-hand shutter and insert a deep Red and a deep
Yellow glass of equal depth, showing the pupils that these two colours
combined in equal proportions develop

=Orange.=--The pupils will name this, and will then mix their Red and
Yellow pigments to obtain a similar Orange which will be painted in its
proper place on their papers.

Now remove the shutter next below and insert a deep Yellow and a deep
Blue glass of equal depth, showing the pupils that these two colours
combined in equal proportions develop

=Green.=--The pupils will name this, and will then mix their Blue and
Yellow pigments to obtain a similar Green which will be painted in its
proper place on their papers.

            +----------+----------+
            | 1        | 4        |
            |          |          |
            |   RED    |   ORANGE |
            |          |          |
            +----------+----------+
            | 2        | 5        |
            |          |          |
            |  YELLOW  |  GREEN   |
            |          |          |
            +----------+----------+
            |3         | 6        |
            |          |          |
            |  BLUE    |  VIOLET  |
            |          |          |
            +----------+----------+

Remove the last right-hand shutter and insert a deep Red and a deep
Blue glass of equal depth, showing that these two colours combined in
equal proportions develop

=Violet.=--The pupils will name this, and mix their Blue and Red
pigments to obtain a similar Violet, which will also be painted in its
proper place on their papers.

Now are exposed to view on the left-hand side the three primary or
dominant colours, and on the right-hand side the three secondary
or subordinate colours, and the whole frame is filled with the six
spectrum colours in equal colour depth. Corresponding to the colours
in the frame, each pupil’s paper should show a similar arrangement of
colours, and the pupils can be taught their spectrum order by reading
them in rows horizontally--Red, Orange, Yellow, Green, Blue, and Violet.

The teacher should now take out the coloured glasses and replace the
shutters, except the two top windows, one of which is left open to
show white light, and the other filled with three equally deep glasses
in Red, Yellow, and Blue, showing either black or neutral grey, and
demonstrating the total or partial absorption of light according
to their higher or lower numerical unit value. It is of the utmost
importance to bear in mind that the glasses are graded for diffused
daylight, and that all artificial lights are more or less coloured and
would give a different effect. The same remark applies to light taken
direct from coloured objects.

In this set the six windows are in one horizontal line, and should be
uncovered in the following order:

                 { No. 1 Window for Red.
    Dominants    {  "  3   "        Yellow.
                 {  "  5   "        Blue.
                 {  "  2   "        Orange.
    Subordinates {  "  4   "        Green.
                 {  "  6   "        Violet.

One advantage in this method is that when all the colours are in they
are arranged in their spectrum order.

=Complex Colours.=--We have demonstrated that single standard glasses
develop the three Dominant colours, Red, Yellow, and Blue, and that
pairs of equal standard glasses develop the three Subordinate colours,
Orange, Green, and Violet. In order to produce complex colours
two standard glasses of unequal value must be used. The degree of
inequality does not alter the spectroscopic names of complex colours,
variation in proportions being only a statement of degree.

              Complex Name.        High value.  Lower.

    To develop a Red-Orange insert a Red and Yellow.
          "      Yellow-Orange   "   Yellow and Red.
          "      Yellow-Green    "   Yellow and Blue.
          "      Blue-Green      "   Blue and Yellow.
          "      Blue-Violet     "   Blue and Red.
          "      Red-Violet      "   Red and Blue.

A reference to the circles, 7, 8, and 9, on the cards supplied with
the apparatus will show that all complex colours are members of the
same triad group, and experiments have shown that the six combinations
above are the only ones distinguishable in Nature, subject, however, to
unlimited variations in brightness or dullness. It remains to be shown
how these variations are effected.

Variations in brightness are produced by inserting with the two glasses
forming a complex colour the third spectrum colour, always bearing
in mind that it must be less in value than either of the other two.
The addition of the third colour has a dulling or saddening effect,
the degree of which is determined by the numerical value of the third
colour. The colour produced by the addition of the third colour may
be termed a saddened or dingy colour, the appearance being that of a
brighter colour seen in shadow.

