1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
6170
6171
6172
6173
6174
6175
6176
6177
6178
6179
6180
6181
6182
6183
6184
6185
6186
6187
6188
6189
6190
6191
6192
6193
6194
6195
6196
6197
6198
6199
6200
6201
6202
6203
6204
6205
6206
6207
6208
6209
6210
6211
6212
6213
6214
6215
6216
6217
6218
6219
6220
6221
6222
6223
6224
6225
6226
6227
6228
6229
6230
6231
6232
6233
6234
6235
6236
6237
6238
6239
6240
6241
6242
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305
6306
6307
6308
6309
6310
6311
6312
6313
6314
6315
6316
6317
6318
6319
6320
6321
6322
6323
6324
6325
6326
6327
6328
6329
6330
6331
6332
6333
6334
6335
6336
6337
6338
6339
6340
6341
6342
6343
6344
6345
6346
6347
6348
6349
6350
6351
6352
6353
6354
6355
6356
6357
6358
6359
6360
6361
6362
6363
6364
6365
6366
6367
6368
6369
6370
6371
6372
6373
6374
6375
6376
6377
6378
6379
6380
6381
6382
6383
6384
6385
6386
6387
6388
6389
6390
6391
6392
6393
6394
6395
6396
6397
6398
6399
6400
6401
6402
6403
6404
6405
6406
6407
6408
6409
6410
6411
6412
6413
6414
6415
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429
6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446
6447
6448
6449
6450
6451
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474
6475
6476
6477
6478
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498
6499
6500
6501
6502
6503
6504
6505
6506
6507
6508
6509
6510
6511
6512
6513
6514
6515
6516
6517
6518
6519
6520
6521
6522
6523
6524
6525
6526
6527
6528
6529
6530
6531
6532
6533
6534
6535
6536
6537
6538
6539
6540
6541
6542
6543
6544
6545
6546
6547
6548
6549
6550
6551
6552
6553
6554
6555
6556
6557
6558
6559
6560
6561
6562
6563
6564
6565
6566
6567
6568
6569
6570
6571
6572
6573
6574
6575
6576
6577
6578
6579
6580
6581
6582
6583
6584
6585
6586
6587
6588
6589
6590
6591
6592
6593
6594
6595
6596
6597
6598
6599
6600
6601
6602
6603
6604
6605
6606
6607
6608
6609
6610
6611
6612
6613
6614
6615
6616
6617
6618
6619
6620
6621
6622
6623
6624
6625
6626
6627
6628
6629
6630
6631
6632
6633
6634
6635
6636
6637
6638
6639
6640
6641
6642
6643
6644
6645
6646
6647
6648
6649
6650
6651
6652
6653
6654
6655
6656
6657
6658
6659
6660
6661
6662
6663
6664
6665
6666
6667
6668
6669
6670
6671
6672
6673
6674
6675
6676
6677
6678
6679
6680
6681
6682
6683
6684
6685
6686
6687
6688
6689
6690
6691
6692
6693
6694
6695
6696
6697
6698
6699
6700
6701
6702
6703
6704
6705
6706
6707
6708
6709
6710
6711
6712
6713
6714
6715
6716
6717
6718
6719
6720
6721
6722
6723
6724
6725
6726
6727
6728
6729
6730
6731
6732
6733
6734
6735
6736
6737
6738
6739
6740
6741
6742
6743
6744
6745
6746
6747
6748
6749
6750
6751
6752
6753
6754
6755
6756
6757
6758
6759
6760
6761
6762
6763
6764
6765
6766
6767
6768
6769
6770
6771
6772
6773
6774
6775
6776
6777
6778
6779
6780
6781
6782
6783
6784
6785
6786
6787
6788
6789
6790
6791
6792
6793
6794
6795
6796
6797
6798
6799
6800
6801
6802
6803
6804
6805
6806
6807
6808
6809
6810
6811
6812
6813
6814
6815
6816
6817
6818
6819
6820
6821
6822
6823
6824
6825
6826
6827
6828
6829
6830
6831
6832
6833
6834
6835
6836
6837
6838
6839
6840
6841
6842
6843
6844
6845
6846
6847
6848
6849
6850
6851
6852
6853
6854
6855
6856
6857
6858
6859
6860
6861
6862
6863
6864
6865
6866
6867
6868
6869
6870
6871
6872
6873
6874
6875
6876
6877
6878
6879
6880
6881
6882
6883
6884
6885
6886
6887
6888
6889
6890
6891
6892
6893
6894
6895
6896
6897
6898
6899
6900
6901
6902
6903
6904
6905
6906
6907
6908
6909
6910
6911
6912
6913
6914
6915
6916
6917
6918
6919
6920
6921
6922
6923
6924
6925
6926
6927
6928
6929
6930
6931
6932
6933
6934
6935
6936
6937
6938
6939
6940
6941
6942
6943
6944
6945
6946
6947
6948
6949
6950
6951
6952
6953
6954
6955
6956
6957
6958
6959
6960
6961
6962
6963
6964
6965
6966
6967
6968
6969
6970
6971
6972
6973
6974
6975
6976
6977
6978
6979
6980
6981
6982
6983
6984
6985
6986
6987
6988
6989
6990
6991
6992
6993
6994
6995
6996
6997
6998
6999
7000
7001
7002
7003
7004
7005
7006
7007
7008
7009
7010
7011
7012
7013
7014
7015
7016
7017
7018
7019
7020
7021
7022
7023
7024
7025
7026
7027
7028
7029
7030
7031
7032
7033
7034
7035
7036
7037
7038
7039
7040
7041
7042
7043
7044
7045
7046
7047
7048
7049
7050
7051
7052
7053
7054
7055
7056
7057
7058
7059
7060
7061
7062
7063
7064
7065
7066
7067
7068
7069
7070
7071
7072
7073
7074
7075
7076
7077
7078
7079
7080
7081
7082
7083
7084
7085
7086
7087
7088
7089
7090
7091
7092
7093
7094
7095
7096
7097
7098
7099
7100
7101
7102
7103
7104
7105
7106
7107
7108
7109
7110
7111
7112
7113
7114
7115
7116
7117
7118
7119
7120
7121
7122
7123
7124
7125
7126
7127
7128
7129
7130
7131
7132
7133
7134
7135
7136
7137
7138
7139
7140
7141
7142
7143
7144
7145
7146
7147
7148
7149
7150
7151
7152
7153
7154
7155
7156
7157
7158
7159
7160
7161
7162
7163
7164
7165
7166
7167
7168
7169
7170
7171
7172
7173
7174
7175
7176
7177
7178
7179
7180
7181
7182
7183
7184
7185
7186
7187
7188
7189
7190
7191
7192
7193
7194
7195
7196
7197
7198
7199
7200
7201
7202
7203
7204
7205
7206
7207
7208
7209
7210
7211
7212
7213
7214
7215
7216
7217
7218
7219
7220
7221
7222
7223
7224
7225
7226
7227
7228
7229
7230
7231
7232
7233
7234
7235
7236
7237
7238
7239
7240
7241
7242
7243
7244
7245
7246
7247
7248
7249
7250
7251
7252
7253
7254
7255
7256
7257
7258
7259
7260
7261
7262
7263
7264
7265
7266
7267
7268
7269
7270
7271
7272
7273
7274
7275
7276
7277
7278
7279
7280
7281
7282
7283
7284
7285
7286
7287
7288
7289
7290
7291
7292
7293
7294
7295
7296
7297
7298
7299
7300
7301
7302
7303
7304
7305
7306
7307
7308
7309
7310
7311
7312
7313
7314
7315
7316
7317
7318
7319
7320
7321
7322
7323
7324
7325
7326
7327
7328
7329
7330
7331
7332
7333
7334
7335
7336
7337
7338
7339
7340
7341
7342
7343
7344
7345
7346
7347
7348
7349
7350
7351
7352
7353
7354
7355
7356
7357
7358
7359
7360
7361
7362
7363
7364
7365
7366
7367
7368
7369
7370
7371
7372
7373
7374
7375
7376
7377
7378
7379
7380
7381
7382
7383
7384
7385
7386
7387
7388
7389
7390
7391
7392
7393
7394
7395
7396
7397
7398
7399
7400
7401
7402
7403
7404
7405
7406
7407
7408
7409
7410
7411
7412
7413
7414
7415
7416
7417
7418
7419
7420
7421
7422
7423
7424
7425
7426
7427
7428
7429
7430
7431
7432
7433
7434
7435
7436
7437
7438
7439
7440
7441
7442
7443
7444
7445
7446
7447
7448
7449
7450
7451
7452
7453
7454
7455
7456
7457
7458
7459
7460
7461
7462
7463
7464
7465
7466
7467
7468
7469
7470
7471
7472
7473
7474
7475
7476
7477
7478
7479
7480
7481
7482
7483
7484
7485
7486
7487
7488
7489
7490
7491
7492
7493
7494
7495
7496
7497
7498
7499
7500
7501
7502
7503
7504
7505
7506
7507
7508
7509
7510
7511
7512
7513
7514
7515
7516
7517
7518
7519
7520
7521
7522
7523
7524
7525
7526
7527
7528
7529
7530
7531
7532
7533
7534
7535
7536
7537
7538
7539
7540
7541
7542
7543
7544
7545
7546
7547
7548
7549
7550
7551
7552
7553
7554
7555
7556
7557
7558
7559
7560
7561
7562
7563
7564
7565
7566
7567
7568
7569
7570
7571
7572
7573
7574
7575
7576
7577
7578
7579
7580
7581
7582
7583
7584
7585
7586
7587
7588
7589
7590
7591
7592
7593
7594
7595
7596
7597
7598
7599
7600
7601
7602
7603
7604
7605
7606
7607
7608
7609
7610
7611
7612
7613
7614
7615
7616
7617
7618
7619
7620
7621
7622
7623
7624
7625
7626
7627
7628
7629
7630
7631
7632
7633
7634
7635
7636
7637
7638
7639
7640
7641
7642
7643
7644
7645
7646
7647
7648
7649
7650
7651
7652
7653
7654
7655
7656
7657
7658
7659
7660
7661
7662
7663
7664
7665
7666
7667
7668
7669
7670
7671
7672
7673
7674
7675
7676
7677
7678
7679
7680
7681
7682
7683
7684
7685
7686
7687
7688
7689
7690
7691
7692
7693
7694
7695
7696
7697
7698
7699
7700
7701
7702
7703
7704
7705
7706
7707
7708
7709
7710
7711
7712
7713
7714
7715
7716
7717
7718
7719
7720
7721
7722
7723
7724
7725
7726
7727
7728
7729
7730
7731
7732
7733
7734
7735
7736
7737
7738
7739
7740
7741
7742
7743
7744
7745
7746
7747
7748
7749
7750
7751
7752
7753
7754
7755
7756
7757
7758
7759
7760
7761
7762
7763
7764
7765
7766
7767
7768
7769
7770
7771
7772
7773
7774
7775
7776
7777
7778
7779
7780
7781
7782
7783
7784
7785
7786
7787
7788
7789
7790
7791
7792
7793
7794
7795
7796
7797
7798
7799
7800
7801
7802
7803
7804
7805
7806
7807
7808
7809
7810
7811
7812
7813
7814
7815
7816
7817
7818
7819
7820
7821
7822
7823
7824
7825
7826
7827
7828
7829
7830
7831
7832
7833
7834
7835
7836
7837
7838
7839
7840
7841
7842
7843
7844
7845
7846
7847
7848
7849
7850
7851
7852
7853
7854
7855
7856
7857
7858
7859
7860
7861
7862
7863
7864
7865
7866
7867
7868
7869
7870
7871
7872
7873
7874
7875
7876
7877
7878
7879
7880
7881
7882
7883
7884
7885
7886
7887
7888
7889
7890
7891
7892
7893
7894
7895
7896
7897
7898
7899
7900
7901
7902
7903
7904
7905
7906
7907
7908
7909
7910
7911
7912
7913
7914
7915
7916
7917
7918
7919
7920
7921
7922
7923
7924
7925
7926
7927
7928
7929
7930
7931
7932
7933
7934
7935
7936
7937
7938
7939
7940
7941
7942
7943
7944
7945
7946
7947
7948
7949
7950
7951
7952
7953
7954
7955
7956
7957
7958
7959
7960
7961
7962
7963
7964
7965
7966
7967
7968
7969
7970
7971
7972
7973
7974
7975
7976
7977
7978
7979
7980
7981
7982
7983
7984
7985
7986
7987
7988
7989
7990
7991
7992
7993
7994
7995
7996
7997
7998
7999
8000
8001
8002
8003
8004
8005
8006
8007
8008
8009
8010
8011
8012
8013
8014
8015
8016
8017
8018
8019
8020
8021
8022
8023
8024
8025
8026
8027
8028
8029
8030
8031
8032
8033
8034
8035
8036
8037
8038
8039
8040
8041
8042
8043
8044
8045
8046
8047
8048
8049
8050
8051
8052
8053
8054
8055
8056
8057
8058
8059
8060
8061
8062
8063
8064
8065
8066
8067
8068
8069
8070
8071
8072
8073
8074
8075
8076
8077
8078
8079
8080
8081
8082
8083
8084
8085
8086
8087
8088
8089
8090
8091
8092
8093
8094
8095
8096
8097
8098
8099
8100
8101
8102
8103
8104
8105
8106
8107
8108
8109
8110
8111
8112
8113
8114
8115
8116
8117
8118
8119
8120
8121
8122
8123
8124
8125
8126
8127
8128
8129
8130
8131
8132
8133
8134
8135
8136
8137
8138
8139
8140
8141
8142
8143
8144
8145
8146
8147
8148
8149
8150
8151
8152
8153
8154
8155
8156
8157
8158
8159
|
*** START OF THE PROJECT GUTENBERG EBOOK 49769 ***
TRANSCRIBER'S NOTE:
In transcribing this book, the proofreaders found and corrected several
minor typographical errors which did not affect the sense of the text.
In the caption to Figure 541, the equation for the voltage of a Weston cell
at different temperatures was missing a digit "1" and this has been
corrected. There is a reference to a Figure 619 but no such figure exists
in the original text. There are references to a Figure 119 and a Figure
443; these presumably exist in one of the preceding volumes of the series.
Throughout, the use of italic type is indicated by _underscores_. In
equations, superscripts are indicated by a caret and braces, as in X^{2}
for "X squared". Subscripts are indicated by underscore and braces, as in
E_{t} to mean "E sub t".
THE THOUGHT IS IN THE QUESTION THE INFORMATION IS IN THE ANSWER
HAWKINS
ELECTRICAL GUIDE
NUMBER THREE
QUESTIONS
ANSWERS
&
ILLUSTRATIONS
A PROGRESSIVE COURSE OF STUDY
FOR ENGINEERS, ELECTRICIANS, STUDENTS
AND THOSE DESIRING TO ACQUIRE A
WORKING KNOWLEDGE OF
ELECTRICITY AND ITS APPLICATIONS
A PRACTICAL TREATISE
by
HAWKINS AND STAFF
THEO. AUDEL & CO. 72 FIFTH AVE. NEW YORK
COPYRIGHTED, 1914,
by
THEO. AUDEL & CO.,
New York.
Printed in the United States.
TABLE OF CONTENTS
GUIDE NO. 3.
GALVANOMETERS 431 to 464
Action of compass needle--simple galvanometer--difference between
galvanoscope and galvanometer--sensibility--action of short and long coil
galvanometers--classes of galvanometer--astatic galvanometer--tangent
galvanometer--graduation of tangent galvanometer scale--table of
galvanometer constants--mechanical explanation of tangent law--sine
galvanometer--table of natural sines and tangents--comparison of
sine and tangent galvanometers--differential galvanometer--ballistic
galvanometer--kick--damping effect--use of mirrors in galvanometers--lamp
and scale--damping--D'Arsonval galvanometer: construction, operation;
uses--galvanometer constant or figure of merit--shunts.
TESTING AND TESTING APPARATUS 465 to 536
Pressure measurement--Clark cell--Weston cadmium cell--pressure
measurement error with ordinary voltmeter--International volt--hydraulic
analogy of amperes--coulombs--current measurement--International
ampere--voltameters--Ohm's law and the ohm--International ohm--ohm
table--practical standards of resistance--various methods of resistance
measurement--direct deflection method--method of substitution--resistance
box--fall of potential method--differential galvanometer method--drop
method--voltmeter method--Wheatstone bridge--usual arrangement of
resistances of Wheatstone bridge--ratio coils of Wheatstone bridge--the
decade plan--two plug arrangement--"plug out" and "plug in" type of
resistance box--testing sets--direct deflection method with Queen Acme
set--ohmmeter--fall of potential method with Queen Acme set--apparatus
for measuring low resistances--how to check a voltmeter--Kelvin wire
bridge--internal resistance measurement--Evershed portable ohmmeter
set--L and N fault finder--ammeter test--diagram of Queen standard
potentiometer--diagrams illustrating loop testing--the Murray loop--the
Varley loop--special loop--the potentiometer--location of opens--to pick
out faulty wires in a cable--voltage of cell measurement with
potentiometer--care of potentiometer--location of faults where the
loop is composed of cables of different cross sections.
AMMETERS, VOLTMETERS, AND WATTMETERS 537 to 572
Definition of ammeter--classification of ammeter and voltmeters--moving
iron type instrument--Keystone voltmeter--winding in ammeters
and volts--connections for series and shunt ammeters--voltmeter
connections--Westinghouse ammeter shunts--various types of
instrument--plunger type instrument--magnetic vane instrument--inclined
coil instrument--Whitney hot wire instruments--principle of
electrostatic instruments--multipliers--portable shunts--Siemens
electro-dynamometer--station instruments--Thompson watt hour meter--how
to read a meter--installation of wattmeters--Westinghouse watt hour
meter--Thompson prepayment watt hour meter--how to test a meter--Sangamo
watt hour meter--Columbia watt hour meter--Duncan watt hour meter.
OPERATION OF DYNAMOS 573 to 596
Before starting a dynamo--adjusting the brushes--brush position--how
to set the brushes--method of soldering cable to carbon brush--brush
contact pressure--direction of rotation--method of winding cables with
marlin--method of assembling core discs--starting a dynamo--tinning block
for electric soldering tool--shunt dynamos in parallel--shunt dynamos
on three wire system--how to start a series machine--the term "build
up"--how to start a shunt or compound machine--"picking up"--indication
of reversed connections--how to correct reversed polarity--finding
the reversed coil--loss of residual magnetism--remedy for reversed
dynamo--attention while running--lead of brushes--method of taking
temperature--lubrication--oils--allowable degree of heating--attention to
brushes and brush gear.
COUPLING OF DYNAMOS 597 to 610
Series and parallel connections--coupling series dynamos in series; in
parallel--equalizer--shunt dynamos in series; in parallel--switching
dynamo into and out of parallel--to cut out a machine--dividing
the lead--compound dynamos in series; in parallel--equalizer
connection--switching a compound dynamo into and out of
parallel--equalizing the load--shunt and compound dynamos in parallel.
DYNAMO FAILS TO EXCITE 611 to 622
Various causes--brushes not properly adjusted--defective
contacts--incorrect adjustment of regulators--speed too low--testing for
break--insufficient residual magnetism; remedy--open circuits--test for
field circuit breakers--probable location of breaks--Watson armature
discs--Fort Wayne commutator truing device--short circuits--Watson
armature--wrong connections--reversed field magnetism.
ARMATURE TROUBLES 623 to 634
Causes--how avoided--various faults--short circuit in individual
coils--location of faulty coil--test for break in armature lead--bar to
bar test for open or short circuit in coil or between segments--short
circuits between adjacent coils--alternate bar test for short circuits
between sections--short circuits between sections through frame or
core of armature; between sections through binding wires--partial short
circuits in armatures--method of testing for breaks--burning of armature
coils--Watson field coils--grounds in armatures--method of locating
grounded armature coil--magneto test for grounded armatures--method of
binding armature winding--breaks in armature circuit.
CARE OF THE COMMUTATOR AND BRUSHES 635 to 652
Conditions for satisfactory operation--oil for commutator--attention
to brushes--Bissell brush gear--two kinds of sparking--commutator
clamp--causes of sparking--bad adjustment of brushes--rocking--bad
condition of brushes--brushes making bad contact--bad condition of
commutator--detection of untrue commutator--high segments--"flats"--causes
of flats; remedy--method of repairing broken joint between commutator
segment and lug--segments loose or knocked in--how to re-turn a
commutator--Bissell commutators--overload of dynamo--method of repairing
large hole burned in two adjacent bars of a commutator--operating dynamos
with metal brushes--indication of excessive voltage--method of smoothing
commutator with a stone--causes of excessive voltage--loose connections,
terminals, etc.,--breaks in armature circuit--sandpaper holder for
commutator--short circuits, in armature circuits; in field--breaks in
field--sandpaper block--short circuits in commutator.
HEATING 653 to 662
Various causes--how detected--procedure--heating, of connections;
of brushes, commutator and armature--excessive heating--ventilated
commutator--self-oiling bearing--some causes of hot bearing--effect of hot
bearings--points relating to hot bearings--operation above rated voltage
and below normal speed--forced system of lubrication--heating of field
magnets--causes of eddy currents in pole pieces--detection of moisture in
field coils--indication of short circuits in field coils.
OPERATION OF MOTORS 663 to 696
Before starting a motor--starting a motor--various starting
resistances--starting boxes--speed regulators--Cutler Hammer starter--time
required to start motor--how to start--sliding contact starters--series
motors on battery circuits--starting a shunt motor--multiple switch
starters--effect of reverse voltage--rheostat with no voltage and
overload release--failure to start--starting panel--Cutler Hammer starting
rheostats--Allen Bradley automatic starter--Monitor starter with relay
for push button control--a remote control of shunt motors--regulation of
motor speed; various methods--Monitor printing press controller--speed
regulation of series motor, by short circuiting sections of the field
winding--varying the speed of shunt and compound motors--Cutler Hammer
multiple switch starter--regulation by armature resistance--Compound
starter--regulation by shunt field resistance--Holzer Cabot instructions
for shunt wound motor--Reliance adjustable speed motor--Cutler Hammer
reversible starter--combined armature and shunt field control--selection
of starters and regulators--Watson commutators--organ blower speed
regulator--General Electric controller--speed regulation of traction
motors--controller of the Rauch and Lang electric vehicles--two motor
regulation--controller connection diagrams--stopping a motor.
CHAPTER XXVI
GALVANOMETERS
If a compass needle be allowed to come to rest in its natural position,
and a current of electricity be passed through a wire just over it from
north to south, the north seeking end of the needle will be deflected
toward the east. If the wire be placed under the needle and the current
continued from north to south the needle will be deflected toward the
west. Again, if the current be passed from north to south over the needle,
and back from south to north under the needle, as shown in fig. 504, the
magnetic effect will be doubled, and the needle deflected proportionately.
Upon these phenomena depend the working of galvanometers.
[Illustration: Fig. 503.--Effect of neighboring current upon a magnetic
needle. Above the needle and parallel to it is a conductor carrying an
electric current, the current flowing in the direction indicated by the
arrow. This causes the north pole of the needle to turn toward the east.
If the conductor be held _below_ the needle, its north pole will turn in
the opposite direction or toward the west. These movements are easily
determined by Ampere's rule as follows: _If a man could swim in the
conductor with the current, and turn to face the needle, then the north
pole of the needle will be deflected toward his left hand_.]
Ques. Describe a simple galvanometer.
Ans. It consists essentially of a magnetic needle suspended within a coil
of wire, and free to swing over the face of a graduated dial.
Ques. What is a galvanoscope and how does it differ from a galvanometer?
Ans. A galvanoscope, as shown in fig. 504, serves merely to indicate the
presence of an electric current without measuring its strength. It is an
indicator of currents where the movement of the needle shows the direction
of the current, and indicates whether it is a strong or a weak one. When
the value of the readings has been determined by experiment or calculation
any galvanoscope becomes a galvanometer.
[Illustration: Fig. 504.--Effect upon a magnetic needle of a neighboring
current in a loop. In this arrangement the same conductor is simply
carried back _beneath_ the needle and hence both the upper and lower
portions tend to turn it in the same direction, while the side branch or
vertical section is ineffective. In accordance with Ampere's swimming
rule, the _upper_ wire causes the N pole of the needle to turn to the
left, while if a man can imagine himself swimming in the lower wire in
the direction of the current, and facing the needle (that is, swimming
on his back), the N pole of the needle will turn to his left--that is to
the east. The effect of the loop then has double the effect of the single
wire in fig. 503.]
Ques. For what use are galvanometers employed?
Ans. They are used for detecting the presence of an electric current, and
for determining its direction and strength.
Ques. How is the direction and strength of the current indicated?
Ans. When a galvanometer is connected in a circuit, the direction of
the current is indicated by the side towards which the north pole of
the needle moves, and the current strength by the extent of the needle's
deflection.
[Illustration: Fig. 505.--Effect upon a magnetic needle of a neighboring
current in a coil. The coil as shown, is equivalent to several loops,
that is, the force tending to deflect the needle is equal to that of a
single loop multiplied by the number of turns. Hence, by using a coil
with a large number of turns, a galvanometer may be made very sensitive
so that the needle will be perceptibly deflected by very feeble currents.
An instrument, as shown in the figure is called a _galvanoscope_. When
it is accurately constructed, and supplied with a scale showing how many
degrees the needle is deflected it is then called a galvanometer.]
Ques. How should a galvanometer be set up before using?
Ans. When no current is flowing, the coil should be parallel to the
magnetic needle when at rest.
Ques. What is a "sensitive" galvanometer?
Ans. One which requires a very small current or pressure to produce a
stated deflection.
It does not follow that a galvanometer which is sensitive for current
measurement will also be sensitive for pressure measurement.
[Illustration: Fig. 506.--Bunnell simple detector galvanometer. It has
middle clamps and scale divided into degrees.]
Ques. Define the term "sensibility."
Ans. With reference to mirror reflecting galvanometers it may be defined
in three ways. First, in _megohms_, the sensibility being the number
of _megohms_ through which one volt will produce a deflection of one
millimeter with the scale at one meter distance. Second, in _micro-volts_,
the sensibility being the number of micro-volts which applied directly
to the terminals of the galvanometer will produce a deflection of one
millimeter on a scale one meter from mirror. The sensibility is best
stated in megohms for high resistance galvanometers and in micro-volts
for low resistance galvanometers, and is frequently given both for
galvanometers for intermediate resistance. Third, in micro-amperes,
the sensibility being the number of micro-amperes that will give one
millimeter deflection with scale at a distance of one meter.
Ques. Upon what does the sensibility depend?
Ans. 1, Upon the number of times the current circulates around the coil,
2, the distance of the needle from the coil, 3, the weight of the needle,
4, the current strength, and 5, the amount of friction produced by its
movement.
[Illustration: Fig. 507.--Breguet upright galvanometer with glass shade.]
[Illustration: Fig. 508.--Bunnell horizontal galvanometer. It has two
coils, one of which is of zero resistance and one of fifty ohms resistance
adapting it to a variety of test.]
The needle is usually quite small, and often a compound one. In very
sensitive galvanometers, the coils are wound with thousands of turns
of very fine wire, and shunts are generally used in connection with
them.
NOTE.--Strong currents must not be passed through very sensitive
galvanometers, for even if they be not ruined, the deflections of the
needle will be too large to give accurate measurements. In such cases the
galvanometer is used with a shunt, or coil of wire arranged so that the
greater part of the current will flow through it, and only a small portion
through the galvanometer.
Ques. What two kinds of coil are used?
Ans. The short coil and the long coil.
Ques. What is the difference between a short coil and a long coil
galvanometer?
Ans. A short coil galvanometer has a coil consisting of a few turns of
heavy wire; a long coil galvanometer is wound with a large number of turns
of fine wire.
[Illustration: Fig. 509.--Bunnell galvanometer for measurements of
instruments, lines, batteries, wires and any object from 1/100 to 10,000
ohms or more.]
Ques. What is the action of short and long coil galvanometers?
Ans. With a given current, the total magnetizing force which deflects
the needle is the same, but with a short coil, it is produced by a
large current circulating around a few turns, instead of a small current
circulating around thousands of turns as in the long coil. The short coil
being of low resistance is used to measure the current, and the long coil
with high resistance, is suitable for measuring the pressure. Hence,
a short coil instrument with its scale directly graduated in amperes
is an _ammeter_, and the long coil type with graduation in volts is a
_voltmeter_.
Classes of Galvanometer.--There are numerous kinds of galvanometer
designed to meet the varied requirements. According to construction,
galvanometers may be divided into two classes, as those having:
1. Movable magnet and stationary coil;
2. Stationary magnet and movable coil.
[Illustration: Fig. 510.--Astatic needles. Two magnetic needles of equal
moment are mounted in opposition on a light support. The whole system is
suspended by a delicate fibre, and when placed in a uniform magnetic field
such as that of the earth, there will be no tendency to assume any fixed
direction, the only restraining influence on the needles being that due
to torsion in the suspension fibre.]
Either type may be constructed with short or long coil, and there are
several ways in which the deflections are indicated. The principal forms
of galvanometer are as follows:
1. Astatic;
2. Tangent;
3. Sine;
4. Differential;
5. Ballistic;
6. D'Arsonval.
Astatic Galvanometer.--It has been pointed out how a compass needle is
affected when a wire carrying a current is held over or under it, the
needle being turned in one direction in the first instance, and in the
opposite direction for the second position of the wire.
[Illustration: Fig. 511.--Connections of single coil astatic needles. The
coil surrounds the lower needle and the direction of the current between
the two needles tends to turn them the same way.]
The earth's magnetism naturally holds the compass needle north and south.
The magnetic field encircling the wire, being at right angles to the
needle (when the wire itself is parallel therewith), operates to turn
it from its normal position, north and south, so as to set it partially
east and west. However, on account of the fact that the earth's magnetism
does exert some force tending to hold the needle north and south, it
is evident that no matter how strong the current, the latter can never
succeed in turning the needle entirely east and west. The accomplishment
of this is further prevented by the reason of the points of the needle,
where the magnetic effect is greatest, quickly passing out of the reach
of the magnetic field, where it is now practically operated on only in a
slight degree. Thus it would take quite a powerful current to hold the
needle deflected any appreciable distance. The use of a shorter needle
is, therefore, more desirable.
It is evident in this style of instrument that the effect of the current
cannot be accurately measured, because it acts in opposition to the
earth's magnetism, and as this is constantly varying, some method must
be employed which will either destroy the earth's magnetism or else
neutralize it.
In the astatic galvanometer, the earth's magnetism is neutralized by
means of _astatic needles_. These consist of a combination of two magnetic
needles of equal size and strength, connected rigidly together with their
poles pointing in opposite and parallel directions, as shown in fig.
510. As the north pole of the earth attracts the south pole of one of the
needles, it repels with equal strength the north pole of the other needle,
hence, the combination is independent of the earth's magnetism and will
remain at rest in any position.
[Illustration: Fig. 512.--Connections of double coil astatic needles. With
this arrangement, the direction of current in both coils will tend to turn
the system in the same direction, making the needles more sensitive than
with a single coil as in fig. 511.]
If one of the needles be surrounded by a coil, as shown in fig. 511,
the magnetic effect of the current will be correctly indicated by the
deflection of the needle.
Sometimes each needle is surrounded by a coil, as in fig. 512, the coils
being so connected that the direction of current in each will tend to
deflect the needles in the same direction.
Ques. For what use is the astatic galvanometer adapted?
Ans. For the detection of small currents.
It is used in the "nil" or zero methods, in which the current between
the points to which the galvanometer is connected is reduced to zero.
[Illustration: Fig. 513.--Queen reflecting astatic galvanometer. It
is mounted on a mahogany base with levelling screws. A plain mirror is
attached above the upper needle. The entire combination of mirror and
needles is suspended by unspun silk from the interior of a brass tube,
which also carries a weak controlling magnet. A dial 4 inches in diameter
and graduated in degrees, enables the deflections of the needle to be
accurately read. The mirror can be used with a reading telescope and
scale, or by means of a lantern, the image of a slit may be reflected from
the mirror to a screen. Resistance, .5 to 1,000 ohms.]
Ques. Upon what does the movement of the needles depend?
Ans. Upon the combined effect of the magnetic attraction of the current
which tends to deflect the needles, and the torsion in the suspension
fibre which tends to keep the needle at the zero position.
Ques. Does the astatic galvanometer give correct readings for different
values of the current?
Ans. When the deflections are _small_ (that is, less than 10° or 15°),
they are very nearly proportional to the strength of the currents that
produce them.
Thus, if a current produce a deflection of 6° it is known to be
approximately three times as strong as a current which only turns the
needle through 2°. But this approximate proportion ceases to be true
if the deflection be more than 15° or 20°.
[Illustration: Fig. 514.--Central Scientific Co. tangent galvanometer.
A 9 inch brass ring is mounted on a mahogany base which rotates on a
tripod provided with levelling screws. The needle has an aluminum pointer
and jewelled bearing. The winding consists of 300 turns of magnet wire
so connected to the plugs in front that 20, 40, 80, or 160 turns or any
combination of these numbers may be used. For heavy currents a band of
copper is used by connecting to the extra pair of binding posts in the
rear of the instrument.]
Ques. Why does the instrument not give accurate readings for large
deflections?
Ans. The needles are not so advantageously acted upon by the current,
since the poles are no longer within the coils, but protrude at the side.
Moreover, the needles being oblique to the force acting on them, part only
of the force is turning them against the directive force of the fibre;
the other part is uselessly pulling or pushing them along their length.
[Illustration: Fig. 515.--Bunnell tangent galvanometer. This instrument
is mounted on a circular hard rubber base, 7-3/8 inches diameter, provided
with levelling screws and anchoring points. The galvanometer consists of a
magnetized needle 7/8 inch in length, suspended at the center of a rubber
ring six inches in diameter, containing the coils. There are five coils of
0, 1, 10, 50 and 150 ohms resistance. The first is a stout copper band of
inappreciable resistance; the others are of different sized copper wires,
carefully insulated. Five terminals are provided, marked, respectively,
0, 1, 10, 50 and 150. The ends of the coils are so arranged that the plug
inserted at the terminal marked 50 puts in circuit all the coils; marked
at the terminal 50--all except the 150 ohm coil; and so on, till at the
zero terminal only the copper band is in circuit. Fixed to the needle,
which is balanced on jewel and point, is an aluminum pointer at right
angles, extending across a five inch dial immediately beneath. One side
of the dial is divided into degrees; on the other side, the graduations
correspond to the tangent of the angles of deflection.]
Ques. How may correct readings be obtained?
Ans. The instrument may be calibrated, that is, it may be ascertained by
special measurements, or by comparison with a standard instrument, the
amounts of deflection corresponding to particular current strengths.
Thus, if it be once known that a deflection of 32° on a particular
galvanometer is produced by a current of 1/100 of an ampere, then a
current of that strength will _always_ produce on that instrument the
same deflection, unless from any accident the torsion force or the
intensity of the magnetic field be altered.
[Illustration: Fig. 516.--Tangent galvanometer. It consists of a short
magnetic needle suspended at the center of a coil of large diameter and
small cross section. In practice, the diameter of the coil is about 17
times the length of the needle. If the instrument be so placed that, when
there is no current in the coil, the suspended magnet lies in the plane
of the coil, that is, if the plane of the coil be set in the magnetic
meridian, then _the current passing through the coil is proportional to
the tangent of the angle by which the magnet is deflected from the plane
of the coil_, or zero position--hence the name: "tangent galvanometer."]
The Tangent Galvanometer.--It is not possible to construct a galvanometer
in which the _angle_ (as measured in degrees of arc) through which the
needle is deflected is proportional throughout its whole range to the
strength of the current. But it is possible to construct a very simple
galvanometer in which the _tangent of the angle of deflection_ shall be
accurately proportional to the strength of the current.
[Illustration: Fig. 517.--Horizontal section through middle of tangent
galvanometer, showing magnetic whirls around the coil and corresponding
deflection of needle.]
[Illustration: Fig. 518.--Diagram of forces acting on the needle of a
tangent galvanometer.]
A simple form of tangent galvanometer is shown in fig. 516. The coil of
this instrument consists of a simple circle of stout copper wire from
ten to fifteen inches in diameter. At the center is delicately suspended
a magnetized steel needle not exceeding one inch in length, and usually
furnished with a light index of aluminum. When the galvanometer is in use,
the plane of the ring must be vertical and in the magnetic meridian. A
horizontal section through the middle of the instrument is shown in fig.
517. For simplicity, the coil is supposed to have but a single turn of
wire, the circles surrounding the wire representing the magnetic lines
of force. By extending the lines of force until they reach the needle,
it will be seen that with a short needle, the deflecting force acts in an
east and west direction when the galvanometer is placed with its coil in
the magnetic meridian.
If, in fig. 518, _ab_ represent the deflecting force acting on the N end
of the needle, the component of this force that acts at a right angle to
the needle will be
_ab_ cos _x_
in which, _x_ is the angle of the deflection.
The controlling force is
_ad_ = H
and when the needle is in equilibrium, the component _ae_ = H sin _x_ is
equal and opposite to _ac_, hence
_ab_ cos _x_ = H sin _x_
from which
_ab_ = H(sin _x_ / cos _x_) = H tan _x_
Since _ab_ is proportional to the current,
_ab_ = _k_ C = H tan _x_
in which _k_ is a constant depending upon the instrument. For any other
current C',
_k_ C' = H tan _x'_
hence
C: C' = tan _x_ : tan _x'_
This means that the currents passing through the coil of a tangent
galvanometer are proportional, not to the angle of deflection, but to the
tangent of that angle.
[Illustration: Fig. 519.--Diagram illustrating the tangent law.
This is the law of the combined action of two magnetic fields upon a
magnetic needle. If two magnetic fields be at right angles in direction
as indicated in the figure, the resultant field is obtained by the
parallelogram of forces and it makes an angle [theta] with one of the
component fields such that tan [theta] = M + H where M and H are the
strengths of the component fields. In the tangent galvanometer this
principle is employed in the measurement of currents. A magnetic needle is
pivoted in a field of known strength. The current to be measured is passed
round a coil (or coils) which generates a field at right angles to the
original field. The needle then lies along the direction of the resultant
field, and by finding the tangent of its angle of deflection, and knowing
the field strength produced by unit current in the coil, the current
strength can be found.]
[Illustration: Fig. 520.--Graduation of tangent galvanometer scale with
divisions representing tangent values. In the figure let a tangent OT
be drawn to the circle, and along this line let any number of equal
divisions be set off, beginning at O. From these points draw lines back
to the center. The circle will thus be divided into a number of spaces, of
which those near O are nearly equal, but which get smaller and smaller as
they recede from O. These unequal spaces correspond to equal increments
of the tangent. If the scale were divided thus, the readings would be
proportional to the tangents.]
Ques. Upon what does the sensibility of a tangent galvanometer depend?
Ans. It is directly proportional to the number of turns of the coil and
inversely proportional to the diameter of the coil.
Ques. How may the tangent galvanometer be used as an ammeter?