Reviewing the foregoing, it is demonstrated that primary or dominant
colours are transmitted by a single coloured standard glass; the
secondary or subordinate colours are transmitted by two equal standard
glasses of different colours; the complex colours by two unequal
standard glasses of different colours. Saddened pure colours are
developed either by one coloured standard glass combined with two equal
standard glasses of different colours and lesser value or by two equal
standard glasses of different colours and a third of lesser value.
Saddened complex colours by three unequal standard glasses of different
colours. Greys, which are steps towards blackness, are produced by
three equal standard glasses of different colours.

It is well known that Colour Blindness is a defect in the vision often
involving the confusion of such utterly distinct colour sensations as
Red and Green, Orange and Violet, and many others as widely different.
In the cases of Red and Green the confusions are specially disastrous
should the subject be a railwayman or a sailor. It is not, however, so
well known that many cases of so-called Colour Blindness are in reality
cases of Colour Ignorance, and the capacity for distinguishing between
colours and shades is often latent, and only waiting to be developed by
Education.

When a child persistently misnames colours after having received an
amount of instruction sufficient to remove colour ignorance in a normal
case, the errors are probably due to some form of colour blindness.

Such cases should be registered for further examination, taking note of
the miscalled colours. It would be an additional precaution to change
the position of the colours in the windows of the apparatus, in order
to prevent the association of colours with their positions as first
given in the instructions.

_Note._--The paints which most nearly correspond to the colour
standards in the Colour Educator are tabulated below, the third column
containing their measured colour proportions when they are washed
thickly on white paper (_Whatman’s_).

  --------------+---------------+-----------------------------------------------
                |               |     Colour Composition in Standard Units.
   Spectrum     | Artists’      +-------+-------+-------+-------+-------+-------
     Names      | Names.        |       |       |       |       |       |
                |               | Red.  |Orange.|Yellow.| Green.| Blue. |Violet.
  --------------+---------------+-------+-------+-------+-------+-------+-------
                |               |       |       |       |       |       |
   Dominants:   |               |       |       |       |       |       |
     Red        | Crimson Lake  |  18·0 |   0·4 |  ---- |  ---- |  ---- | ----
     Yellow     | Lemon Yellow  |  ---- |  ---- |   6·6 |  ---- |  ---- | ----
     Blue       | Cobalt        |  ---- |  ---- |  ---- |  ---- |   9·0 | ----
                |               |       |       |       |       |       |
   Subordinates:|               |       |       |       |       |       |
     Orange     | Chrome Orange |  ---- |   7·2 |   1·6 |  ---- |  ---- | ----
     Green      | Emerald Green |  ---- |  ---- |   0·40|   5·4 |  ---- | ----
     Violet     | Mauve         |   3·3 |  ---- |  ---- |  ---- |  ---- |  8·2
  --------------|---------------+-------+-------+-------+-------+-------+-------

In mixing two dominant colours (artists’ primaries) to develop
subordinates (artists’ secondaries), their relative colour depth must
be taken into account; for instance, Crimson Lake has a natural colour
depth nearly three times that of Lemon Yellow; therefore, in order to
develop a normal Orange nearly three times the quantity of Yellow must
be used, presuming that they were originally ground to an equal degree
of fineness.

It is desirable that a record of the children’s own painting should be
preserved, with a view to discriminating between errors arising from
Colour Blindness and Colour Ignorance, the former perpetuating itself,
and the latter naturally remedying itself. For this purpose painting
books containing sets of diagrams corresponding to the figures in the
foregoing pamphlet can be supplied.




Appendix II

THE POSSIBILITIES OF A STANDARD LIGHT AND COLOUR UNIT.[5]

[5] Reprinted from the _Journal of the Society of Dyers and
Colourists_, March, 1913. No. 3, vol. xxix.

The past attempts to standardize light and colour are mainly limited
to those radiant energies which excite light and colour sensations
under diffused daylight conditions, because in direct sunlight, and in
most artificial lights, there are other colour energies, which, unless
sufficiently modified by diffusion, disturb the colour readings. There
are also latent colour energies, which only become distinguishable
by special means. They do not, however, appear to influence diffused
daylight colour work.

The definition of a normal vision is one which agrees with a majority
of others. This definition has proved satisfactory up to the present,
as the normals are many and the colour blind few.

_Light Intensities._--There are two methods of determining light
intensities by means of a graded scale of light absorbents.

First. By total absorption of the light, when the intensity is directly
represented by the unit value of the absorbents required. This method
is applicable for low lights, internal surfaces, such as a desk, etc.,
where a standard light is not available for comparison.

Second. By the reduction of a standard light by absorption until it
equals the light of the object. In this case the standard must be
originally brighter than the object.

_Constants._--The first requirement in establishing a scale of light
and colour units is a means of co-relating visual sensations to a scale
of physical colour constants, in order to secure a power of record and
recovery. There is no natural scale available for quantitative colour
work, but artificial scales can be constructed, and made constants by
co-relation at different points with physical colour constants, and by
cross-checking the intervals between these.

The scales used in the “tintometer” consist of red, yellow and blue
glass, so graded in equivalents that combinations of equal units
transmit colourless light. Full details of these have already been
placed before the Society (see this _Jour._, 1887, p. 186, and 1908, p.
36).

=Scale of Luminous Intensities.= _The Light Unit._--The natural
terminals in a scale of luminous intensities are black and white, and
the first question which arises is what is black, and what is white?
as when used in a popular sense each term covers a wide range of
differences.

In the author’s sense the term black means total absence of light,
and the term white means a diffused daylight of given intensity, as
reflected from a lime sulphate surface. In this sense black and white
are the terminals of a scale of light intensities; the scale is divided
into units and fractions of units. The unit itself is physiological,
and is not in progressive accord with the mathematical light unit based
on the inverse squares of distance.

_The Black Unit._--Ideal black is practically obtained under daylight
conditions by viewing a hole in a box with blackened interior, so
arranged that no entering light can be reflected back to the vision.

The box used for this purpose is illustrated in Fig. 3, and has one
surface covered with standard white for the purpose of easy comparison
with the pigments. The standard black aperture (1) is in the middle.
The pigmentary blacks (2 to 10) are arranged over this, and the
pigmentary whites and greys (11 to 20) underneath, each being numbered
in accord with its intensity as tabulated.

[Illustration: Fig. 3.]

The degrees of blackness are the number of absorptive units required to
reduce the standard white to equal the pigments in each case.


Light Absorbed by Various Pigments.

  ---+---------------------+--------+----------+-------
  No.|                     |Absorbed|Unabsorbed|Initial
     |                     | Light. |  Light.  | Light.
  ---+---------------------+--------+----------+-------
   1 |Black Hole in Box    |   36   |   --     |  36
   2 |Optical Black        |   20   |   16     |  36
   3 |Lamp Black           |   17   |   19     |  36
   4 |Vegetable Black A    |   17   |   19     |  36
   5 |    "       "   B    |   14   |   22     |  36
   6 |    "       "   C    |   15   |   21     |  36
   7 |Indian Ink on Paper  |   14   |   22     |  36
   8 |     "    Solid      |   12   |   24     |  36
   9 |Boot Black           |   11   |   25     |  36
  10 |Black Lead           |    9   |   27     |  36
  ---+---------------------+--------+----------+-------

This gives a working scale of colourless light intensities, the
terminals being black and white, with a range of 36 units.

_The Standard White._--White is the natural terminal of the luminous
end of the scale, and it is necessary to select a physical objective
white as a constant. Pure precipitated lime sulphate has been adopted,
and departures from the light intensity of this are recorded in units
of lessened light intensity throughout the scale, comprising all
degrees of colourless whites, greys, and blacks.

Strictly speaking, white is a qualitative term only, until the degree
of variation from the zero of the scale has been established. The
measured variation then takes its position in the scale of luminous
intensities according to its numerical unit value.


Light Absorbed by Various White and Grey Pigments.

  ---+--------------+--------+---------+-------
  No.|  Pigments.   |Absorbed|Reflected|Initial
     |              | Light. |  Light. | Light.
  ---+--------------|--------+---------+-------
   11| Grey Paint E |  6·0   |   30·0  |   36
   12|     "      D |  5·0   |   31·0  |   36
   13|     "      C |  4·0   |   32·0  |   36
   14|     "      B |  2·0   |   34·0  |   36
   15| White Paint A|  0·7   |   35·3  |   36
   16| White Paper D|  0·3   |   35·7  |   36
   17|      "      C|  0·2   |   35·8  |   36
   18|      "      B|  0·25  |   35·75 |   36
   19|      "      A|  0·15  |   35·85 |   36
   20| Chinese White|  0·006 |   35·994|   36
  ---+--------------+--------+---------+-------

As the scale is differentiated into hundredths of a unit, there can be
100 variations of white pigments in a single unit, each quite easily
distinguishable from the others.