Ans. The strength of the current may be calculated in amperes by the
formula given below when the dimensions of the instrument are known.
The needle is supposed to be subject to only the earth's magnetism and to
move in a horizontal plane. The current is calculated as follows:
(1) amperes = ((H × _r_)/N) tan _x_
in which
H = constant from table below;
r = radius of coil;
N = number of turns of coil;
x = angle of deflection of needle.
The constant H, given in the following table represents the horizontal
force of the earth's magnetism for the place where the galvanometer is
used. Each value has been multiplied by (2[pi])/10 so that the formula (1)
for amperes is correct as given.
Table of Galvanometer Constants.--Values of H.
Boston | .699|
Chicago | .759|
Denver | .919|
Jacksonville | 1.094|
London | .745|
Minneapolis | .681|
New York | .744|
New Haven | .731|
Philadelphia | .783|
Portland, Me. | .674|
San Francisco | 1.021|
St. Louis | .871|
Washington | .810|
[Illustration: Fig. 521.--Mechanical explanation of the tangent law.
Construct an apparatus as shown in the figure. The short wooden block,
NS, represents the magnetic needle. This piece of wood turns around its
center, C, which may be an ordinary nail. It will now be seen that two
different forces act upon N; namely, the weight, G (one or two ounces),
and the changeable weights which are placed in the scoop, W (made of
cardboard). The height of the roll, or wheel, R, is such that the cord,
RN, runs horizontally, when NS stands vertically, i.e., when there is no
weight in the little scoop. If the wheel, R, be placed sufficiently far
from NS, the string RN, will always remain almost horizontal, even if NS
be deviated. The thin hand on NS moves over a vertical scale, which is
divided into equal parts, as shown. This scale may be made of cardboard.
If the hand point to division 1 when one ounce is placed in the scoop,
it will point to 2 for two ounces, to 3 for three ounces, etc. At 45°
the needle is deviated at its greatest angle, and this is, therefore, the
sensitivity angle of the tangent galvanometer. The deviating values are,
therefore, proportionate to the scale parts 01, 02, and 03, and so on;
and, inasmuch as these themselves are tangents, the tangent law will hold
good.]
Ques. How is the tangent galvanometer constructed to give direct readings?
Ans. To obviate reference to a table, the circular scale of the instrument
is sometimes graduated into tangent values, as in fig. 520, instead of
being divided into equal degrees.
[Illustration: Fig. 522.--Queen tangent and sine galvanometer. This
instrument properly adjusted can be used as a standard instrument for
laboratory work. The brass ring is 12 inches in diameter, and the grooves
in which the wire is wound are carefully turned so as to be of true
rectangular cross section, thus allowing the constant of the instrument
to be accurately calculated and compared with the constant as obtained by
other methods. The compass box is 5 inches in diameter and is so held in
position that it may be raised or lowered, rotated on its vertical axis,
shifted out of the plane of the coil, etc., thus enabling the operator
to acquire proficiency with the instrument and to meet all cases of
derangement possible. The dial is graduated to single degrees, and the
needle is suspended by a very light cocoon fibre. The whole instrument
can be turned about its vertical axis, and a quadrant graduated in degrees
upon the base allows the amount of rotation to be accurately measured, and
the laws of the sine galvanometer investigated. The instrument is wound
to measure .25 ampere to 8 amperes.]
Ques. What is the objection to the scale with tangent values?
Ans. It is more difficult to divide an arc into tangent lines with
accuracy than into equal degrees.
Ques. What disadvantage has the tangent galvanometer?
Ans. The coil being much larger than the needle, and hence far away from
it, reduces the sensitiveness of the instrument.
The Sine Galvanometer.--This type of instrument has a vertical coil which
may be rotated around a vertical axis, so that it can be made to follow
the magnetic needle in its deflections.
In the sine galvanometer, the coil is moved so as to follow the needle
until it is parallel with the coil. Under these circumstances, the
strength of the deflecting current is proportional to sine of angle
of deflection.
[Illustration: Fig. 523.--Central Scientific Co. universal tangent
galvanometer. This instrument may be used as a tangent, Gaugain,
Helmholtz-Gaugain, sine, cosine, Wiedemann or detector galvanometer. The
coils, which slide on a beam parallel to the one carrying the needle box,
are wound on brass rings 12 inches in diameter. On each ring are wound two
coils of 48 turns each, connected to separate binding posts, and double
wound so as to be of equal resistance. The coils and needle box are each
provided with an indicator for reading their position on the scale. The
needle box is swivelled and removable and one coil may be rotated about
its vertical axis and its position read on a disc graduated in degrees.
Currents may be measured ranging from .000002 ampere to 100 amperes.]
Ques. Describe the construction of a sine galvanometer.
Ans. A form of sine galvanometer is shown in fig. 524. The vertical wire
coil is seen at M. A needle of any length less than the diameter of the
coil M, moves over the graduated circle N. The coil M, and graduated
circle N may be rotated on a vertical axis, and the amount of angular
movement necessary to bring the needle to zero, measured on the graduated
circle H.
Ques. How is the current strength measured?
Ans. It is proportional to the _sine_ of the angle measured on the
horizontal circle H, through which it is necessary to turn the coil M,
from the plane of the earth's magnetic meridian to the plane of the needle
when it is not further deflected by the current.
[Illustration: Fig. 524.--Sine galvanometer. It differs from the tangent
galvanometer in that the vertical coil and magnetic needle are mounted
upon a standard free to revolve around a vertical axis, with provision
for determining the angular position of the coil. The needle may be of any
length shorter than the diameter of the coil. In the figure the parts are:
M, coil; N, graduated dial of magnetic needle; H, graduated dial by which
the amount of rotation necessary to bring the needle to zero is measured;
E, terminals of the coil; O, upright standard carrying coil and graduated
dial of magnetic needle; C, base with levelling screws.]
Ques. How is the sine galvanometer operated?
Ans. In using the instrument, after the needle has been set to zero,
the current is sent through the coil, producing a deflection of the
needle. The coil is then rotated to follow the motion of the needle, the
current being kept constant, the rotation being continued until the zero
on the upper dial again registers with the needle. The current then is
proportional to the sine of the angle through which the coil has been
turned, as determined by the lower dial.
Ques. Has the sine galvanometer a large range?
Ans. For a given controlling field, it does not admit of a very large
range of current measurement, since, for large deflection, on rotating
the coil the position of instability is soon reached.
TABLE OF NATURAL SINES AND TANGENTS
Angle| Sin.| Tan.|
0°| .0000| .0000|
1 | .0175| .0175|
2 | .0349| .0349|
3 | .0523| .0524|
4 | .0698| .0699|
5 | .0871| .0875|
6 | .1045| .1051|
7 | .1219| .1228|
8 | .1392| .1405|
9 | .1564| .1564|
10°| .1736| .1763|
11 | .1908| .1944|
12 | .2079| .2126|
13 | .2250| .2309|
14 | .2419| .2493|
15 | .2588| .2679|
16 | .2756| .2867|
17 | .2924| .3057|
18 | .3090| .3249|
19 | .3256| .3443|
20°| .3420| .3640|
21 | .3584| .3839|
22 | .3746| .4040|
23 | .3907| .4245|
24 | .4067| .4452|
25 | .4226| .4663|
26 | .4384| .4877|
27 | .4540| .5095|
28 | .4695| .5317|
29 | .4848| .5543|
30°| .5000| .5774|
31 | .5150| .6009|
32 | .5299| .6249|
33 | .5446| .6494|
34 | .5592| .6745|
35 | .5736| .7002|
36 | .5878| .7265|
37 | .6018| .7536|
38 | .6157| .7813|
39 | .6293| .8098|
40°| .6428| .8391|
41 | .6561| .8693|
42 | .6691| .9004|
43 | .6820| .9325|
44 | .6947| .9657|
45 | .7071| 1.0000|
46 | .7193| 1.0355|
47 | .7314| 1.0724|
48 | .7431| 1.1106|
49 | .7547| 1.1504|
50°| .7660| 1.1918|
51 | .7771| 1.2349|
52 | .7880| 1.2799|
53 | .7986| 1.3270|
54 | .8090| 1.3764|
55 | .8192| 1.4281|
56 | .8290| 1.4826|
57 | .8387| 1.5399|
58 | .8480| 1.6003|
59 | .8572| 1.6643|
60°| .8660| 1.7321|
61 | .8746| 1.8040|
62 | .8829| 1.8807|
63 | .8910| 1.9626|
64 | .8988| 2.0503|
65 | .9063| 2.1445|
66 | .9135| 2.2460|
67 | .9205| 2.3559|
68 | .9272| 2.4751|
69 | .9339| 2.6051|
70°| .9397| 2.7475|
71 | .9455| 2.9042|
72 | .9511| 3.0772|
73 | .9563| 3.2709|
74 | .9613| 3.4874|
75 | .9659| 3.7321|
76 | .9703| 4.0108|
77 | .9744| 4.3315|
78 | .9781| 4.7046|
79 | .9816| 5.1446|
80°| .9848| 5.6713|
81 | .9877| 6.3138|
82 | .9903| 7.1154|
83 | .9925| 8.1443|
84 | .9945| 9.5144|
85 | .9962| 11.43|
86 | .9976| 14.30|
87 | .9986| 19.08|
88 | .9994| 28.64|
89 | .9998| 57.29|
Ques. What is the position of instability?
Ans. The position of the needle beyond which the rotation of the coil will
cause it to turn all the way round.
Ques. How may the range be increased?
Ans. By an adjustable controlling field or a shunt.
Ques. What advantage has the sine galvanometer over the tangent instrument?
Ans. Its advantage is in the case where the relative values of two
or more currents are required to be measured, or where the constant
of the instrument is obtained by comparison with a standard measuring
instrument and not calculated from the dimensions of the coil, because all
galvanometers thus used follow the sine law independently of the shape of
the coil, while only circular coils will follow the sine law.
[Illustration: Fig. 525.--Differential galvanometer. It consists of two
coils of wire, so wound as to have opposite magnetic effects on a magnetic
needle suspended centrally between them. The needle of a differential
galvanometer shows no deflection when two equal currents are sent through
the coils in opposite directions, since, under these conditions, each
coil neutralizes the effect of the other. Sometimes the current is so
sent through the two coils, that each coil deflects the needle in the
same direction. In this case the instrument is no longer differential in
action. If, when this condition obtains, the magnetic needle be suspended
at the exact center of the line which joins the centers of the coils, the
advantage is gained by obtaining a field of more nearly uniform intensity
around the needle. When the needle is suspended by a silk fibre, a final
and most delicate adjustment can be obtained by raising or lowering one
of the levelling screws slightly, so as to tilt the needle nearer to or
farther from one of the coils.]
The Differential Galvanometer.--This is a form of galvanometer in which
a magnetic needle is suspended between two coils of equal resistance so
wound as to tend to deflect the needle in opposite directions. The needle
of a differential galvanometer shows no deflection when two equal currents
are sent through the coils in opposite directions, since under these
conditions, each coil neutralizes the other's effects. Such instruments
may be used in comparing resistances, although the _Wheatstone bridge_,
in most cases, affords a preferable method.
Ques. What is the special use of the differential galvanometer?
Ans. It is used for comparing two currents.
Ques. What is the method of comparing currents?
Ans. If two equal currents be sent in opposite directions through the
coils of the galvanometer, the needle will not move; if the currents be
unequal, the needle will be deflected by the stronger of them with an
intensity corresponding to the difference of the strengths of the two
currents.
Ques. How are the coils adjusted?
Ans. This is done by coupling them in series in such a way that they tend
to turn the needle in opposite directions, and when a current is passing
through them, they are moved nearer to the needle or farther from it until
the needle stands at zero with any current.
If the coils be not movable, a turn or more can be unwound from the
coil giving the greatest magnetic effect until a balance is obtained,
the wire so unwound can then be coiled in the base of the instrument.
Ballistic Galvanometer.--This type of galvanometer is designed to measure
the strength of momentary currents, such for instance, as the discharge
of a condenser. In construction the magnetic system is given considerable
weight, and arranged to give the least possible _damping effect_.
The term "damping effect" means the offering of a retarding force to
control swinging vibrations, such as the movements of a galvanometer
needle, and to bring them quickly to rest.
If a momentary current be passed through a ballistic galvanometer, the
impulse given to the needle does not cause appreciable movement to the
magnetic system until the current ceases, owing to the inertia of the
heavy moving parts, the result being a slow swing of the needle.
[Illustration: Fig. 526.--Queen dead beat and ballistic reflecting
galvanometer. As illustrated, the coils are easily removable and enclose a
heavy block of copper fixed in a central fork. In a cylindrical hole bored
in this block hangs the bell magnet which with its mirror is suspended
by a long cocoon fibre, and the eddy currents induced in the copper bring
the system quickly to rest after a deflection. By lifting the copper block
out of the frame the instrument is made ballistic. The instrument is made
with coils of any desired resistance up to 1,000 ohms.]
Ques. What name is given to the swing of a ballistic galvanometer needle?
Ans. It is called the _kick_.
Ques. How is the current measured?
Ans. As the needle swings slowly around it adds up, as it were, the
varying impulses received during the passage of the momentary current, and
_the quantity of electricity that has passed is proportional to the sine
of half the angle of the first swing or kick_.
If a reflecting method be used with a straight scale, the observed
deflection depends upon the tangent of twice the angle of movement of
the needle. For small deflections, however, the change of flux can be
taken as directly proportional to the observed deflection.
[Illustration: Fig. 527.--Thompson galvanometer with mirror reflecting
system for reading the deflections of a galvanometer needle by the
movements of a spot of light reflected from a mirror attached to the
needle or movable magnetic system.]
Use of Mirrors in Galvanometers.--In order that small currents may be
measured accurately, some means must be provided to easily read a small
deflection of the needle. Accordingly, it is desirable that the pointer
be very long so that a large number of scale divisions may correspond to
small deflections. In construction, since sensitive galvanometers must
be made with the moving parts of little weight, it would not do to use a
long needle, hence a ray of light is used instead, which is reflected on
a distant scale by a small mirror attached to the moving part.
In the Thompson mirror reflecting galvanometer, as shown in fig. 528,
a small vertical slit is cut in the lamp screen below the scale, and
the ray of light from the lamp, passing through the slit, strikes
the mirror which is about three feet distant, and which reflects the
beam back to the scale. It should be noted that the angle between
the original ray of light and the reflected ray is twice the angle
of the deflection of the mirror; the deflections of the ray of light
on the scale, however, are practically proportional to the strength
of currents through the instrument. The mirror arrangement as shown
in fig. 528, requires a darkened room for its operation, but such is
not necessary when a telescope is used as in fig. 529. Here the scale
readings are reflected in the mirror and their value observed by the
telescope without artificial light.
[Illustration: Fig. 528.--Telescope method of reading galvanometer
deflections by reflection of scale reading in mirror. Here two mirrors
are used, but in most cases the telescope is pointed directly toward the
mirror on galvanometer shown in fig. 527, because the two mirror system,
as illustrated in the figure, is used on portable galvanometers since it
is the more compact.]
Damping.--This relates to the checking or reduction of oscillations.
Thus, a galvanometer is said to be damped when so constructed that any
oscillations of the pointer which may be started, rapidly die away.
Galvanometers are frequently provided with damping devices for the purpose
of annulling these oscillations, thus causing the moving part to assume
its final position as quickly as possible.
Sometimes the instrument is fitted with a damping coil, or closed coil so
arranged with respect to the moving system that the oscillations of the
latter give rise to electric currents in the closed coil, whereby energy
is dissipated. Again, air vanes are employed, but anything in the nature
of solid friction cannot be used.
[Illustration: Figs. 529 and 530.--Galvanometer lamp and scale for
individual use. The scale is etched on a ground glass strip 6 centimeters
wide by 60 centimeters long with long centimeter divisions and short
millimeter divisions the entire length, reading both ways from zero in the
center. It is mounted in an adjustable wooden frame. A straight filament
lamp (110 volts) is enclosed in a metal hood japanned black to cut out all
reflected light. This form of filament makes a single brilliant line on
the scale, enabling closer readings than the "spot of light" arrangement.
The lamp hood is adjustable to any desired height on the support rod.]
D'Arsonval Galvanometer.--This instrument has a movable coil in place of a
needle, and its operation depends upon the principle that if a flat coil
of wire be suspended with its axis perpendicular to a strong magnetic
field, it will be deflected whenever a current of electricity passes
through it.
Ques. Describe the construction of a D'Arsonval galvanometer.
Ans. The essential features are shown in figs. 532 and 533. The coil,
which is rectangular in section is wound upon a copper form, and suspended
between a permanent magnet by fine wires to the points A and B. The magnet
has its poles at N and S. It is a soft iron cylinder fixed between the
poles in order to intensify the magnetic field across the air gaps in
which the coil moves.
[Illustration: Fig. 531.--Queen reading telescope. This arrangement is
utilized to measure the deflections of a galvanometer having suspended
mirror moving system. It consists of a reading telescope mounted as
illustrated with a millimeter scale, having a length of 50 centimeters.
In use, the image of the scale is seen in the galvanometer mirror through
the telescope. The eye piece of the telescope has a cross hair which acts
as a reference line so that by noting the particular division on the scale
when the galvanometer is at rest, the amount of deflection can be readily
observed when the galvanometer is deflected. The instrument has all the
necessary adjustments to set it up quickly and for bringing the cross hair
and scale in focus. It is generally placed at a distance of one meter from
the galvanometer mirror.]
Ques. Explain its operation.
Ans. An enlarged horizontal cross section of the galvanometer on line XY
is shown in fig. 533. The current is flowing in the coil as in fig. 532,
up on the left side and down on the right. The position of the coil when
no current is flowing is indicated by _n' s'_. By applying the law of
mutual action between magnetic poles, it is seen that when the current is
applied, the poles developed at _n' s'_ will move into the position _n''
s''_. See fig. 119.
Ques. How is the coil affected by a change in the direction of the current?
Ans. The polarity of the coil is reversed and consequently the direction
of the deflection.
[Illustration: Figs. 532 and 533.--Diagrams showing essential features of
construction and principle of operation of D'Arsonval galvanometer.]
Ques. Upon what does the sensitiveness of the instrument depend?
Ans. Upon the strength of the field of the permanent magnet, the number
of turns in the suspended coil, and the torsion of the wires by which it
is suspended.
Ques. When is this galvanometer called "dead beat"?
Ans. When the construction is such that the moving part comes quickly to
rest without a series of diminishing vibrations.
[Illustration: Figs. 534 to 536.--Queen horizontal magnet D'Arsonval
galvanometer with telescope and scale. It is very sensitive and is used
in many electrical measurements, including commercial testing, such as
measuring insulation of cables, fault location, etc. It is not affected
by surrounding magnetic disturbances, and may, therefore, be used in
proximity to dynamos and switchboards. The instrument has a pair of
binding post terminals, one of which connects to a bottom spiral of the
system and the other forms a junction with the top of the tube holding the
system, forming a complete circuit through the coil. The tube containing
the system may be readily removed from the magnet and another tube having
a different system inserted as is required for various kinds of electrical
measurement. The entire system with its suspension may be inspected by
the removal of a thumb screw. To inspect interior of tube first be sure
that the screw B is turned so that the coil is clamped. Entirely remove
screw C, and, holding the outside tube near the window, press firmly with
the finger on the extreme top of the suspension support. The inside rib,
with complete suspension, will draw from the tube, and the working parts
can be fully inspected. Carefully return same to its original position in
tube, setting tight the screw C. The galvanometer is designed so that the
coil is clamped in position when the galvanometer must be transported.