Any definite mixture of black and white finds a position on the
diagonal of a chart whose co-ordinates are the black and white scales;
for example, the 20 measured pigments are charted on Figs. 4 and 5, the
latter being on an enlarged scale, as the whites would be too crowded
to be noted on Fig. 4.

[Illustration: Fig. 4.]

The merging of white into grey, and of grey into black is gradual,
having no strict lines of demarcation.

An example of this method of determining light intensities is
illustrated in Fig. 6 by the light intensities at which different
objects are discernible. The points of most interest are, that colour
is indistinguishable as such in lights below 15 units intensity; and
that ordinary work, such as reading a newspaper, requires for comfort a
minimum of 28 units.

_The Colour Unit._--The colour unit is physiological, and its
dimensions are determined by the dimensions of the colourless light
from which it is derived. This deduction is based on the experimental
fact that colourless light is a mixture of the six colour rays--red,
orange, yellow, green, blue, and violet--in equal proportion, as
illustrated in Fig. 7, showing that a white light of 20 units light
intensity is made up to the six colour rays, each of 20 units colour
intensity. This is demonstrated by the fact that any proportion of
any colour can be developed at will by means of the glass standard
scales already mentioned; it follows that the smallest disturbance of
equivalence between the composing rays results in the development of
colour.

[Illustration: Fig. 5.]

The above remarks apply to both simple and complex colours, and
the complex colours are always dichromes, being governed by
another physiological fact, which is: That the vision is unable to
simultaneously distinguish more than two colours in the same beam of
light. The order of their association is definite, and may be described
by saying that the combined two are always adjacent in their spectrum
order, red and violet being considered adjacent for this purpose. It
follows that all complex colours are binaries, and the only possible
combinations are as follows:--

            Red    with Orange.
            Orange   "  Yellow.
            Yellow   "  Green.
            Green    "  Blue.
            Blue     "  Violet.
            Violet   "  Red.

[Illustration: Fig. 6.]

In the author’s colour nomenclature, a monochrome is qualitatively
described by a single term, and a complex colour by a combination of
two single terms. For a quantitative description, it is only necessary
to add the measured unit value to each term. When there is excess of
brightness, or a saddening factor, these also must be quantitatively
estimated.

The colours developed by means of these scales are governed by the same
law of selective absorption which governs the development of natural
colours, any of which can be matched and reproduced by means of their
established ray proportions.

[Illustration: Fig. 7.]

The governing law is simple, and may be stated by saying that the
colour developed is always complementary to the colour absorbed, not in
the generally accepted sense that their mixture necessarily makes white
light, but in the sense that they are opposite in the cycle of daylight
colours.

The dimensions of the unit are necessarily arbitrary, it was originally
selected as being a convenient depth for distinguishing differences,
the scale was then constructed by equal additions and sub-divisions;
the two essentials of a scientific scale being complied with, in
that the divisions were equal and the unit recoverable. The power
of recovery lies in the fact that different parts of the scale are
co-related to physical colour constants, which can be prepared in any
laboratory.

[Illustration: PLATE VIII ABSORPTION CURVES OF SIX DYES.
  _To face page 76._]      [_Lovibond, Colour Theories._
]

_Specific Colour._--The relationship of colour increase to intensity
increase in substances has hitherto been somewhat obscure. It has been
sometimes considered that they were in direct proportion, but in the
absence of a means of recording colour sensations, no definite results
were obtainable.

[Illustration: Fig. 8.]

Sufficient information is now available to warrant the formulation of
the following law: “That every substance has its own rate of colour
development for regularly increasing intensities, which, when once
established, becomes a constant for identifying similar substances
in future.” This is the meaning of specific colour, and when a
series of measurements at regularly increasing densities of a given
substance have been made, the specific colour rate of that substance
is established. This can be charted in curves and used as a basis for
estimating quantities, properties, changes of condition, differences in
value, detecting adulteration, etc.

_Applications._--The author has permission to use the names of several
gentlemen who have used the tintometrical scales for various purposes.

Sir Arthur H. Church, F.R.S., has employed the tintometrical standards
for the purpose of registering the colours of certain wild flowers.

Sir Boverton Redwood has used the scales and system for petroleum
investigations. At his instance the specific colour rate of petroleum
was established, and the several composing colours plotted in
curves, as in Fig. 8, where the ordinates represent the scale of
units irrespective of colour, and the abscissæ the scale of strata
thicknesses.

The measurements were made at two-inch intervals, and the four
perpendicular lines are at the colour points selected for valuing
the four distinguishing marks, technically known as “Water White,”
“Superfine,” “Prime,” and “Standard.” Intermediate qualities find their
position in the scale of curves according to their measured colour
values.

This method of standardizing commercial values has also been adopted by
the International Tanners’ Association, the Inter-States Cotton Seed
Oil Association, and other oil industries. Also for scale, solid fats,
and such substances as can be easily melted and measured by transmitted
light.

=Varying Effects of Different Lights.= _Pathological
Applications._--The law of specific colour development was made use of
by Dr. George Oliver in determining the degrees of hæmoglobin in the
blood. The method is fully explained in his Croonian Lecture before the
Royal College of Physicians of London, July 11, 1896.

_Detection of Forgeries._--The system and apparatus is used by
Professor A. S. Osborne, Examiner of Questioned Documents, New York
City, for determining the variety of ink, the age of the writing,
and the detection of forgeries. A full description of the process will
be found in his work entitled _Questioned Documents_, published by the
Lawyers’ Co-operative Society, Rochester, N.Y.

[Illustration: PLATE IX SIX ANILINE DYES.
CURVES ILLUSTRATING THE RATE OF FADING BY EXPOSURE TO LIGHT.
  _To face page 78._]       [_Lovibond, Colour Theories._
]

The application to chemical analysis is too well known to require
enlargement here.

[Illustration: Fig. 9.]

_Dyes._--As an example of the use of the system in the valuation of
dyes, Fig. 9 illustrates the specific colour curves of four samples
of Methylene Blue. No. 1 was priced at 5_s._ 9_d._ and No. 2 at 5_s._
per lb., Nos. 3 and 4 were not priced, the solutions were measured in
percentages from 0·001 to 0·048 in distilled water. To find the cost
per unit of colour in the priced samples is only a question of simple
arithmetic, which furnishes data for the valuation of the unpriced
samples.

The yield in the dye vat may not be in direct relation to the solutions
in water, the establishment of this is a question for the expert, and
presents no apparent difficulty.

The use of the scheme in recording the degree of fading of dyes has
been previously dealt with in the _Journal_ (_q.v._, 1908, p. 36).

_Limitations and Precautions._--It has been shown that we have
analytical control, within certain limits, of light and colour under
daylight conditions.

The general limits for colourless light range from total darkness to 28
units, when the unabsorbable red ray comes into evidence.

For colour, the general limits range from 28 to 18 units, between 18
and 15 all colours become indistinct, but at varying rates, below 15,
colour is not distinguishable.

The principal disturbing conditions in making observations are _want
of colour education_ and _insufficient diffusion_. In the case of the
latter, the first evidence is the disturbance of constancy by the
penetrating red ray. A partial remedy is to interpose a white diffusion
screen, such as tissue paper.

_Time of Observation._--This should not exceed five consecutive
seconds, as the keenness of perception decreases by time, but varies
for different colours.

_Angle of Incidence._--Sixty degrees is safe for most solids, but for
bright or polished surfaces, such as varnishes, polished metals, etc.,
the angle must be lessened as the degree of smoothness increases. For
very rough surfaces, such as loosely woven stuffs, etc., care must be
taken that the lay of the fibre is uniform.

_Distance from the Object._--Ten inches has been adopted for general
work, but certain visions require more or less as their focus varies
from normal.

[Illustration: PLATE X COMPARISON CURVES OF HEALTHY AND DISEASED BLOOD.
  _To face page 80._]  [_Lovibond, Colour Theories._
]

_Unabsorbable Colours._--In addition to the daylight colours already
dealt with, there are, in direct lights, colours which do not obey the
laws of absorption governing those of diffused daylight.

The work already done on these unabsorbable rays has only been
incidental, where they happened to interfere with the standardization
of diffused daylight colours. The sensations excited are red and
violet. They blend, producing red-violet mixtures, but in unequal
proportions, the red being dominant.