The insulation of the galvanometer terminals and binding posts is such
as to guard against any possible leakage. As a further protection, each
levelling screw is provided with a hard rubber insulator. This feature
is essential since, in making insulation measurements, the operator
wishes to be assured that the deflection being obtained is the result
of leakage upon the cable or wire being measured and not leakage between
the galvanometer terminals. The galvanometer is provided with an attached
telescope and scale for noting the deflections. The deflections produced
by this galvanometer are proportional to the current. To facilitate
quickly setting up the instrument, two way levels are provided.]
Ques. What causes this?
Ans. The instrument is made dead beat by winding the coil on a copper or
aluminum frame, so that when in operation, currents are induced in the
frame by the motion of the coil in the magnetic field; these currents
oppose the motion of the coil.
Ques. For what service is the D'Arsonval galvanometer adapted?
Ans. It is desirable for general use as it is not much affected by
changes in the magnetic field. It may be made with high enough period and
sensibility to be satisfactory as a ballistic instrument, but for extreme
sensibility an instrument of the astatic type is more generally used.
Galvanometer "Constant" or "Figure of Merit."--In order that a
galvanometer shall be of value as a measuring instrument, the relation
between the current and the deflection produced by it must be known. This
may be obtained experimentally by determining the value of the current
required to produce one scale division. The galvanometer constant then may
be defined as _the resistance through which the galvanometer will give a
deflection of one scale division when the current applied is at a pressure
of one volt_.
Accordingly, the deflection as indicated on the scale must be multiplied
by its constant or figure of merit, in order to obtain the correct
reading. If the scale readings be not directly proportional to the
quantity to be measured, the law of the instrument must also be
considered.
Thus in a tangent galvanometer as previously explained
I = K tan [phi]
where I = current, [phi] the deflection or scale reading, and K the
galvanometer constant.
[Illustration: Fig. 537.--Diagram showing method of connecting
galvanometer shunt. By the use of a shunt the range of measurement of a
galvanometer can be greatly increased.]
[Illustration: Fig. 538.--Diagram of a form of universal shunt box for use
with galvanometers of widely different resistances. The galvanometer, as
indicated at G, is connected across the ends of a series of resistances
AB. The main wires are connected, one to end A of the series and the other
to a travelling point whose position is varied by means of plugs or by a
dial switch.]
Galvanometer Shunts.--The sensitiveness of a galvanometer used for
measuring current may be reduced to any desired extent by connecting a
resistance of known value in parallel with it. Thus, if it be desired
to measure a current greater than can be measured directly by the
galvanometer, a part of the current can be sent through the resistance or
shunt, and the total value of the current calculated.
A galvanometer shunt bears a definite ratio to the resistance of the
galvanometer, being usually adjusted so that only .1, .01, or .001 part
of the current passes through the galvanometer.
The degree in which a shunt increases the range of deflection of a
galvanometer is called its "multiplying power."
[Illustration: Fig. 539.--Ayrton-Mather universal shunt. This shunt may
be used with any galvanometer. The total resistance is 10,000 ohms, with
shunt powers of 1, 5, 10, 50, 100, 500, and 1,000. It is also fitted with
positions in which the galvanometer is shorted and off. The coils are of
constantan wire.]
If .1 of the current flowing, passed through the galvanometer and
.9 through the shunt, then the current in the circuit would be ten
times that through the galvanometer. Accordingly the current in the
galvanometer must be multiplied by the multiplying power of the shunt
to obtain the true value of the current in the circuit.
In order to determine the resistance necessary to be used with a certain
galvanometer, the resistance of the latter _is to be divided by the
multiplying power desired less one_.
EXAMPLE.--What must be the resistance of a shunt for a galvanometer of
2,000 ohms resistance where only one fifth of the current is to pass
through the galvanometer?
The multiplying power less one is
5 - 1 = 4
and the required resistance is
2,000 ÷ 4 = 500 ohms.
When it is essential that the total resistance of the circuit should not
be altered by an alternation of the galvanometer shunt, a compensating
box should be used which automatically inserts a resistance for each shunt
in series with the shunted galvanometer to bring the total resistance up
equal to the unshunted value. Thus the current in the main circuit is not
altered.
CHAPTER XXVII
TESTING AND TESTING APPARATUS
The practical electrician frequently has to make tests of various kinds
which require the rapid and accurate measurement of voltage, current
and resistance. It is therefore essential that he understand the methods
employed in testing and the operation of the instruments used.
Most tests are made with a galvanometer, and the devices, such as
resistances, switches, etc., which are used in connection with the
galvanometer may be obtained put up in a neat and substantial box together
with the galvanometer, the combination being called a "testing set."
Numerous forms of testing set are illustrated in this chapter.
The construction, use, and operation of the various types of galvanometer
have been explained in chapter twenty-six. Ammeters and voltmeters, which
are simply special forms of galvanometer, and which are largely used are
fully described in the preceding chapter.
Pressure Measurement.--An electromotive force has been defined as that
which causes or tends to cause a current; it is analogous to water
pressure; potential difference corresponds to difference of level. The
_total_ electromotive force of a circuit is independent of resistance or
current, and cannot be limited to mean the fall of pressure between any
two points, as for instance the terminals of a battery.
If the pressure of a battery be two volts when measured on open
circuit by a static voltmeter, there will still be two volts on closed
circuit, but there will now be a loss of pressure through the internal
resistance of the battery and the voltage across the terminals will
be less than the _total_ voltage. The static voltmeter, never closing
the circuit, actually measures the total voltage.
[Illustration: Fig. 540.--Clark cell (Kahle's modification of the Rayleigh
H form), the standard for the International volt. The cell has for its
positive electrode, mercury, and for its negative electrode, amalgamated
zinc. The electrolyte consists of a saturated solution of zinc sulphate
and mercurous sulphate. The pressure is 1.434 volts at 15°C., and between
10°C. and 25°C. the pressure decreases .00115 of a volt for each increase
of 1°C. The containing glass vessel consists of two limbs, closed at
bottom and joined above to a common neck fitted with a ground glass
stopper. The diameter of the limbs should be at least 2 cms., and their
length at least 3 cms. The neck should be not less than 1.5 cms. in
diameter. At the bottom of each limb a platinum wire of about .4 mm. in
diameter is sealed through the glass. To set up the cell, place mercury in
one limb, and in the other hot liquid amalgam, containing 90 parts mercury
and 10 parts zinc. The platinum wires at the bottom must be completely
covered by the mercury and the amalgam, respectively. On the mercury,
place a layer 1 cm. thick of the zinc and mercurous sulphate paste.
Both this paste and the zinc amalgam must be covered with a layer of the
neutral zinc sulphate crystals 1 cm. thick. The whole vessel must then be
filled with the saturated zinc sulphate solution, and the stopper inserted
so that it shall just touch it, leaving, however, a small bubble to guard
against breakage when the temperature rises. Before finally inserting the
glass stopper a strong alcoholic solution of shellac is applied to the
upper edge, after which the stopper is pressed firmly in place.]
Ques. What error is introduced in measuring the pressure of a battery with
an ordinary voltmeter?
Ans. Since the measurement is made on _closed circuit_ the reading does
not give the total pressure of the battery.
The error is very slight because the resistance of the voltmeter is
very high and the current so small that the loss of pressure in the
battery can be neglected.
[Illustration: Fig. 541.--Weston Cadmium Cell. It is made in two forms;
one known as the Weston normal cell, in which the solution of cadmium
sulphate is saturated at all temperatures at which the cell may be used.
The other, known as the Weston standard cell, in which the cadmium
sulphate solution is unsaturated at all temperatures above 4°C. The
Weston normal cell, or saturated form is slightly affected by changes
in temperature, but, on account of the fact that it can be accurately
reproduced, it was adopted by the London Conference in 1908, as a
convenient voltage standard. The value of its voltage suggested by the
committee of the London Conference on Electrical Units and Standards,
and adopted by the Bureau of Standards at Washington, Jan. 1st, 1911, is
1.0183 International volts at 20°C. At any other temperature its voltage
is:
E_{t} = E_{20} - 0.0000406(t-20) - 0.00000095(t-20)^{2} + 0.00000001(t-20)^{3}
The Weston standard cell, or unsaturated form is practically unaffected by
changes in temperature and is the form most commonly used for laboratory
work and general testing. The average pressure of this form is 1.0187 Int.
volts.]
Ques. Define the International volt.
Ans. _It is the electromotive force that, steadily applied to a conductor
whose resistance is one International ohm, will produce a current of
one International ampere, and which is represented sufficiently well for
practical use by 1,000/1,434 of the voltage between the poles of the Clark
cell at a temperature of 15° C., when prepared as in fig. 540._
The relation between the units volt, ampere and ohm, are shown
graphically in figs. 542 and 543.
[Illustration: Figs. 542 and 543.--Diagrams showing hydraulic analogy
illustrating the difference between amperes and coulombs. The _rate_
of current flow of one ampere in fig. 543 may be compared to the rate
of discharge of a pump as in fig. 542. Assuming the pump to be of such
size that it discharges a gallon per stroke and is making 60 strokes
per minute, the quantity of water discharged per hour (coulombs in fig.
543) is 1 × 60 × 60 = 3,600 gallons. Following the analogy further (in
fig. 543), the pressure of one volt is required to force the electricity
through the resistance of one ohm between the terminals A and B. In fig.
542, the boiler must furnish steam pressure on the pump piston to overcome
the friction (resistance) offered by the pipe and raise the water from the
lower level A' to the higher level B'. The difference of pressure between
A and B in the electric circuit corresponds to the difference of pressure
between A' and B'. The cell furnishes the energy to move the current by
maintaining a difference of pressure at its terminals C and D; similarly,
the boiler furnishes energy to raise the water by maintaining a difference
of pressure between the steam pipe C and exhaust pipe D'.]
[Illustration: Fig. 543. If the current strength in fig. 543 be one
ampere, the quantity of electricity passing any point in the circuit per
hour is 1 × 60 × 60 = 3,600 coulombs.]
Current Measurement.--It is necessary to adopt some arbitrary standard in
order to compare currents of different strengths. The term _strength of
a current_, or current strength means the _rate of flow_ past any point
in the circuit in a given unit of time. The unit of current, called the
_ampere_, is defined as _the unvarying current which, when passed through
a solution of nitrate of silver in water (15 per cent. by weight of the
nitrate) deposits silver at the rate of .001118 gramme per second_.
[Illustration: Fig. 544.--Queen weight voltameter for determining the
strength of current by the weight of metal deposited in a given time.
The two outside plates form the anode and are joined together and to one
binding post, while the cathode is placed between them and connected to
the other binding post. The cathode thus receives a deposit on both sides.
An adjustable arm serves to lower the plates into the electrolyte. To
calculate the strength of an unknown current which has passed through a
weight voltameter, _divide the gain in weight by the number of seconds
the current flows through the instrument and by the weight deposited by
one ampere in one second_. That is, current strength in amperes = gain in
weight ÷ (time in seconds × .0003286).]
Ques. How much copper or zinc will one ampere deposit in one second?
Ans. .0003286 gramme of copper in a copper voltameter, or .0003386 gramme
of zinc in a zinc voltameter.
Ques. What is the difference between an ampere and a coulomb?
Ans. An ampere is the unit _rate of flow_ of the current, and a coulomb
is the unit _quantity_ of electricity, that is, the ampere is the rate of
current flow that will deposit .0003286 grammes of copper in one second
and a coulomb is the _quantity_ of electricity that passes a given point
in one second when the current strength is one ampere. In other words a
coulomb is one _ampere second_.
[Illustration: Fig. 545.--Gas voltameter for determining the strength of
current by the volume of gas evolved. To use, connect up as shown in the
illustration. Adjust so that the zero position of the burette is about
one-half inch below the level of the top of the U tube. Pour acidulated
water into the mouth of the burette till the water in the U tube is about
one-half inch from the top. With the electrodes inserted through the
corks, _carefully_ place each one in position by giving a slight twist to
the right as the cork enters. The water level in the U tube and burette
should now be the same, or further adjustment must be made to attain this
result. The level in the burette does not necessarily have to correspond
with the zero graduation, but must not be below it. Unclamp the burette
and hold it nearly horizontal. The liquid will not run out if the corks
be tight, so that this is the _air leakage test_. Attach the connectors
and wires from the current source (which should have a pressure of 2 or
more volts) placing a switch in the circuit. When the switch is closed,
bubbles of gas will rise in the U tube from both electrodes, displacing
the water and forcing it up the burette. Hydrogen will be liberated over
the negative electrode, and oxygen over the positive electrode in the
proportion of twice as much hydrogen as oxygen. To calculate the current
strength, _divide the volume of gas liberated by the time in seconds, and
by the volume of gas liberated (in cubic centimeters) by one ampere in one
second and by .1733_; that is: amperes = volume of gas liberated ÷ (time
in seconds × .1733).]
EXAMPLE.--If an arc lamp require a current of 8 amperes, how much
electricity does it consume per hour?
Since one coulomb = one ampere second, the quantity of electricity
consumed per hour is
8 amperes × ( 60 × 60 ) = 28,800 coulombs.
Voltameter.--A voltameter is an electrolytic cell employed to measure
an electric current by the amount of chemical decomposition the current
causes in passing through the cell. There are two classes of voltameter:
1. Weight voltameters;
2. Gas voltameters.
Ques. What is the difference between these two classes of voltameter?
Ans. In one, the current strength is determined by the weight of metal
deposited or weight of water decomposed, and in the other by the volume
of gas liberated.
Fig. 544 shows a weight voltameter and fig. 545 a gas voltameter.
Ques. How should the plates of a weight voltameter be treated before use?
Ans. They must be thoroughly cleaned and polished with sandpaper, the
sand being afterwards removed by placing them in running water. _The
fingers must not be placed on any part of the plate which is to receive
the deposit._
Ques. What form of voltameter has been selected to measure the
International ampere?
Ans. The silver voltameter arranged as here specified:
The cathode on which the silver is to be deposited shall take the form
of a platinum bowl, not less than 10 cms. in diameter, and from 4 to
5 cms. in depth.
The anode shall be a disc or plate of pure silver some 30 sq. cms.
in area, and 2 or 3 cms. in thickness. This shall be supported
horizontally in the liquid near the top of the solution by a silver
rod riveted through its center.
To prevent the disintegrated silver which is formed on the anode
falling upon the cathode, the anode shall be wrapped around with pure
filter paper, secured at the back by suitable folding.
The liquid shall consist of a neutral solution of pure silver nitrate
containing about 15 parts by weight of the nitrate to 85 parts of
water.
Ques. What is the value of the International ampere as measured with the
silver voltameter?
Ans. The International ampere is represented sufficiently well for
practical use by the unvarying current which, when passed through a silver
voltameter (as described above) deposits _silver at the rate of .001118
gramme per second_.
[Illustration: Fig. 546.--Single contact and short circuiting key. This
key is intended especially for use with D'Arsonval galvanometers in zero
deflection methods. The key is connected in circuit with the galvanometer
so that whenever the key is not depressed, the galvanometer is short
circuited, and its oscillations quickly damped out by the currents induced
in its coil. The back end of the spring is held in a slot in a rubber
block attached to the base.]
Ohm's Law and the Ohm.--The various tests here described depend for their
truth upon the definite relation existing between the electric current,
its pressure, and the resistance which the circuit offers to its flow.
This relation was fully investigated by Ohm in 1827. Using the same
conductor, he proved not only that the current varies with the pressure,
but that it varies in direct proportion.
Ohm's law has already been discussed in a previous chapter and the several
ways of expressing it are repeated here for convenience:
volts
1. Amperes = -------;
ohms
2. Volts = amperes × ohms;
volts
3. Ohms = ---------.
amperes
Various values have been assigned, from time to time, to the ohm or unit
of resistance, the unit in use at the present time being known as the
_International ohm_. This was recommended at the meeting of the British
Association in 1892, was adopted by the International Electrical Congress
held in Chicago in 1893, and was legalized for use in the United States
by act of Congress in 1894. The International ohm in graphically defined
in fig. 548. The previous values given to the ohm which were more or less
generally accepted are as follows:
The Siemens' Ohm.--A resistance due to a column of mercury 100 cm. long
and 1 sq. mm. in cross section at 0° C.
B. A. (British Association) Ohm.--A resistance due to a column of mercury
approximately 104.9 cm. long and 1 sq. mm. in cross section at 0° C.
Legal Ohm.--A resistance due to a column of mercury 106 cm. long and
1 sq. mm. in cross section at 0° C. This unit was adopted by the Paris
conference of 1884.
OHM TABLE[A]
| | Inter-| | | |
| Date |national| Legal|B. A. |Siemens'|
| | Ohm| Ohm|Ohm | Ohm|
-------------------------+------+--------+--------+--------+--------|
International Ohm |1893-4| 1.0000| 1.0028| 1.0136| 1.0630|
Legal Ohm | 1884 | .9972| 1.0000| 1.0107| 1.0600|
B. A. Ohm | 1864 | .9866| .9894| 1.0000| 1.0488|
Siemens' Ohm | | .9407| .9434| .9535| 1.0000|
[A] NOTE.--In the above table to reduce, for instance, British Association
ohms to International ohms, multiply by .9866, or divide by 1.0136; to
reduce legal ohms to International ohms, multiply by .9972, or divide by
1.0028, etc.
[Illustration: Fig. 547.--Double contact key. It is of especial value in
connection with a Wheatstone bridge. When used with the latter it forms
a combination battery and galvanometer key. The battery is wired to the
top leaves of the key and the galvanometer to the lower leaves. Hence,
when operated, the battery circuit will be closed before the galvanometer
circuit, as it is desirable to avoid undue disturbance of the needle.]
[Illustration: Fig. 548.--The international ohm. It is defined as the
resistance of 14.452 grammes of mercury in the form of a column of uniform
cross section 106.3 centimeters in length, at a temperature of 0° C. This
is approximately equivalent to a column 106.3 cm. long, having a uniform
cross section of 1 sq. mm. In the figure the international ohm is defined
graphically. The resistance of the external circuit and the standard one
volt cell is assumed to be zero.]
[Illustration: Fig. 549.--Leeds and Northrup one ohm standard resistance
(Reichsanstalt form); adjusted at 20° C. Low resistance standards may be
properly divided into two classes: 1. those which are designed primarily
as resistance standards, and 2. those designed as current carrying
standards. Those of the first mentioned class are often used to measure
currents up to their capacity. The above standard has both pressure and
current terminals. The binding posts for the former are mounted on high
posts so as to be easily accessible when the standard is immersed in
oil. When used as a resistance standard of precision, it should not be
subjected to a current of more than one ampere, and when used as a current
carrying standard of lesser accuracy, a current of 2 or 3 amperes may be
used.]
Practical Standards of Resistance.--The column of mercury as shown in fig.
548, is the recognized standard for resistance, however, in practice, it
is not convenient to compare resistances with such a piece of apparatus,
and therefore secondary standards are made up and standardized with a
great degree of precision. These secondary standards are made of wire.
The material generally used being manganin or platinoid.
[Illustration: Fig. 550.--Direct deflection method of testing
resistances; a useful and simple method which may be used in numerous
tests. Galvanometer readings are taken through the known, and unknown
resistances, and the current being proportional to the deflections, the
value of the unknown resistance is easily calculated.]
Resistance Measurement.--_Resistance is that which offers opposition to
the flow of electricity._ Ohm's law shows that the strength of the current
falls off in proportion as the resistance in the circuit increases. This
gives a basis for measuring resistance.
There are various methods by which an unknown resistance may be measured,
as by the:
1. Direct deflection method;
2. Method of substitution;
3. Fall of potential method;
4. Differential galvanometer method;
5. Drop method;
6. Voltmeter method;
7. Wheatstone bridge method.
Direct Deflection Method.--This method is based on the fact that the
greater the current through a galvanometer the greater the deflection of
the needle; it is a simple method and is capable of extended application.