The red is developed in intense lights by constant interception of
neutral tint absorbents. In the case of a 4-volt incandescent light,
the first absorption simply reduces the light intensity without
developing colour; the light is colourless up to 14 units. At 16
units the light begins to assume a reddish hue, which rapidly becomes
a brilliant intense red by further interceptions of neutral tint
absorbents.

Violet is developed by constant absorption by blue standards, which
grows in intensity by successive additions up to about 120 units.
Beyond this point the brilliancy decreases.

Preliminary experiments point to this ray as fatal to vegetation, and
presumably also to lower forms of organic life.

There remains a factor of considerable importance which has not yet
received the attention it deserves, the physiological changes resulting
from environment.

This aspect of the question has come under the notice of the author
by measuring the vision of experts who excelled in given hues. It was
generally found that their vision was sensitive to a small increment of
their particular colour in harmonies where it was silent to a normal
vision.

In seeking an explanation of this phenomenon there are at least three
possible lines for working:

First. Is the vision naturally more sensitive to that particular energy?

Second. Is it by careful education?

Third. Is it an unconscious adaptation to surroundings, such as other
organs undergo under changes of environment?

[Illustration: PLATE XI SPECIFIC COLOUR CURVES OF HEALTHY AND DISEASED
HUMAN BLOOD
  _To face page 82._]      [_Lovibond, Colour Theories._
]




Appendix III

    THE APPLICATION OF THE NATURAL LAW OF SPECIFIC COLOUR RATE BY
    DR. DUDLEY CORBETT TO THE EXACT MEASUREMENT OF X-RAY DOSAGE.


Dr. Dudley Corbett.

The gradations in the tint given by the Sabouraud-Noiré pastille
when exposed to X-rays are so fine, especially in that region of the
colour scale where lies the erythema dose, that many have felt the
want of a more accurate means of reading these tints, as well as a
series of reliable standards for comparison. Hitherto the only methods
at all generally used have been Hampson’s radiometer and Bordier’s
radio-chronometer, the former in this country, and the latter on the
Continent. Hampson’s instrument has two disadvantages: it can only be
used with electric light, and the standards are made of tinted paper
liable to get soiled, and to vary slightly with the changes in the
pigment employed. Its advantage is that it may be used as a sliding
scale, thus economising the pastilles. Some persons, however, have
considerable difficulty in reading the tints, the scale rising only by
gradations of 1/4 B.

In the construction of any such instrument, the really important
point is to obtain a reliable standard for Tint B--_i.e._, the normal
epilation dose. The tints on the Sabouraud card itself are not always
identical, some representing a dose which will only just epilate,
others an almost dangerous dose for unfiltered rays. The Tint B, which
is the standard, allows a margin of error of 20 per cent. on either
side. In other words, 4/5 B will almost always epilate, while 1-1/5
B is nearly the limit of safety. This observation is in accordance
with the experience of other workers on this subject. In my instrument
Tint B has been obtained by measuring the pastille with Lovibond’s
tintometer immediately after exposure to the X-rays. The pastille was
turned to a tint corresponding to an epilation dose which was known to
be safe, as proved by clinical results. This tint was measured directly
both by daylight and by artificial light from an 8-candle power carbon
filament lamp with frosted glass shade. I am indebted to Mr. Dean for
suggesting the use of Lovibond’s instrument for this purpose.

The methods employed in the experimental work have been described in
the _British Journal of Dermatology_ for August, 1913. By using a
very constant focus tube and averaging a large number of readings and
correlating the results with those obtained in clinical practice, we
were able to construct the curves indicating the colour developed by
the pastille. In these curves, shown in Fig. 10, the ordinates are the
Lovibond colour units, the abscissa the time during which the current
was actually passing. When using an interrupter working at a constant
speed, the actual time was taken, otherwise the number of current
interruptions as measured by a dipper tachymeter was used.

As was to be expected, the daylight and electric light curves were
quite different. In each case the standard yellow glasses employed were
kept constant throughout the curve, that for daylight being 15 units,
that for electric light 13 units. When these were combined with blue
and red glasses in varying units and fractions of a unit, they gave
a colour range which matched the pastille exactly in the changes it
undergoes from the unexposed condition to the 2 B Tint.

The curves are plotted in accordance with Mr. Lovibond’s practice--that
is, not as a direct representation of the standard glasses used, but as
showing the colour sensation received by the eye.

[Illustration: Fig. 10.]

First, as to the daylight curve: In order to match the unexposed
pastille we interpose between the pastille and the observer’s eye
a yellow and a blue glass, plus a certain amount of neutral tint
(composed of three equal colour units). Thus the colour sensation
received is a yellow green, together with a certain amount of white
light. As the pastille darkens under irradiation, both the green and
the white light disappear, until at a point just below the 1/2 B dose,
there is no other colour present but yellow. After this red glasses
are required--_i.e._, the colour sensation is a yellow orange, which
gradually deepens owing to an increase in the proportion of red. The
yellow curve thus rises till just below the 1/2 B point, and then falls
as the orange increases.

Next, as to the electric light curve. The unexposed pastille has but
a trace of green, which is soon lost. The orange begins much earlier
than in daylight, and thus at Tint B has reached a higher point than in
daylight. From this point the orange and yellow parts of both curves
run practically parallel with one another up to 2 B. Beyond 2 B the
readings become more difficult. I have not determined the point when
no more colour develops, as it has no great practical value, though it
might well be of interest from a physico-chemical standpoint.

In my radiometer the standards are composed of the Lovibond standard
glasses in combination. The apparatus itself consists of an optical
instrument or viewing box. This is divided by a central partition,
so that on looking through the eyepiece one sees a white background
through two small circular apertures. On one side, level with the
background, is a fitting to take the pastille in its holder. On the
other side is a groove in the instrument itself for the insertion of
the standard glasses. A similar groove is fitted on the pastille side
of the instrument to take neutral tints if required. The colour of the
pastille as seen by reflected light can thus be compared with that
obtained by transmitted light through the standard glasses seen against
the white background. A difference of 1/5 B or 1 H is quite easily
perceivable.

It is usually of no great importance to obtain extremely accurate
measurement of the smaller fractions below 1/3 B. Where this is
necessary, neutral tints must be used when working with daylight. With
electric light these are unnecessary. When required the neutral tints
are interposed between the pastille and the eye to absorb the white
light reflected from the pastille. The neutral glasses required are 1·5
for the unexposed pastille, 0·6 for 1/4 B, and 0·2 for 1/3 B. These
values are subject to slight variations due to changes in the varnish
of the pastille emulsion. The difficulty can always be avoided by using
electric light, where a trace of neutral tint is needed only when
matching the unexposed pastille--an unimportant point.

_Method of Use._--The choice of daylight or artificial light is a
personal matter, but one should practise reading the scale with both.
The use of the instrument shows that the pastille fades very nearly as
quickly under electric light as it does under daylight. The following
precautions should be observed: In daylight work in a good white
light, avoid shadows and yellow light of any kind. With electric light
use an 8-candle power carbon-filament lamp with frosted glass and a
suitable white shade so arranged that the pastille is 8 inches from the
lamp. No other light should be allowed to reach the pastille during
examination. A low power metal-filament lamp may be used, but greater
accuracy will be obtained with a carbon-filament lamp which was used
for the experimental work. The lamp should be discarded as soon as
the light becomes yellow from prolonged use. Whether in daylight or
electric light, the examination must be rapid to avoid the fading of
the pastille. When it is desired to give an accurate 1 B dose, it is
better to put up the 4/5 B standard first. It is then easy to calculate
how much more exposure is required for the extra 1/5 B. It is important
to adjust the pastille carefully so that none of the unirradiated green
portion is visible through the small aperture, as this will upset the
reading. In very accurate dosage new pastilles should be used, as a
bleached pastille never returns exactly to its original tint. When such
a bleached pastille is irradiated the colour changes start a little
farther down the curve, and thus the tint for a given dose must be
taken a little above the normal tint. This increase is very slight,
but is nevertheless quite appreciable, and may amount to as much as
5 and 10 per cent. Even then the margin for error is ample in the
neighbourhood of the B tint, and if a pastille is not used more than
three times, and is well bleached in daylight after each exposure, no
serious error is likely to occur. A standard white background should
always be used, and discarded for a new one when it gets dirty. The
colour standards usually provided are those in common use--namely,
1/4, 1/3, 1/2, 4/5, 1, 1', and 2 B, but it is quite easy to make up
standards for any point on the curve. The symbol “B,” as the erythema
or epilation dose, has been retained, as it was thought inadvisable to
add to the number of such symbols already existing.