The apparatus required consists of battery, galvanometer, known
resistance, and double contact key. The connections are made as in fig.
550. The known resistance is put in circuit with the galvanometer and
after noting the deflection, the key is moved so as to cut out the known
resistance and throw into circuit the unknown resistance. The deflection
of the galvanometer is again noted and compared with the first deflection.
[Illustration: Fig. 551.--Charge and discharge key, adapted to condenser
testing where the condenser is to be alternately charged and discharged.
The insulated handle enables the key to be used without insulating the
body.]
[Illustration: Fig. 552.--Pohl commutator. This is equivalent to a two
pole double throw switch. The depressions in the base are filled with
mercury into which the contacts dip in closing the circuit.]
If the deflections be proportional to the current, the unknown resistance
will be as many times the known resistance as the deflection with
the known resistance is greater than the deflection with the unknown
resistance.
Method of Substitution.--This is the simplest method of measuring
resistance. The resistance to be measured is inserted in series with a
galvanometer and some constant source of current, and the galvanometer
deflection noted. A known adjustable resistance is then substituted for
the unknown and adjusted till the same deflection is again obtained. The
value of the adjustable resistance thus obtained is equal to that of the
resistance being tested.
[Illustration: Fig. 553.--Substitution method of testing resistances.
The connections and apparatus are the same as in fig. 550, except that
a resistance box is used in place of the known resistance. In making the
test, first note deflection with unknown resistance in circuit, then press
key so that the current will pass through the resistance box, and adjust
the resistance in the box so that the deflection of the galvanometer is
about the same as with the unknown. Now switch from one circuit to the
other, changing the resistance in the box until equal deflections are
obtained. When this obtains, the resistance in the box is the same as the
resistance being tested.]
Ques. What kind of adjustable resistance is used in making the above test?
Ans. A resistance box.
Ques. Describe a resistance box.
Ans. It consists of a box containing numerous resistance coils with their
ends connected to terminals and provided with plugs so that they may be
thrown into or out of circuit at will, thus varying the resistance in the
circuit.
[Illustration: Fig. 554.--Ordinary resistance box. It contains sets of
standard resistances consisting of coils of insulated wire having low
conductivity and small temperature coefficient. The ends of the coils are
joined to the section of the bar between the plugs. The insertion of a
plug cuts out a coil. In using, care should be taken to put the plugs in
with a slight twist so that there shall be no resistance introduced by
poor contact.]
Fall of Potential Method.--This is a very simple method of measuring
resistances, and one that is convenient for practical work in electrical
stations because it requires only an ammeter, voltmeter, battery and
switch--apparatus to be found in every station. The connections are made
as shown in fig. 555.
In making the test the ammeter and voltmeter readings are taken at
the same time, and the unknown resistance calculated from Ohm's law.
Accordingly, since:
(1) amperes = volts / ohms
solving for the resistance,
(2) ohms = volts / amperes
[Illustration: Fig. 555.--Fall of potential method of testing resistances;
a convenient method for testing at stations, requiring only the usual
instruments to be found at a station. The resistance of the voltmeter must
be very high, otherwise the test must be made as in fig. 556.]
EXAMPLE.--If in fig. 555 the readings show 6 volts and 2 amperes how many
ohms is the resistance being tested?
Substituting in formula (2)
ohms = 6/2 = 3
Ques. Can this test be made with any kind of voltmeter?
Ans. Its resistance must be very high to avoid error. When a voltmeter
having small resistance is used, it should be connected so as to measure
the fall of pressure across both ammeter and unknown resistance as shown
in fig. 556.
[Illustration: Fig. 556.--Fall of potential method of testing resistances;
diagram showing connections for testing with low resistance voltmeter.
The resistance measured with this connection will be the sum of the
resistances of the coil and the ammeter. The resistance of the ammeter is
usually known and can be subtracted from the sum to obtain the required
resistance.]
Differential Galvanometer Method.--This is what is known as a _nil_ or
zero method, that is, a method of making electrical measurements in which
comparison is made between two quantities by reducing one to equality with
the other, the absence of deflection from zero of the instrument scale
showing that the equality has been obtained.
The test is made with a differential galvanometer, and resistance box
connected as in fig. 557. The current then will divide so that part of
it flows through the resistance being tested and around one set of coils
of the galvanometer while the other part will flow through the resistance
box and the other set of coils as indicated. When the resistance box has
been so adjusted that its resistance is the same as the unknown resistance
the current in the two branches will be equal, and the needle of the
galvanometer will show _no deflection_.
[Illustration: Fig. 557.--Differential galvanometer method of testing
resistances. In making the test, the resistance box is adjusted till the
galvanometer needle shows no deflection. When this condition obtains,
the resistance in circuit in the resistance box is equal to the unknown
resistance, hence, a reading of the box gives the value of the unknown
resistance.]
Ques. What name is given to this method of testing?
Ans. It is called a _zero_ method, distinguishing it from _deflection_
methods.
Ques. For what kind of resistance is the method adapted?
Ans. Since it is a nil or zero method, it is better adapted to the
measurement of non-inductive than of inductive resistances.
Ques. What precaution should be taken with inductive resistances?
Ans. The current must be allowed to flow until it becomes steady to
overcome the influence of self-induction.
Ques. What may be said with respect to the differential galvanometer
method?
Ans. With an accurate instrument it is very reliable.
[Illustration: Fig. 558.--Drop method of testing resistances. The
apparatus is connected as shown and readings taken with voltmeter across
known and unknown resistance. The unknown resistance is then easily
calculated.]
Drop Method.--This is a convenient method, and one which may be used for
measuring either high or low resistances with precision. It is used for
many practical measurements, and requires only a voltmeter, battery, known
resistance and a two way switch.
The instruments are connected as in fig. 558, and in making the test,
the voltmeter is switched into circuit across the known resistance and
then across the unknown resistance, readings being taken in each case.
The value of the unknown resistance, is then easily calculated from the
following proportion:
drop across known resistance known resistance
------------------------------ = ------------------
drop across unknown resistance unknown resistance
from which
unknown known resistance × drop across unknown resistance
resistance = ---------------------------------------------------------
drop across known resistance
[Illustration: Fig. 559.--Leeds and Northrup portable galvanometer
(pointer type A). The sensitiveness of this instrument is such that it may
be substituted in numerous cases for the non-portable reflecting type of
galvanometer; as for instance, in the checking of ammeters and voltmeters
to an accuracy of .2% by the potentiometer method, and on almost all
Wheatstone bridge measurements to commercial accuracies. A current of 2
micro-amperes will cause the pointer to move 1 mm. over the scale, that
is, it has a sensibility of 500,000 ohms. The method of suspending the
moving system is such as to practically eliminate initial friction which
is of value in all zero deflecting methods. The suspensions and moving
system are guarded by springs, which together with the solid construction
of the case render the instrument capable of withstanding rough usage.
Overall dimensions are 5-1/4" × 2-5/8" × 3-1/2"; weight about 3 pounds.]
Ques. What may be substituted for the voltmeter?
Ans. A high resistance galvanometer, whose deflections are proportional
to the current, the value of the deflections being substituted in the
formula.
Ques. What precaution should be taken in making the test?
Ans. The current used should not be strong enough to appreciably heat the
resistance, and if the current be not very steady, several readings should
be taken of each measurement and the average values used in the formula.
Ques. How are the most accurate results obtained?
Ans. By selecting the known resistance as near as possible to the supposed
value of the unknown resistance.
[Illustration: Fig. 560.--Voltmeter method of testing resistances.
Knowing the resistance of the voltmeter, turn switch to the left and from
reading calculate resistance corresponding to one division of the scale.
Turn switch to right and multiply reading by resistance required for
deflection of one division. This gives resistance of voltmeter and unknown
resistance; subtracting from this the resistance of voltmeter gives value
of the unknown resistance.]
Voltmeter Method.--This is a direct deflection method and consists in
determining first the resistance that will deflect the needle through
one division of the scale on a given battery current, then with this
as a basis for comparison the voltmeter is connected across the unknown
resistance whose value is easily calculated from the reading.
In making the test, the instruments are connected as in fig. 560. The
current from battery is first passed through the galvanometer by turning
switch as shown.
[Illustration: Fig. 561.--Megohm box or set of standard high resistances.
The box contains five resistances of 200,000 ohms each. The six pillars
are petticoat insulated, the resistances being placed between each pair
of pillars. There is a double contact post on top of each pillar so that
these can be connected together with copper links.]
Assuming that the resistance of the instrument is 8,000 ohms and that
the current deflects the needle through 10 divisions of the scale,
then for a deflection of one division the resistance is
8,000 × 10 = 80,000 ohms.
Accordingly, if, when the switch is moved to the right, connecting the
voltmeter across the unknown resistance, the needle be moved through
6 divisions of the scale, the combined resistance of the voltmeter
and unknown resistance is
80,000 ÷ 6 = 13,333-1/3 ohms,
and subtracting the resistance of the voltmeter, the value of the
unknown resistance is
13,333-1/3 - 8,000 = 5,333-1/3 ohms.
Ques. For what kinds of test is the voltmeter method best adapted?
Ans. For measuring high resistances, as the insulation of wires, etc.
Ques. What may be said with respect to the current used?
Ans. Its voltage should be as high as possible within the limits of the
voltmeter scale.
[Illustration: Fig. 563.--Standard resistance box: 100,000 ohms, in four
units of 10,000, 20,000, 30,000, and 40,000 ohms. An "infinity" plug
separates each coil from the ones adjacent. Segments are elevated from
the hard rubber top by special washers in order to increase insulation.
Binding posts are so arranged as not to be in the way when plugs are used.]
[Illustration: Fig. 562.--Standard high resistance box: 100,000 ohms. It
is mounted in a brass box with a hard rubber top. Connections should be
made to terminals marked 3 and 4. When the flexible cord is on plug 1,
the box is short circuited, but when on plug 2, the resistance of 100,000
ohms is in series. The box is especially suited to rapid cable testing.]
Ques. In testing cable insulation what is desirable with respect to
voltmeter and current?
Ans. A low reading voltmeter should be used in connection with a large
battery.
[Illustration: Fig. 564.--Diagram showing principle of Wheatstone's
bridge. A, B, C, and D, are the four members which constitute the bridge.
The current from the battery divides at P, part traversing DC, and part
traversing BA. The galvanometer connected to M and N will indicate when
the currents are equal in the two branches by giving _no_ deflection.
This is then a _zero_ or _nil method_ of testing. The resistances and keys
required in testing are shown in fig. 565. In the actual instrument, the
members A, B, C, and D are known by the names given in the figure.]
Wheatstone Bridge Method.--For accurate measurements of resistance this
method is almost universally used. The so-called "Wheatstone" bridge was
invented by Christie, and improperly credited to Wheatstone, who simply
applied Christie's invention to the measurement of resistances.
[Illustration: Fig. 565.--Diagram showing arms of Wheatstone bridge,
resistances and method of connecting galvanometer, battery and unknown
resistance.]
The bridge consists of a system of conductors as shown in fig. 564. The
circuit of a constant battery is made to branch at P into two parts, which
re-unite at Q, so that part of the current flows through the point M,
the other part through the point N. The four conductors A, B, C, D, are
spoken of as the _arms_ of the balance or bridge. It is by the proportion
existing between the resistances of these arms that the resistance of
one of them can be calculated when the resistances of the other three
are known. When the current which starts from the battery arrives at P,
the pressure will have fallen to a certain value. The pressure in the
upper branch falls again to M, and continues to fall to Q. The pressure
of the lower branch falls to N, and again falls till it reaches the value
at Q. Now if N be the same proportionate distance along the resistances
between P and Q, as M is along the resistances of the upper line between
P and Q, the pressure will have fallen at N to the same value as it has
fallen to at M; or, in other words, if the ratio of the resistance C to
the resistance D be equal to the ratio between the resistance A and the
resistance B, then M and N will be at equal pressures. To find out if
this condition obtain, a sensitive galvanometer is placed in a branch wire
between M and N which will show _no_ deflection when M and N are at equal
pressure or when the four resistances of the arms "balance" one another
by being in proportion, thus:
(1) A:C = B:D
If, then, the value of A, B, and C be known, D can be calculated. The
proportion (1) is reduced to the following equation before substituting.
D = BC/A
For instance, if A and C be, as in fig. 565, 10 ohms and 100 ohms
respectively, and B be 15 ohms, D will be (15 × 100) ÷ 10 = 150 ohms.
[Illustration: Fig. 566.--Diagram showing usual arrangement of resistances
in arms of Wheatstone's bridge. In practice the bridge is seldom or never
made in the lozenge shape of the diagrams, figs. 564 and 565, these being
given merely for clearness. The resistance box of fig. 554 is, in itself,
a complete "bridge," the appropriate connections being made by screws at
various points. The letters in the above diagram correspond with those in
figs. 564 and 565, and the three figures should be carefully compared.]
As constructed, Wheatstone bridges are provided with some resistance
coils in the arms A and C, as well as with a complete set in the arm
B. The advantage of this arrangement is that by adjusting A and C, the
proportionality between B and D can be determined, and can, in certain
cases, be measured to fractions of an ohm. In fig. 565 resistances of 10,
100, and 1,000 ohms are included in the arms A and C.
[Illustration: Fig. 567.--Standard resistance box and Wheatstone bridge.
This pattern is a modification of the Anthony form of bridge. All the
resistances are wound upon metal spools. The bridge ratio coils are 1, 10,
100, 1,000, 10,000. The rheostat coils are arranged in five rows, of ten
coils each. The ordinary decade plan (explained in fig. 570) is followed.
The coils may be joined in series in multiple, or in any combination of
series and multiple. The coils may thus be checked against each other in
many combinations. For instance, all the ten ohm coils taken in parallel
may be compared with any one ohm coil. The precision of adjustment is said
to be 1/20th of 1% for the coils of the tenth ohm series, and 1/50th of 1%
for the coils of the rheostat. The ratio coils are certified to be like
each other to within 1/100th of 1%. The box is supplied with battery and
galvanometer keys of substantial construction.]
Ques. Describe the method of testing with the bridge.
Ans. Fig. 567 illustrates the general arrangement of resistances to
be found in an ordinary bridge. The connections are made as shown. In
testing, first _depress_ the battery key, then _tap_ the galvanometer key.
This should be repeated adjusting the resistances till no deflection is
obtained. The resistance then in the arm B × (C ÷ A) will give the value
of the unknown resistance.
[Illustration: Fig. 568.--Ratio coils of Wheatstone bridge. Almost every
box intended to serve as a Wheatstone bridge is furnished with a set of
coils which forms the arms of proportion or ratio arms of the bridge.
There is a choice of several different ways of arranging these coils. The
figure shows the simplest arrangement, which is employed in boxes not
intended for the highest accuracy. The required ratio, as for instance
1:100, is obtained by withdrawing a plug from each arm A and B. Ratios
1/1, 1/10, 1/100, 10/100, etc., or 1,000/1, 1,000/10, 1,000/100, 100/100,
etc., are obtainable in this manner. This simple arrangement is open
not only to the objection that the contact resistance of the plugs which
remain in is always included with the resistance unplugged, but also to
all other objections to be urged against the use of many plugs where a few
will do. The method has the limitation that it is not possible to reverse
the arms of the bridge, that is, to transpose the arms A and B.]
Ques. Why should the battery key be depressed before the galvanometer key?
Ans. To avoid the sudden swing of the galvanometer needle, which occurs
on closing circuit in consequence of self-induction.
Ques. How is it known whether too much or too little resistance be
unplugged?
Ans. The galvanometer needle will be deflected to one side for too much
resistance, and to the opposite side for too little resistance.
[Illustration: Fig. 569.--Method of reversing arms of Wheatstone bridge
with reversing blocks. The arrangement shown in the figure is classical,
being that used in the English post office type of Wheatstone bridge. It
is open to the objections which apply to the use of several plugs, one of
which is withdrawn to obtain the desired resistance.]
Ques. What is the meaning of "Inf.," marked on the bridge?
Ans. It stands for "infinity," because the resistance coil at the point
marked infinity is omitted so that adjacent sections of the arm are
disconnected when the plug is taken out.
In fact, the air gap interposed by the removal of the plug by no means
provides an infinitely great resistance, but is usually called such
because it is vastly greater than any of the other resistances of the
bridge.
[Illustration: Fig. 570.]
[Illustration: Figs. 570 and 571.--Diagrams illustrating the decade plan
of combining resistance coils. In this method the coils are connected
in series and the arrangement avoids the disadvantage of the ordinary
Wheatstone bridge in that the latter requires a large number of plugs to
short circuit the resistances not in use, which introduces an element
of uncertainty as to resistance of the plug contacts and the necessity
of adding up the values of all the unplugged resistances in order
to determine the total resistance in circuit. The necessary regular
succession of values in a rheostat built on the decade plan can be
obtained with either nine or ten coils per decade. The chief reason for
using the latter number is found in the facility with which all the coils
of one decade can be compared with one coil of the next higher decade,
thus permitting the coils of a rheostat to be checked among themselves.
Thus, the ten 1 ohm coils can be checked with a 10 ohm, the ten 10's
with a 100, etc. In some sets the ten coils of a decade can be connected
in series or in parallel, and it then becomes an advantage to have ten
coils to a decade, since the coils in one decade in parallel equal one of
the coils of the next lower decade. When these latter advantages are not
required, and especially when dials or sliding switches are used, there is
little or no advantage in using more than nine coils per decade, as shown
in fig. 570. Here all the coils of the set are connected in series so that
the circuit is never open. Thus it is a slight advantage to have permanent
connections _a_, _b_, and _c_, because all the coils of a decade can be
thrown in circuit by simply pulling out a plug, it not being necessary to
insert it again, as would be the case if the _a_, _b_, and _c_ connections
were not used. Moreover, if any plug make bad contact, its effect is
somewhat lessened by having this bad contact shunted by the remaining
coils of the decade. Again, there are occasions where violent deflections
of a galvanometer are prevented by not having the circuit entirely open
when a plug is taken out.]
The Decade Plan.--In this method of combining resistance coils, there are
9 or 10 one ohm coils for the units place, 9 or 10 ten ohm coils for the
tens place, 9 or 10 one hundred ohm coils for the hundreds place and so
on. Each series of coils of the same value is designated a _decade_. The
connections are usually made as shown in figs. 570 and 571.
It is apparent from the figure that any value in any one decade can
be obtained by inserting between a bar and a block, only one plug;
moreover if several decades be in series, any value up to the limit
of the set can be read off directly from the position of the plugs
without having to add up the unplugged resistance as in the ordinary
arrangement.
[Illustration: Fig. 572.--Two plug arrangement of ratio coils. Each of the
ratio coils has one of its terminals connected to a common center which
corresponds to the block marked C in the figure. The other terminal of
each coil is connected to an individual block, there being one block for
each coil. The bar B on one side of these blocks is joined to the rheostat
and the bar A on the other side to an X post. In the ordinary use of this
set of ratio coils two plugs only are used. One plug is inserted between
the bar A and one of the blocks, 1, 1', 10, 10', etc., of the central row
of blocks. The other plug is inserted between the bar B and any one of
the other blocks of the central row. There are two ratio coils of each
value. To obtain an even ratio as 1,000 to 1,000', one plug is inserted
between the block 1,000 and the bar A, and the other plug between the
1,000 block and bar B, the ratio arms are reversed; that is, the 1,000 ohm
coil is connected to the X post and the 1,000 ohm coil to the end of the
rheostat. When uneven ratios are used, the same ratio can be obtained by
four different combinations. To obtain the ratio one to ten, insert a plug
between A and 1, and another between B and 10, or between A and 1', and B
and 10, and get 1:10, or between A and 1, and B and 10', and get 1:10', or
again, between A and 1' and B and 10', and get 1' to 10'. Other ratios are
obtained in a similar manner. By using more than two plugs and connecting
certain of the coils in parallel combinations, a large number of other
ratios may be obtained. This arrangement offers a convenient method of
measuring the sensibility of a bridge and galvanometer combination that is
frequently applicable. If for instance the one ohm coil is used on either
side after a balance has been obtained the one ohm may be shunted with the
1,000 ohm on the same side. This will make a variation of 1/10 of 1% and
the galvanometer deflection may be noted for this variation. Similarly,
the 1 ohm may be shunted with the 100 for a variation of 1%, or with the
10,000 for a variation of 1/100 of 1%. The ten ohm coil may be shunted
with the 1,000 for a variation of 1% and with the 10,000 for a variation
of 1/10 of 1%. In the arrangement of ratio coils, errors due to plug
contacts are negligible because only two plug contacts enter the circuit,
and with an even ratio, it is only the difference in the resistances of
the two plug contacts that can affect the result. In measuring any of the
ratio coils while in the box it is only necessary to connect to the bar
C and to either the bar A or B and plug in the coils to be measured.]
[Illustration: Fig. 573.]
[Illustration: Figs. 573 and 574.--The Leeds and Northrup decade. The
object of this arrangement is to reduce the number of coils required. In
fig. 573, the 1, 3', 3 and 2 are connected in series. Let the terminals
of the 1 ohm and 2 ohm coils be numbered (1), (2), (3), (4) and (5) (fig.
573). The current enters at point (1) and leaves the coils at the point
(5), traversing 1, 3', 3, 2 = 9 ohms in all. If this series be multiplied
by any factor _n_, then _n_ (1 + 3' + 3 + 2) = _n_ 9 ohms. It will be
seen that if the points (1) and (5) be connected, all the coils are
short circuited, and the current will traverse zero resistance. If the
points (2) and (5) be connected, the 3', 3 and 2 ohm coils will be short
circuited and the current will traverse 1 ohm. By extending the process so
as to connect two and only two points at a time it is possible to obtain
the regular succession of values n (0, 1, 2, 3, 4, 5, 6, 7, 8, 9), the
last being obtained when no points are connected. Fig. 574 shows Leeds and
Northrup's method of connecting these points two at a time with the use of
a single plug. The circles in the diagram represent two rows of ten brass
blocks each. To the first two blocks at the top of the rows, the points
(5) and (1), fig. 573, are connected; to the second two, the points (2)
and (5) are connected, etc., no points being connected to the last pair
of blocks. Hence, if a plug be inserted between blocks 1 and 5, fig. 575,
the points (1) and (5) of diagram fig. 573 are connected, giving the value
of 0, if between the blocks 2 and 5 the points (2) and (5) are connected,
giving the value 1, and so on. The value 9 is obtainable when the plug is
in the last pair of blocks, which have no connections. Fig. 572 shows a
top view of the blocks of a simple decade constructed upon this plan.]
Ques. What other advantages are gained with the decade arrangement?
Ans. The single plug used with each decade is never out of use, being
either in the zero position or set on some value, and is therefore not
easily lost by being laid aside. The use of only one plug in a decade
makes it easy to ascertain that the plug is making good contact as only
one block in a row is plugged at a time, the other blocks are not kept
under a strain by having plugs forced tightly between them.
This strain on the blocks, which always exists in those sets in which
a resistance is thrown in by removing a plug, tends to separate or
loosen them and often to warp the hard rubber upon which they are
mounted. Another advantage of the decade plan is that it permits
obtaining a succession of values by means of sliding contacts or dial
switches, a method which is becoming deservedly more appreciated.
[Illustration: Fig. 575.--Leeds and Northrup dial Wheatstone bridge.
Rotating switches are used instead of plugs, which permits quicker
adjustment of the resistances, adapting it to rapid working. The ratio
coils are arranged as in fig. 568. There are four dials which form the
rheostat. The units dial contains 9 one ohm coils; the tens dial, 9 ten
ohm coils; the hundreds dial, 9 one hundred ohm coils, and the thousands
dial 9 one thousand ohm coils. The values of the ratio coils are 1, 1,
10, 10, 100, 100, 1,000, 1,000, 10,000, 10,000.]
Ques. What is the difference between "plug out" and "plug in" types of
resistance box?
Ans. In the plug out type, resistance is put in the circuit by removing
plugs, as in fig. 565; in the plug in type, resistance is put in the
circuit by inserting plugs as in figs. 570 and 571.
[Illustration: Fig. 576.--Queen Acme portable testing set. It consists
of a Wheatstone bridge, with reversible arms, battery of four dry cells,
D'Arsonval galvanometer, battery and galvanometer keys. There are sixteen
resistance coils, having a combined resistance of 11,110 ohms. Each
bridge arm is provided with three coils of 1, 10, 100 ohms, and 10, 100,
1,000 ohms respectively. The commutator admits of a ratio of 1 to 1,000
on either bridge arm, giving the set a theoretical range from .001 of an
ohm to 11,110,000 ohms. For resistances above 1,000,000 ohms, the normal
battery power must be increased. The contact keys are located as shown.
The battery key has single contact, but the galvanometer key has double
contact; depressing it closes the galvanometer circuit, and releasing it
short circuits the galvanometer, bringing the latter quickly to rest.]
Testing Sets.--For convenience in testing, a combination of the
instruments used is put up in a neat and substantial case, and known
as a testing set. There are innumerable forms of testing set, a few of
which are shown in the accompanying illustrations. The usual combination
is a Wheatstone bridge, galvanometer, battery and necessary keys and
connections.
[Illustration: Fig. 577.--Connections and circuits of Queen acme portable
testing set. There are three rows of blocks, LL', MM', NN'. LL is
connected to NN' by means of a heavy copper bar, joining L' and N'. LL'
and NN' constitute the rheostat, from which any resistance from 1 ohm
to 11,110 ohms may be obtained by removing the proper plugs. The block
N of the rheostat is connected to the lower line post D. The upper line
post C is connected to the block X of the commutator. The block C has no
other permanent connection, except key G. The block R of the commutator
is connected to the block L of the rheostat, and has no other connection,
excepting by plugs. Each half of MM' constitutes a bridge arm, designated
A and B respectively. Beginning at the lower line post D, the connections
form a continuous circuit through the rheostat, thence through the bridge
arm B, thence through the bridge arm A, thence to the upper line post
C. The commutator serves merely to reverse the bridge arms A and B. The
battery terminals are connected as shown: the positive terminal directly
to the common junction of the two bridge arms, and the negative terminal
through the battery key to the rheostat. The positive terminal of the
galvanometer is connected through the galvanometer key with the block X,
and the negative terminal with the block R of the commutator or what is
equivalent, with the block L of the rheostat. The commutator blocks A, B,
R and X, are connected by plugs as shown. When the commutator plugs are
in the position PQ, the bridge arm B is connected to the rheostat and the
bridge arm A is connected to the line, the ratio between the bridge arms
ratio being A ÷ B = X ÷ R but when the plugs are in the position ST, the
bridge arms are reversed in position A, being connected with the rheostat
and B, with the line, and the bridge arm ratio becomes A ÷ B = R ÷ X. The
connections of the testing set may be more readily understood from the
simplified diagram fig. 578.]
[Illustration: Fig. 578.--Simplified diagram showing connections of Queen
Acme portable testing set.]
Ques. Describe the operation of the Queen Acme testing set figs. 576 and
577, in measuring resistance.
Ans. Connect the terminals of the resistance to be measured to the line
posts C and D. Place the battery connections on the two upper tips 0 and
1, thus throwing one end of the battery into circuit, which is sufficient
until an approximate balance is obtained. Employ the 100 ohm coil in each
bridge arm, and place the commutator plugs in the position PQ, or in the
position ST. Then remove plugs from the rheostat until the value of total
resistance employed, or nearly as may be guessed is equal to that of the
unknown resistance. Now press the battery key Ba, and holding it down
momentarily, press the galvanometer key Ga. If the galvanometer needle
swing to the right toward the symbol + the resistance employed in the
rheostat is too high and must be reduced. If the needle swing to the left
toward -, the resistance employed is too low and must be increased. By
altering the resistance of the rheostat accordingly, a value will soon be
found, which when varied slightly either way, will reverse the deflection
of the galvanometer needle. Now remove the battery connection from tip 1,
and place it on the tip 4, thus throwing the whole battery into circuit.
Then press the keys again as before, first the battery key, then the
galvanometer key. This will increase the deflection of the galvanometer
needle for the same variation in the rheostat, thus enabling the making
of a more accurate adjustment. The measurement thus made will be the
best result that can be obtained with bridge arms of equal value, but by
selecting more suitable values of the two arms from the following table
of bridge ratios a much higher degree of accuracy may be obtained.
[Illustration: Fig. 579.--Diagram of the Queen dial decade portable
testing set. Its dimensions are 9-1/2" long, 7" wide and 7" deep, and
weighs 11-1/2 pounds. The resistances are arranged upon the dial decade
plan, being placed in circuit by means of a rotating switch contact. The
switches are so constructed that they may be turned in either direction,
thereby permitting them to be turned quickly from the highest resistance
in any dial to the lowest resistance in the same dial. This arrangement
avoids the necessity of turning back through all the remaining resistances
in any particular group of coils and is of value in locating swinging
crosses or conditions of momentary balances. The connections for the
various tests are made by the manipulation of one small knife switch
(W.B.--M.L.) and the switch BA.; these are plainly lettered, thus avoiding
the necessity of referring to a diagram of connections. In construction,
the dial switches are made up of eight laminations of No. 28 B. & S.
phosphor bronze, and the form is such as to prevent wearing grooves on
the top of the contact studs. In this instrument the electrical circuits
are soldered throughout excepting the switch contact whose resistance is
negligible. The resistances are wound with manganin. The battery comprises
six cells sub-divided which are easily replaceable. The galvanometer
is the same as in the Queen acme set, but has the addition of an Ayrton
shunt, which is useful in making insulation measurements. The necessary
keys, binding posts, and switches are provided so as to facilitate the use
of the instrument for the various measurements that can be made with it.]
Table Showing the Best Values of Bridge Arms for Measuring any
Desired Resistance
| | Position of|
| Best Values of| Commutator|
| | Plugs as|
Value of Resistance being measured | | | shown in|
| A = | B = | fig. 582|
--------------------------------------+-------+-------+------------|
Below 1.5 ohms | 1| 1,000| PQ|
Between 1.5 and 11 ohms | 1| 100| PQ|
" 11 and 78 ohms | 10| 100| PQ|
" 78 and 1,100 ohms | 100| 1,000| PQ|
" 1,100 and 6,100 ohms | 100| 100| PQ or ST|
" 6,100 and 110,000 ohms | 1,000| 100| ST|
" 110,000 and 1,110,000 ohms | 1,000| 10| ST|
" 1,110,000 and 11,110,000 ohms | 1,000| 1| ST|
Ques. In testing with the Queen Acme set how should the plugs be placed
in the commutator?
Ans. Always make the arm A the smaller except when the two arms are of
equal value.
Ques. If the resistance being measured is higher than 6,100 ohms, or lower
than 1,100 ohms, how should the commutator plugs be placed?
Ans. If higher than 6,100 ohms, they should be placed in the position ST;
if lower than 1,100 ohms, in position PQ.
When the plugs are placed in the ST position, the unknown resistance
is found by dividing the value of the larger bridge arm by that of the
smaller, and multiplying the total employed resistance in the rheostat
by the quotient. When the plugs are placed in the PQ position, the
employed resistance in the rheostat is divided by the quotient.
[Illustration: Fig. 580.--Queen portable silver chloride testing battery.
The silver chloride cell has the advantage of long life, light weight,
and compactness. The pressure of each cell when new is .8 volt.]
Direct Deflection Method with Queen Acme Set.--To measure for instance,
insulation resistance by direct deflection connect a known high
resistance, say 100,000 ohms between the line post C (fig. 577), and the
positive battery post. Remove all plugs from the commutator, and place all
plugs in the rheostat, as any employed resistance in the rheostat will
be in circuit with the galvanometer and the battery. Place the battery
connection so as to throw only one cell into circuit. Now press the keys
and obtain a deflection of the galvanometer needle. For example: assume
that the needle to be deflected about 8 divisions of the scale. Since
this deflection is due to the current from one cell passing through a
resistance of 100,000 ohms, then 100,000 × 8 = .8 megohms represents
the resistance through which one cell will produce a deflection of
one division on the scale. Hence, .8 megohms is the constant of the
galvanometer.
[Illustration: Fig. 581.--Ohmmeter. It consists essentially of a slide
wire Wheatstone bridge, with the scale divided to read either directly
in ohms, or in per cent. of a fixed resistance value. A galvanometer is
mounted on the containing case of each, and battery and galvanometer keys
are provided. In the direct reading type, the scale is so cut that when
the galvanometer is balanced, the pointer of the instrument indicates the
value of the resistance between the X posts. The scale is calibrated for
any desired range. These ohmmeters being slide wire bridges, the greatest
accuracy is at the center of the scale, hence one should be selected that
will bring the part of the scale likely to be the most used at or near the
center. A convenient type is that in which the scale is cut in per cent.,
100 per cent. being at the center of the scale. Fixed coils of 1, 10, 100,
1,000 and 10,000 ohms are contained in the instrument with a plugging
arrangement allowing any one to be used. When a balance is obtained,
the actual resistance is determined by multiplying the dial reading by
the value of the fixed coil in use. This amounts simply to shifting the
decimal point. For instance, if the 100 ohm coil were being used, and the
pointer were at .875, the resistance would be 87.5 ohms.]
Now, replace the known high resistance (100,000 ohms) by the unknown
resistance (for instance such as a cable) the value of which is to be
determined. Add enough cells to produce as large a deflection of the
needle as possible. Assume that 75 cells give a deflection of 1.5 scale
division. Then, the galvanometer constant multiplied by the number of
cells and the product divided by the deflection will give the insulation
resistance of the cable; or
0.8 megohm × 75 cells = 60.0; and
60.0 ÷ 1.5 = 40 megohms
as the resistance of the cable.
[Illustration: Fig. 582.--Commutator plug setting for comparing
electromotive forces by the fall of potential method with Queen acme set.]
Fall of Potential Method with Queen Acme Set.--To compare electromotive
forces by this method, place the battery connection (fig. 577), so as
to throw into circuit all the cells, taking care not to reverse them by
crossing the battery cords. Plug the commutator as shown in fig. 582, and
remove 1,000 ohms from bridge arm B. Place all plugs in arm A. From the
rheostat unplug 5,000 ohms. Then connect one of the cells being tested,
with its positive terminal to the + battery post and its negative terminal
to the line post C.
When the keys are pressed, the galvanometer needle will swing either to
the right or to the left. If it swing toward +, reduce the resistance
in the rheostat; if it swing toward -, add resistance to the rheostat.
When a value is found wherein a variation of an ohm either way reverses
the deflection, add to this value the resistance unplugged in arm B, and
divide the sum by the resistance in arm B. The result gives the ratio
between the voltages of the testing set battery and cell being tested
respectively. The division is decimal and may be readily accomplished by
merely pointing off as many places as there are ciphers in the resistance
employed from arm B. This operation repeated with any number of different
cells, will give their voltages in terms of the voltage of the testing
set battery, and from these ratios their relative values may be readily
obtained.
[Illustration: Fig. 583.--Diagram of apparatus for measuring low
resistances based on the principle of the Kelvin double bridge. In the
diagram AB represents a heavy piece of resistance metal of uniform cross
section and uniform resistance per unit of length; CD is another piece
of resistance metal of smaller cross section, and the two are joined
together by a heavy copper bar, AC, into which both are silver soldered;
LL are the current terminals and PP are the pressure terminals. The
resistance of AB between the marks 0 and 100 on the scale S is .001 ohm.
From the point 1 on the resistance CD to 0 on AB is also .001 ohm, from 2
to 0 is .002 and so on, and from 9 to 100 is .01 ohm. The slider M moves
along the resistance AB and its position is read on the scale S which is
divided into 100 equal parts and can be read by a vernier to thousandths.
Subdivided in this way the resistance between the tap off points PP may
have any value from .001 to .01 ohms by steps of .000001 ohm.]
If the testing set battery be replaced by a standard cell, the first
measurement gives at once the voltage of the cell tested.
If the voltage of the cell or battery being tested exceed that of the
testing set battery, reverse the position of the two batteries, and the
subsequent operations, as outlined above, will give the desired results.
How to check a Voltmeter with the Queen Acme Set.--In using a set as
in fig. 576, first remove about 10,000 ohms from the rheostat, plug the
commutator as shown in fig. 582, remove 100 ohms from the arm B, of the
bridge, and connect a standard cell with the positive terminal to the +
battery post and the negative terminal to the line post C. Then, connect
the circuit to the battery posts of the testing set the positive lead to
the + post and the negative lead to the - post. Now, press both keys and
note the direction of the deflection of the galvanometer needle. If it
move toward +, the rheostat resistance is too high; if toward -, too low.
[Illustration: Fig. 584.--Kelvin bridge. This includes a low resistance
standard of .1 ohm variable by steps of .00001 ohm, a set of ratio coils,
and a holder for rods or wires to be measured, with a scale to measure
their length. It is also provided with heavy flexibles to be used in
measuring the resistances of irregularly shaped pieces. The connections
are clearly shown in the diagram. The range of measurements of this bridge
is: 1 ohm to .1 ohm by steps of .001 ohm readily estimated to .0001; .1
to .01 ohm by steps of .0001 ohm readily estimated to .00001; .01 ohm to
.001 ohm by steps of .00001 ohm, readily estimated to .000001; .001 ohm
down by steps of .00001 ohm, readily estimated to .000001 ohm.]
Change the rheostat resistance accordingly until the balance attained is
such that a very slight variation of the rheostat resistance one way or
the other will reverse the galvanometer deflection. To find the pressure
on the circuit, add 100 to rheostat resistance and point off two places.
Multiply this value by the voltage and the product will be the desired
voltage.
If the voltage of the standard cell be exactly one volt, the total
employed resistance represents the voltage on the circuit.
[Illustration: Fig. 585.--Queen slide wire bridge. It consists of a
portable slide wire, Wheatstone bridge arranged to read directly in ohms
in addition to its use for locating crosses and grounds. It is complete
with battery, galvanometer and telephone receiver. The bridge is balanced
by moving the hand stylus until the galvanometer shows no deflection or
until there is no sound in the telephone receiver. In order to provide a
wide range of measurement and maximum accuracy, ratio coils or multipliers
having values of 1, 10, 100, 1,000 and 10,000 are provided. The scale of
the instrument is arranged in two parts, one of which indicates ohms and
the other is divided into uniform divisions for use when locating crosses
and grounds by the Murray and Varley loop methods. A small induction
coil is included so as to furnish an alternating current when using the
telephone receiver.]
For instance, in making a measurement on a 110 volt circuit, assume
that the employing of 7,840 ohms rheostat resistance produces balance,
and that increasing or decreasing this resistance by two ohms,
reverses the galvanometer deflection. This indication that the setting
7,840 is uncertain, about 1/40 of 1 per cent. Since the rheostat coils
are adjusted to an accuracy of only 1/5 of 1 per cent., that will be
about the accuracy of the measurement.