To sum up:

1. The experimental work has determined the exact colour changes
occurring in the Sabouraud pastille when exposed to X-rays.

2. These experiments have established a permanent standard for Tint
B, which matches the pastille exactly, does not fade, is easily kept
clean. These coloured glasses can be readily and accurately reproduced,
as they are standardized spectroscopically by a firm who specialise in
such work. The standard will therefore remain constant so long as the
Sabouraud emulsion remains unaltered.

3. Glasses may be prepared of the correct tint for any fraction or
multiple of this dose up to 2 B or 10 H.

4. Either daylight or electric light can be used.

5. The optical instrument itself, by cutting off extraneous light,
greatly assists the colour comparisons, so that the practical error
need never exceed 10 per cent.




INDEX


  Abnormal light, 13

  Analysis of white light, 11, 13

  Arbitrary scales, 9

  Artists and scientists, 1, 2


  Beam of white light, 7, 11

  Black units, 16, 23

  Black, ideal, 15, 11

  Blood curves, 33


  Code of laws, 7

  Colour charts, 31, 39
    education, 59
    equivalence, 10
    nomenclature, 17, 21
    qualitative, 17, 19, 24
    quantitative, 24
    scales, 20, 29
    standardization, 20, 69
    theories, 2, 3

  Coloured surfaces, 44

  Colours, complex, 18
    sadder than standards, 25
    simple, 17

  Corbett, Dr. Dudley’s, radiometer, 83


  Daylight colours, 24, 84
    measurement, 14

  Diffused light, 10, 43

  Direct lights, 46

  Dulled colour, 10, 18-26, 36


  Equivalent colour units, 7, 9, 29


  Fog, whiteness of, 10


  Glass standards, 20


  Human blood curves, 82


  Laws of colour, 7

  Light, 11, 13, 42, 45-46, 81-84
    abnormal, 8
    brighter than standards, 14, 27
    direct, 46
    for colour work, 42
    intensities, 42, 43
    white, 14

  Lovibond’s new colour theory, 5


  Matching colours brighter than standards, 18
    complex colours, 17

  Measuring and naming colours, 21

  Monochromes, 17, 19

  Munro, Dr., 34


  Neutral tint, 18, 24, 26

  North light, 15


  Past theories, 3

  Photographic energies, 53

  Physical colour constants, 8

  Pigmentary black, 15, 71

  Primary colours, 1

  Prismatic spectrum colours, 29


  Qualitative analysis of colour, 17, 19, 24

  Quantitative analysis of colour, 24


  Radiometer, 83

  Rate of colour absorption, 8

  Rays, six colour, 7

  Red ray, 41


  Scales, arbitrary colour, 9
    coloured, 10, 20
    cross checking of, 9

  Scientists and artists, 1, 2

  Sea fog, 10

  Specific colour, 32

  Spectrum colours, 4, 18, 36


  Three colours, 10, 57

  Time, appreciation of colour by, 42


  Ultra violet, 32, 40

  Unit, checking of, 9

  Unit, neutral tint, 18, 24, 26


  Wave length position, 37, 38

  White light, 11, 13


Butler & Tanner Frome and London




Transcriber’s notes:


In the text version, italics are represented by _underscores_, and bold
and black letter text by =equals= symbols. Superscripts are represented
by ^{} and subscripts by _{}

Missing or incorrect punctuation has been repaired. Inconsistent
spelling and hyphenation have been left,

In the html version, dittos have been replaced by the repeated text so
that text aligns for easier reading.

Very wide tables (V and VI and VII)have been split to fit on portrait
oriented pages.

The following mistakes have been noted:

  p. 21. NiSO_{4}7H_{2}O, tem." is formatted inconsistently. Left as
    printed.
  p. 40. Fraunhoper is almost certainly a typo for Fraunhofer.
    Left as printed.
  p. 46. interpretated changed to interpreted.
  p. 55. In Paper 6 of table, Red screen, yellow entry, from alignment and
    logic, the 6 should be .6. Left as printed
  p. 61 conditonschanged to conditions.





End of Project Gutenberg's Light and Colour Theories, by Joseph W. Lovibond

*** END OF THE PROJECT GUTENBERG EBOOK 57335 ***