If the pressure of the standard cell be 1.018 volts, then 7,840 + 100
= 7,940. Pointing off two places, gives 79.40, which multiplied by
1.018 gives 80.82 for the voltage on the circuit.
To Measure Internal Resistance of Cell with Queen Acme Set.--First compare
its voltage on open circuit with the pressure of the testing set battery.
Then, shunt the cell with a known resistance, about 100 ohms, and again
measure its terminal voltage. The difference between the two values thus
obtained, divided by the value of the shunt resistance, will give the
value of the current. To find the internal resistance, multiply the value
of the shunt resistance by the ratio between the first and second measured
values.
[Illustration: Fig. 586.--Evershed portable ohmmeter set. This testing set
consists of a direct reading ohmmeter which indicates by direct reading
the value of the resistance being tested, also a portable hand dynamo
which provides at any required pressure the current necessary to make the
test. It is adapted to the needs of supply stations, wiring contractors
and dynamo builders. It is also useful in testing the insulation of
underground and aerial cables, and is designed so that it can be used by
ordinary workmen who are not experienced in handling delicate instruments
and who, by its use, are able to obtain accurate results. The dynamo is
wound for 100, 200, 500, or 1,000 volts, and is fitted with spring drum
inside the case on which is coiled a twin flexible cord provided with a
connector adapted for clamping under the ohmmeter terminals.]
For instance, assume that the open circuit voltage of the cell being
tested as compared with the voltage of the testing set battery is .212
of the latter, and that when it is shunted with a resistance of 1,000
ohms, its terminal voltage is .179. Then, the total resistance is to
the 1,000 ohms shunt resistance as .212 is to .179 or (.212/.179) ×
1,000 = 1,184, from which deducting the 1,000 ohms shunt resistance,
gives 184 ohms as the internal resistance of the cell.
[Illustration: Fig. 587.--Leeds and Northrup fault finder. A lineman's
instrument for the location of faults, crosses, grounds, and opens in
telephone and telegraph circuits, and for the measurement of conductor
and insulation resistance.]
[Illustration: Fig. 588.--Diagram showing arrangement and connections
of Leeds and Northrup fault finder. It is used to measure conductor
resistance, fault resistance, to locate faults by four different tests,
and when used with a buzzer and telephone, to locate opens. The essential
feature of the instrument is the uniform resistance AB, which lies in a
circle and which has a value of about 100 ohms. By a special construction,
it is so arranged that the contact can be made at any point along it, and
it is therefore equivalent to a very high resistance slide wire. It has
a moving contact C and a uniform scale of 1,000 divisions. In series with
this, there are the two resistances E and R which may be short circuited
by the switches U and V. E has exactly the same resistance as the wire AB.
R has a resistance of 100 ohms, and is the fixed resistance of the bridge
arrangement for resistance measurements. The resistances of 1,000 ohms
and 9,000 ohms connected to the battery post are to protect the battery
and the apparatus from excessive current. The 9,000 ohms may be short
circuited by the switch W.]
Ammeter Test with Queen Acme Set.--Connect a low resistance in series with
the ammeter and run leads from it to the testing set, the positive lead to
the + battery post and the negative lead to the line post C (fig. 577).
Insert a standard cell between the battery posts, with positive terminal to
+ battery post, and negative terminal to - battery post. Plug commutator
as shown in fig. 582. Remove 10,000 ohms from rheostat, and 100 ohms from
bridge arm B. Determine a balance in the usual way by changing the value
of the resistance in the rheostat. This operation will balance the
difference of pressure at the terminals of the shunt resistance against
the standard cell, and its value is equal to
(1.40 × 100) / (R + 100) = 140 / (R + 100)
To determine the current flowing, divide the value of the difference of
pressure thus obtained by the value of the shunt resistance.
[Illustration: Fig. 589.--Resistance measurement with Leeds and Northrup
fault finder. The diagram shows the proper connections and switch settings
for measuring conductor resistance. As in the ordinary slide wire bridge,
the resistance X between the two posts 1 and 2 is obtained from the
formula X = A ÷ (1,000 - A) × R. To avoid the necessity of solving in
each case the fraction A ÷ (1,000 - A), a table is furnished with the
instrument, giving the value of this fraction for each value of A. _The
resistance is accordingly determined in each case by simply setting the
contact C for a balance and reading from the table the resistance opposite
the number corresponding to the scale reading and multiplying by 100,
the value of R._ To use an outside battery, remove the inside battery and
connect the outside battery between the posts Gr and Ba. The pressure of
this battery should not exceed 110 volts. _If it exceed 25 volts, open
switch W._
EXAMPLE--With an unknown resistance connected between the posts 1 and 2,
the galvanometer showed a balance for a dial reading of 387. The number
opposite 387 in the table is .6313; hence, X = .6313 × 100 = 63.13 ohms.]
[Illustration: Fig. 590.--Diagram of the Queen standard potentiometer. The
circuit arrangement is a method of sub-dividing the main potentiometer
wire, MNOPQ, so as to provide for very accurate reading. The secondary
voltage, or that used to supply current to the main potentiometer circuit,
is adjusted by regulating rheostats, "Fast," "Medium," and "Slow" so that
the current flow is exactly .0001 ampere. It is noted that this instrument
requires a very small current for its operation. The instrument is
direct reading for voltage measurements, not exceeding 1.4+. In order to
determine if the current flow through the potentiometer be exactly .0001
ampere, the terminals of the standard cell binding posts are connected
in circuit so that the drop over points between which they are connected
are exactly equal to the voltage of the standard cell used. Binding posts
are provided for connection with various standard cells. The unknown
voltage to be measured is placed in opposition to the current flow in the
potentiometer circuit by connecting to the binding post "XEMF." Observe
that polarity is connected as required. The galvanometer with its shunt
is placed in the standard cell circuit, or X circuit, by means of a
double pole, double throw switch. The switch at T provides for standard
cells of different values and the setting at U allows for temperature
correction. The range of the instrument in volts can be increased by means
of multipliers or volt boxes.]
[Illustration: Fig. 591.]
[Illustration: Fig. 592.]
[Illustration: Fig. 593.]
[Illustration: Figs. 591 to 594.--Diagrams illustrating loop testing. To
properly understand the Murray or Varley loop tests, consider a Wheatstone
bridge (fig. 591) the arms of which are equal. In loop testing, the
rheostat is replaced by a length of cable and the unknown resistance also
by a length of cable, as in fig. 592, both being similar in resistance per
foot. If both lengths be the same, their resistances are the same and the
bridge balances. Now shorten one cable and add resistance in series with
it until the bridge again balances as in fig. 593. The added resistance
equals that of the piece cut off. Hence, if the resistance per foot be
known, the length of the shorter piece can be easily calculated. In the
Murray and Varley tests, the battery circuit is by ground connections
instead of by wire. In the Murray loop the arrangement is similar to fig.
592, the battery circuit being completed by ground connection through
fault in defective cable. Fig. 594 shows the general arrangement of the
Varley loop.]
Loop Test.--This is a method of locating a fault in a telegraph or
telephone circuit when there is a good wire running parallel with the
defective one. In the process, the good and bad wires are joined at their
distant ends and one terminal of the battery is connected to a Wheatstone
bridge, while the other terminal is grounded. There are different ways of
making loop tests as by:
1. The Murray loop;
2. The Varley loop;
3. Special loop.
[Illustration: Fig. 595.--The Murray loop test. The apparatus is connected
as in the figure. The rheostat of the bridge is used in place of the
second arm to permit large adjustment. X and Y are the resistances of the
cable between the fault and the points 1 and 2 respectively.]
The Murray Loop.--In this test only one of the two regular bridge arms
is used, the other being replaced by the rheostat giving an arm of large
adjustment.
The connections are shown in fig. 595. In making the test, close key
and note the deflection of the needle due to pressure of chemical
action at fault, if any. This is called the _false zero_.
Now apply the positive or negative pole of the battery by depressing
the battery key, and balance to the false zero previously obtained
by varying the resistance in arms A or B. Then by Wheatstone bridge
formula: RX=AY, and L=X+Y; Y=L-X, whence
X = A/(R+A)
Y = L(R/(B+A))
[Illustration: Fig. 596.--Murray loop method of fault location with Leeds
and Northrup fault finder. Case I where there are two wires having equal
resistance, in one of which there is a fault. Connect and set switches
as shown; join the good wire to post 1 and the faulty wire to post 2.
The resistance of E is equal to that of AB. From the symmetry of the
arrangement, it is evident that, if the fault were exactly at the junction
between the good and bad wires, the contact point C would rest for a
balance at 1,000 on the scale, or at 500 if the fault were half-way along
the bad wire; hence, at whatever point it comes to rest, the reading
divided by 1,000 and multiplied by the length of the bad wire is the
distance from the instrument to the fault.
EXAMPLE--In a pair of equal wires, 5.8 miles long, one is grounded. With
the connections made as above, and the galvanometer balanced for the
dial reading 124, the distance to the fault is (124 × 58) ÷ 1,000 = .7192
miles.]
[Illustration: Fig. 597.--Murray loop method of fault location with Leeds
and Northrup fault finder: Case II, where the good and bad wires are
_unequal_. The figure shows the connections. It is the ordinary Murray
loop and it is evident that the resistance _a_, to the fault will be
obtained from the formula _a_ = (A ÷ 1,000) × r, where r is the resistance
of the loop, and A is the reading of the contact C on its scale. The
distance d, to the fault is obtained from the formula d = Ar ÷ (1,000 ×
M), where M is the resistance per mile of the faulty wire.
EXAMPLE--A wire having a resistance M of 16.46 ohms per mile is grounded.
This wire was looped with a wire of unknown resistance and the total
resistance of the loop r was measured and found to be 54.07 ohms.
Connections were made as in the figure, and the reading A was found to be
332. Substituting these values in the above formula: d = (332 × 54.07) ÷
(1,000 × 16.46) = 1.09 miles.]
Ques. How may the distance from 2 to the fault be determined in knots or
miles.
Ans. Divide Y by resistance per knot or mile.
The Varley Loop.--This is a method of locating a cross or ground in a
telephone or telegraph line or other cable by using a Wheatstone bridge in
a loop formed of a good wire and the faulty wire joined at their distance
ends. One terminal of the battery is grounded and the other connected
to a point on the bridge at the junction of the ratio arms. The rheostat
arm then includes the resistance of the rheostat plus the resistance of
the fault, while the unknown arm includes the resistance of the good wire
plus the resistance of the bad wire beyond the fault. When the bridge is
balanced, the unknown resistances may be readily determined by a simple
equation.
[Illustration: Fig. 598.--The Varley loop test. The diagram shows the
various connections. X and Y are the resistances of the cable between the
fault and the points 1 and 2 respectively. L is the resistance of the good
and bad cable or X + Y.]
In making the Varley loop test, the resistance of looped cable or
conductors is measured, and then connected as in fig. 598. Close the
battery key and adjust R for balance.
When earth current is present, the best results are obtained when the
fault is cleared by the negative pole, and just before it begins to
polarize. If X be the resistance from 2 to the fault, then
X = (L - R) / 2
also, X divided by the resistance of the cable or conductor per knot
or mile gives the distance of fault in knot or miles.
When the resistance of the good wire used to form a loop with the
defective wire, together with that portion of the defective wire from
the joint to the fault is less than the resistance of the defective
wire from the testing station to the fault, the resistance R must be
inserted between point 1 and the good conductor, the defective wire
being connected directly to point. The formula in this case is
X = (L + R) / 2
[Illustration: Figs. 599 and 600.--Varley loop method of fault location
with Leeds and Northrup fault finder. This method may be used as a check
on the Murray methods. Connect the faulty wire to 1, and measure the
resistance of the loop. Then throw switches as shown in the fig. 600.
Let: a = resistance to fault, d = distance to the fault in miles, M =
resistance of the faulty wire per mile, r = resistance of the loop, R =
resistance of the coil R, or 100 ohms, T = A ÷ (1,000 - A) to be read from
the table. From the Wheatstone bridge relation: a = (r - 100T) ÷ (T + 1),
and d = (r - 100T) ÷ (T + 1)M.
EXAMPLE--A wire having a resistance of 16.46 ohms per mile is grounded.
This was looped with a wire of unknown resistance and the resistance
of the loop was found to be 54.07 ohms. Connections were made as in the
figure, and the reading A was found to be 234. From the table T = .3055,
and substituting: d = (54.07 - 30.55) ÷ (1.3055 × 16.46) = 1.094 + miles.]
Special Loop.--This method may be used to advantage where the length
of the cable or faulty wire only is known and where there are two other
wires which may be used to complete the loop. It is not necessary that
the resistance of the faulty wire and the length and resistance of the
other wires be known. Figs. 601 to 604 show the connections and method of
testing.
EXAMPLE.--All the wires in a cable 10,852 ft. long were found to
be grounded so that none of them could be used as good wires. Two
wires were selected out of another cable going to the same place by
a different route and securely joined to one of the grounded wires
at the distant end. This grounded wire and one of the good ones were
connected as shown in figs. 601 and 602 and the reading A was found
to be 307. Connections were then made as shown in figs. 603 and 604
and A was found to be 610. What is the value of d?
According to formula
d = AL/A = (307 × 10,853)/610 = 5,461 ft.
[Illustration: Figs. 601 and 602.--Special loop test with Leeds and
Northrup fault finder. For the first measurement connect the faulty wire
to 2, either of the good wires, as Z, to 1, the post Gr to ground, and
short circuit the coils R and E by closing switches U and V as in the
figures. Balance in the usual way and call the dial reading A. For the
second measurement, connect the post Gr. (disconnected from ground),
to the other good wire y as shown in figs. 603 and 604, and get another
balance; call this reading A'. The distance d, to the fault is determined
from the simple formula d = AL ÷ A' where L is the length of the cable or
faulty wire.]
[Illustration: Figs. 603 and 604.--Special loop test as made with the
Leeds and Northrup fault finder. Diagram showing connections for the
second measurement. The special loop test may be used to advantage where
the length of the cable or faulty wire only is known, and where there are
two other wires which may be used to complete the loop. To use an outside
battery, connect one pole to Ba, and ground the other. The pressure of
this battery must never exceed 110 volts; if it be over 25 volts, see that
switch W is open.]
The Potentiometer.--For the rapid and accurate measurement of voltage,
current, and resistance, the potentiometer can be recommended. Those in
charge of electric light and power companies, and also those who purchase
large amounts of electrical energy are realizing, more and more, the
necessity of having satisfactory primary standards with which to check
their volt-, ampere-, and watt-meters.
When it is realized that an error of one per cent. in a commercial
instrument means an error of one dollar one way or the other in every
one hundred dollars charged, the need of such standardization apparatus
becomes at once apparent.
The potentiometer, it should be noted, relies for its accuracy, only upon
the constancy and accuracy of resistances and upon standard cells.
With the materials now available, and the skill which has been acquired
in their manufacture, both the resistances and the standard cells are
obtainable which are remarkably constant, and both can be readily checked
for accuracy.
Location of Opens.--These measurements are based on the fact that the
capacity of wires in a cable is ordinarily a measurable quantity, which,
in wire of uniform diameter, is proportionate to length. In making these
tests, a fault finder is used together with a buzzer, dry cells to operate
it, small induction coil, and telephone receiver. These instruments are
to be found in any telephone exchange. It is best to locate the buzzer at
some distance from the fault finder in order that it cannot be heard by
the operator.
[Illustration: Fig. 605.--To use galvanometer of Leeds and Northrup fault
finder in series with the battery: Set switches as shown, and connect
between posts Gr. and 2 (see figs. 587 and 588). The galvanometer will
have the maximum sensibility with the pointer at 1,000 and the minimum at
zero.]
[Illustration: Fig. 606.--To measure high resistances, such as the
resistances of faults with Leeds and Northrup fault finder. _First
Method._--Arrange the switches as shown in the figure. Connect posts Gr.
and 2, turn the handle until the galvanometer needle comes to rest at
an even deflection of ten divisions. Call the reading A. Connect in the
unknown resistance between Gr. and 2. Now close the switch W, so that the
figure 1 appears on the top of the block, and again bring the galvanometer
to a deflection of ten divisions and call the reading B. Then X = (10,000
B ÷ A) - 1,000. In case X be a high resistance, it will be found that
the galvanometer will not deflect ten divisions for any position of the
pointer. In such case, choose a number of divisions which is a factor of
ten, such as 5, 2, or 1, and multiply (10,000 B ÷ A) by ten divided by
the number chosen, as 10/5, 10/2, 10/1. For example, for a deflection
of two divisions: X = (10/2)(10,000 B ÷ A) - 1,000. The satisfactory
range of the set for high resistance measurement may be increased by
using an outside battery of higher voltage. With the contained battery,
satisfactory measurements can be made up to 1 or 2 megohms. When outside
battery is used, connect one terminal to the post Ba, and the other to 2
for the reading A. Connect the battery and unknown resistance in series
between these posts for the reading B. When an outside pressure of 25
volts or over is used, the switch W should not be closed unless there be
a resistance in series with the battery of 10,000 ohms or over. _Second
Method._--For use as a voltmeter to measure high resistances. (More
convenient but not quite as accurate as first method.) Set the switches to
RV, M and 10. Turn the knurled nut on the galvanometer so as to set the
needle to the extreme right hand side of the scale. Connect the posts 2
and Gr. with a short piece of wire. Turn the rotating pointer on the scale
until the galvanometer needle moves over about 20 scale divisions when
the battery key is closed. Remove the connection between 2 and Gr. as the
voltmeter terminals. This makes a simple way of testing for various kinds
and amounts of trouble. On a wet cable a deflection of 10 to 15 divisions
indicates heavy enough trouble to locate with the fault finder. With a
little care, trouble showing only 5 or 6 divisions can be located.]
Before attempting locations for opens it is well to make the following
measurements:
1. The insulation of the broken wire and the insulation of the good wire
with which it is to be compared.
This may be done as shown in fig. 606. It is best that the insulation
resistance be fairly good, but experiments indicate that good results
can be obtained by the methods which follow, even when the insulation
is as low as 100,000 ohms, and fair results when as low as 50,000 to
100,000 ohms.
[Illustration: Fig. 607.--Diagram of connections in testing for opens with
Leeds and Northrup fault finder. The apparatus required consists of fault
finder, buzzer, dry cell to operate buzzer, small induction coil, and
telephone receiver. Connect the battery to the primary of the induction
coil, one terminal of the secondary to the post Ba, and the other to the
connected wires as shown. Set switches U and V so as to short circuit the
two resistance coils.]
2. The resistance between the two sections of the broken wire should be
measured.
This may be done by joining the broken wire and a good wire at the
distant end of the cable and measuring the resistance of the loop. To
ensure close locations, this resistance should be over 100,000 ohms.
Fair locations can be made when the resistance is much lower and it is
worth while to attempt it even if the resistance be as low as 10,000
ohms. The difficulty of determining the balance point increases as
the resistance decreases.
Ques. Describe the method of locating an open with a fault finder.
Ans. (_Case I_) The broken wire will be one of a pair. Select another pair
in the cable that will have the same capacity per mile and join together
the mate of the broken wire and one wire of the other pair. Make the
connections as shown in fig. 607, then depress the battery key and move
the contact to the point of minimum sound in the telephone. The distance
to the break is equal to LA ÷ (1,000 - A), where L is the length of the
good wire.
EXAMPLE: A cable 1.45 miles long contained a broken wire. It was found
that the insulation resistance of the end of this wire was over 10
megohms, as was that of the good pair selected to test against it. The
resistance between the two pieces of the good wire was also over 10
megohms. Connections were made as in fig. 607, and it was found that
the balance point was 476. Accordingly from the table
A / (1,000 - A) = 0.9084
and
d = 1.45 × .9084 = 1.317 + miles.
[Illustration: Fig. 608.--Diagram of connections in testing with Leeds
and Northrup fault finder for open wire in telegraph and other cables
in which the wires are not grouped in pairs. Connect the broken wire to
1. Select a good wire and join to 2. Connect all other wires and ground
them, by connecting to the cable sheath. Connect the distant end of the
broken wire to the others. Ground the end of the induction coil that is
not connected to the post Ba.]
Location of Opens.--(_Case II_) Open wire in telegraph or other cables in
which the wires are not grouped in pairs. The connections are made as in
fig. 608, and the measurement and calculation exactly as in the preceding
case.
The accuracy of the location of both of the above methods depends on
the good and broken pair, or the good and broken wires having equal
and uniform capacity per unit length. It is not always possible to
select wires that are alike in this respect. In such cases, as for
instance, where there is no good wire in the cable containing the
broken wire, and a good wire has to be selected from another cable,
the method of _Case III_ may be used.
[Illustration: Fig. 609.--Diagram of connections for reading in testing
for opens with Leeds and Northrup fault finder, when broken wire and good
wire are not in the same cable.]
[Illustration: Fig. 610.--Leeds and Northrup potentiometer. It is direct
reading from .000001 volt to 16 volts, and with accessories the range
may be extended to 1600 volts, and currents may be measured up to 3000
amperes. The instrument has fifteen coils of 5 ohms each, which are in
series with an extended wire about 190" long of equal resistance. The
electrical circuits are shown in the diagram fig. 611. It is well for
the user to open up the potentiometer and make himself familiar with
its interior construction, in order to fully understand the operation
of the rheostat and other parts. There are no contact resistances in
the potentiometer circuit proper. The potentiometer has low internal
resistance which gives it the maximum sensibility. Compared with high
resistance potentiometer, this is especially advantageous in measuring
the electromotive force of thermocouples, and the fall of potential
across standard low resistances. As constructed, the last one-tenth volt
is covered by the extended wire and the handle which carries the contact
point on the wire may be manipulated rapidly so that a fluctuating
voltage may be accurately followed. When used with any cadmium cell,
the potentiometer is direct reading. The accuracy of the potentiometer
resistances can be verified with the facilities of the ordinary
laboratory.]
Location of Opens.--_Case III_, in which the broken wire and good wire
are not in the same cable. Connect the good wire and broken wire in the
same way as shown in fig. 607, and set the pointer for a balance. Call the
reading A. Then connect the good wire and the broken wire at the distant
end and set the pointer for a new balance. Call this A'. The connections
for this reading are shown in fig. 609. The distance to the break will be
d = (A A' L) / (1,000(A - A') + A A')
where L is the total length of the broken wire.
[Illustration: Fig. 611.--Diagram showing connections of Leeds and
Northrup potentiometer. The coils in the series AD are each 5 ohms, and
between each two there is a brass block with a reamed hole. A pair of
flexible cords with taper plug terminals to fit these holes is furnished.
These coils can be measured with an ordinary Wheatstone bridge and thus
compared with each other to a high degree of accuracy, even if the bridge
be not accurate. For potentiometer work, the essential point is that
they should be like each other, not that they should be accurately any
particular value. In the same way the resistance of the extended wire
can be compared with the resistance of the coils in AD. Its resistance
should be 1.1 times the value of any coil between A and D. Outside
connection with the extended wire may be made by using the posts marked
BR and -BA. This adjustment for balancing an unknown electromotive force
is accomplished by the manipulation of the two contact points M and M'.
The coils AD are arranged in a circle, a revolving switch moving M. A
checking device enables the operator to set this switch without taking his
eye from the galvanometer. The resistance S is of such value that when
it shunts the wire OB, the total resistance between O and B is 1/10 of
the same unshunted. When the shunt is applied, provided the total current
remain the same, the drop between any two points on AB will be 1/10 of
its previous value. The total current will remain the same provided the
total resistance in the circuit remain the same. This is accomplished
by making the coil K such that it exactly compensates for the reduction
in resistance caused by plugging in the shunt coil S. The low scale is
applied by moving the plug from the position 1 to the position .1. With
this change the potentiometer reads from .16 volt down by indicated
steps of .000005 volt. The reading is very simple. For instance, if M
stand at 1.2 and M' at 1.35 revolutions, the reading is 1.2135 volts.
The resistances of the instrument are wound upon metal spools, and are
therefore able to dissipate a comparatively large amount of energy. This
allows the potentiometer to be used for pressure measurements up to 16
volts without the use of a volt box.]
[Illustration: Fig. 612.--Diagram showing actual connections in the
rheostat of Leeds and Northrup potentiometer. The figure corresponds to
R of fig. 611. The rheostat is mounted in the end of the potentiometer
as shown in fig. 610. Rough adjustment of the potentiometer current is
made by means of the variable resistance R. Fine adjustment is made by
means of the variable resistance R'. It will be noted that the 23 ohm
resistance of this latter rheostat is shunted by a resistance of 6.1 ohms,
making possible a very fine regulation. Further, there is in series with
the moving contact a resistance of 400 ohms, which makes the effect of
variable contact resistance negligible. Only one cell of storage battery
should be used. When this battery is fresh, the plug shown in the figure
at 2R should be inserted at R. This gives the greatest resistance in the
rheostat circuit. As the cell runs down, the plug should be changed to
2R. When both plugs are in, the rheostat slide wires are in series with
the potentiometer circuit.]
EXAMPLE: A pair of wires containing one broken wire was connected with
a good pair in a different cable as shown in fig. 607. The reading A
was found to be 180. The good and bad wires were then joined at the
distant end as in fig. 609, and the reading A was found to be 88. The
total length of the bad wire MN was 1.44 miles. Required, the distance
to the break. Substituting the values in the formula:
d = 180 × 88 × 1.44 / 1,000(180 - 88) + 180 × 88 = .211 + mile.
To Pick Out Faulty Wires in a Cable.--Short circuit the coils E and R with
switches U and V. Set the pointer at 1,000. Connect the post Gr. to ground
or the cable sheath and apply the wires one after another to the binding
post 2. The galvanometer will deflect for a faulty wire.
[Illustration: Fig. 613.--Diagram of the Crompton potentiometer. In this
instrument the resistance consists of fourteen coils, each of 10 ohms,
in series with a straight wire, also 10 ohms resistance, thus forming a
system of fifteen equal steps. Across the whole a pressure of 1.5 volt
is applied from a secondary cell, thus providing .10 volt per step. Any
fraction is then tapped off by means of a radial switch on the resistance
coils and a sliding contact on the wire. The standardization is performed
by adjusting a resistance in series with the whole until the standard cell
employed indicates, by means of the galvanometer G, a balance at the point
which represents its electromotive force on the basis given above.]
Ques. What is a potentiometer?
Ans. An arrangement of carefully standardized resistances for measuring
voltages in comparison with a standard cell. It is used for accurate
measurement of voltages, currents, and resistances.
In place of a series of standardized resistances, a slide wire may be
used as in fig. 614.
Ques. Describe one form of potentiometer.
Ans. As shown in fig. 614, it consists of a fine German silver wire about
3 feet long stretched between the binding posts A, B, which are attached
to a wooden base carrying a scale divided into 1,000 equal parts. There
are three circuits, the terminal A being included in each, one including
the battery, and the other two the galvanometer. A three point switch
connects the galvanometer in series with the standard cell SC, or the cell
to be tested C, the circuits being completed by leads terminating in the
sliding contacts M and S.
[Illustration: Fig. 614.--Diagram of potentiometer showing method of
measuring the voltage of a cell. The potentiometer is simply a high
resistance wire of uniform diameter stretched between two binding posts,
A and B, in such a way that contact can be made at its ends and along
its length. Necessary circuits are plainly shown in the figure; SC, is
a _standard cell_ and C, the cell to be tested. M, and S are sliding
contacts, connecting with the "slide wire."]
Ques. Describe the method of measuring the voltage of a cell with a
potentiometer.
Ans. Fig. 614 shows a method of comparing a pressure with that of a
standard cell and is applicable whether the pressure of the cell to
be tested be greater or less than that of the standard cell. In making
the test the switch F is first closed, then the other switch is moved
to D, and M adjusted till galvanometer shows no deflection; similarly,
the switch is moved to G, and S adjusted till galvanometer shows no
deflection. Then, C:SC = AS:AM. from which C = SC × AS ÷ AM.
EXAMPLE.--Let 1.016 volts be the known voltage of the standard cell
SC, and the scale reading of AS be 657, and of AM, 225 as in the
figure, then
C = (1.016 × 657) / 225 = 2.966 volts
The arrangement may, however, be made direct reading, that is,
the slide wire may have a scale of volts instead of lengths or
resistances, as follows: Suppose the standard cell to have a pressure
of 1.434 volts, the sliding contact M is placed at the reading 1.434,
and the adjustable resistance varied till the galvanometer shows no
current. This means that the pressure between A and M is 1.434, and
consequently the pressures all along the slide can be read off the
scale _in volts_. Hence, when S has been adjusted to balance, the
pressure of C is read off the scale in volts.
[Illustration: Fig. 615.--To measure a pressure greater than 1.6 volts
with Leeds and Northrup potentiometer by using a volt box or multiplier.
To measure high voltages it is necessary to connect the voltage across
high resistance and to measure on the potentiometer a definite fraction
of the total drop. In the figure, AB is a high resistance of which CB is
.1th, DB .01th, and EB .001th of the total resistance. The potentiometer
reading is accordingly multiplied by 10, 100, or 1,000, depending upon
whether the switch M is set on C, D, or E. Resistance boxes for this
purpose are called _volt boxes_, and are constructed to multiply the
potentiometer readings by 10, 100, and 1,000. In using them, it is only
necessary to connect the unknown E.M.F. at the posts so marked, and the
potentiometer to the posts marked P. The potentiometer reading is taken
as above and multiplied by a factor depending upon the position of the
switch M, which factor is indicated upon the box. _It is essential in
making these connections that the polarity be carefully observed._]
How to Use a Potentiometer.--All connections must be made as indicated by
the stamping on the instrument. Particular attention must be given to the
polarity of the standard cell, of the battery, and of the voltage, the
corresponding + and - signs being marked. If used with a wall galvanometer
having a telescope and scale, it will be found convenient to place the
potentiometer so that the telescope is directly over the glass index of
the extended wire, thus permitting the observer to read the galvanometer
deflections and potentiometer settings without changing his position.
Potentiometer Current.--A medium sized storage cell will be found
desirable, producing a steady current. Errors in measurements are
frequently made by using an unsteady current.
Setting for Standard Cell.--Set the standard cell to correspond
with the certified pressure of the standard cell as given in its
certificate. In using the potentiometer shown in fig. 610, place
the plug in hole 1, and see that it is always in this position when
checking against the standard cell. Place the double throw switch at
STD. CELL.
Adjust the regulating rheostat until the galvanometer shows no
deflection. In making the first adjustment use the key marked R_{1};
when a balance is almost attained, use key R_{2}, and for the final
adjustment use key marked R_{0}. This cuts out the resistance in
series with the galvanometer and gives the maximum sensibility.
Measurement of Unknown Pressure.--The potentiometer (fig. 610),
as ordinarily used, gives direct readings for voltages up to and
including 1.6 volts. For pressures higher than 1.6 volts, a volt
box or multiplier should be used. After obtaining the standard cell
balance, as previously described, place the double throw switch in
the position marked E.M.F. The balance for the unknown E.M.F. is
obtained by manipulating the tenths switch and rotating the contact
on the extended potentiometer wire. The final position of the two
contacts in conjunction with the position of the plug at the left of
the instrument indicates the voltage under test.
As directed above, use key R_{1} for rough adjustment, R_{2} for
intermediate adjustment, and key R_{0} for final adjustment.
Plug at 1 gives readings for voltage directly from settings of tenths
switch and extended wire contact.
Plug at .1 shunts the potentiometer circuit so that the voltage
measured is .1 of the reading taken directly from the scale. Hence,
the readings taken from the setting of the tenths switch and the slide
wire contact must be divided by 10.
To Balance Galvanometer for Unknown Voltage.--Place plug in hole 1
(fig. 610) for voltages up to 1.6, and in hole .1 for voltages up
to .16. Rotate the tenths switch until a condition of balance is
obtained exactly or approximately. To secure an exact balance, rotate
the contact on the extended wire. The unknown voltage can now be read
directly from the position of the tenths switch and the extended wire
contact if plug be at 1, or by dividing by 10 if plug be at .1.
EXAMPLE.--A balance was obtained with the tenths switch at 1.3, the
extended wire contact at 176 and the plug at 1. The voltage under
test, therefore, is 1.3176. If the plug at .1 had been used, the same
reading would have indicated .13176.
To ascertain if the current in the potentiometer circuit has altered
during a measurement, it is only necessary to plug in at 1, place
the double throw switch on STD. CELL and close the galvanometer key.
No deflection indicates that the current has not changed. If the
galvanometer deflect, the regulating rheostat must again be adjusted
until the galvanometer shows no deflection.
To Measure Voltages from 1.6 to 16.--Pressures up to 16 volts may
be measured by using a greater voltage across the BA posts (fig.
615). For this purpose a battery of about 20 volts should be used.
Insert the large plug at .1 and throw the switch to STD. CELL, then
balance the galvanometer by means of the regulating rheostat. When the
rheostat has been set to secure a balance, insert the large plug at
1, set the switch on E.M.F. and read the voltage in the usual manner.
Multiply the reading by 10.
[Illustration: Fig. 616.--Measurement of current with potentiometer. This
is done by measuring the drop in volts across a known low resistance.
In the figure S is the standard resistance, and on it are the pressure
terminals pp, and the current terminals CC. The potentiometer is connected
to the shunt through the posts marked P. The resistance between the
points pp is adjusted to an even fraction of an ohm. These resistances
are so chosen that in order to determine the current passing through
the shunt, after having obtained a potentiometer balance it is only
necessary to multiply the potentiometer reading by a simple factor. For
instance, in using a .01 ohm standard. It is only necessary to multiply
the potentiometer reading by 100, which gives the current reading in
amperes; similarly, a .1 ohm requires multiplication by 10, and a .001
ohm by 1,000.]
Care of Potentiometer.--The slide wire, although protected to a great
extent by the hood, in time accumulates dust and dirt with a thin film
of oxide. This will tend to increase the resistance in this part of the
circuit owing to poor contact. This wire should, therefore, be cleaned
occasionally.
To do this, unscrew the stop against which the hood strikes when
turned to read zero; then remove the hood and rub the entire slide
wire vigorously with a soft cloth dipped in vaseline. _Do not use
emery or sand paper as this will destroy the uniformity of the slide
wire._ Clean also the steel contact which rubs on the wire, as this
becomes glazed after much use. When the potentiometer is not in use,
the hood should be screwed all the way down, and the lid put in place
to exclude dust.
If it be used in a chemical factory, laboratory, or any place where
acid fumes are prevalent, this latter precaution is important, because
the fumes may attack the slide wire.
It is also well to keep the contact surfaces of the switch studs clean
and bright by wiping them occasionally with a soft cloth dipped in
vaseline.
[Illustration: _Res. of leads on each end is equal to 10 divisions of
slide wire. The slide wire is divided into 1000 parts--20 for the leads,
or 980 divisions. Calibrated scale on Galvanometer:_
Fig. 617.--Diagram of Leeds and Northrup bridge for locating faults in
power circuits, showing arrangement of the connections including the lead
cables and galvanometer contacts. Make connections as shown. The clamps
must be so fastened at A and C that the contact resistances will be very
small. This contact resistance will figure as an error in the measurement.
If, for instance, the contact resistance were equal to .001 of an ohm,
and the wire were of such a size that .001 of an ohm were equal to the
resistance of 20 feet of the cable, there would be an error of 20 feet
in the location of the fault. For this reason all contact resistances
throughout the loop from A to C must be extremely small. The battery is
to be connected to the posts marked Ba., and the post marked Gr. is to
be grounded. It will very frequently happen that the ground is to the
cable sheath or some other conductor. In this case, the binding post Gr.
should be grounded to this conductor. Sufficient battery should be used
to give a readable deflection on the galvanometer for a small movement of
the contact on the bridge wire. The fault is located by the usual Murray
formula. If, for instance, the galvanometer show no deflection when the
contact is at 300 on the scale, it would indicate that the fault is at a
distance from A equal to .003 of the total length of the loop from A to C.
A testing current of five amperes may be used with this bridge. In cases
of necessity, this current may be increased to eight amperes, but when
this current is used it should not be allowed to pass through the bridge
for a longer time than is necessary. It frequently happens that small
faults which have a very high resistance develop in high pressure cables.
Such faults are likely to break down and result in damage and should be
located. It is usually impossible to locate these faults until they have
been partially carbonized. This must be done by applying a sufficiently
high voltage between the cable and the sheath (or whatever it is grounded
on) to break down the fault. In order to prevent the breaking down process
from resulting in a serious burn out a high resistance must be placed in
the circuit which will prevent an excessive current, or the circuit must
be carefully fused. The former procedure is the better.]
Location of Faults where the Loop is Composed of Cables of Different Cross
Sections.--Faults in loops of this character may be located with the same
degree of accuracy as those in loops of a uniform cross section, provided
the length and cross section of each length of cable are known. An example
will illustrate the method:
In the diagram, fig. 617, assume the length of the cable AE to be
550 yards of 25,000 cir. mil., EF, 500 yards of 40,000 cir. mil., and
FC, 1,050 yards of 30,000 cir. mil. These lengths must be reduced by
calculation to equivalent lengths of one size, and for this purpose it is
best to select the largest size. The results of this calculation are as
follows:
550 yds. of 25,000 cir. mil. = 880 yds. of 40,000 cir. mil.
500 " " 40,000 " " = 500 " " 40,000 " "
1,050 " " 30,000 " " = 1,400 " " 40,000 " "
This makes the total resistance of the loop equivalent to 2,780 yards
of 40,000 cir. mil. If the contact show a balance for a reading of
372.5, this indicates that the fault is at a distance of 372.5/1,000 of
2,780 = 1,035.5 equivalent yards. Of this, 880 are in the stretch A E.
Consequently the fault is:
1,035.5 - 880 = 155.5 yards from E.
[Illustration: Fig. 618.--The Fischer portable cable testing set, designed
for locating crosses, grounds and breaks in cables, also for conductor
and liquid resistance measure. The distinguishing feature of the set is
the _master switch_. By means of this switch, connections can be made for
the various tests by a single movement, thus avoiding the labor and time
which have to be expended in interchanging the connections and memorizing
the rather complicated scheme of connections.]
CHAPTER XXVIII
AMMETERS, VOLTMETERS AND WATTMETERS.
An ammeter or ampere meter is simply a commercial form of galvanometer
so constructed that the deflection of the needle indicates directly
the strength of current _in amperes_. A good ammeter should have a very
low resistance so that very little of the energy of the current will be
absorbed; the needle should be dead beat, and sufficiently sensitive to
respond to minute variations of current.
According to the principle of operation, ammeters and voltmeters are
classified as:
1. Moving iron;
2. Moving coil;
3. Solenoid or plunger;
4. Magnetic vane;
5. Hot wire;
6. Electrostatic;
7. Astatic;
8. Inclined coil;
9. Fixed and movable coil.
Again, they are divided according to their use into two classes:
1. Portable type;
2. Switchboard type.
_Milli-ammeters_ or milli-voltmeters are instruments in which the
scale is graduated to read directly in thousandths of an ampere or
thousandths of a volt respectively.
Ques. Describe the moving iron type instrument.
Ans. The arrangement of the working parts are shown in fig. 620. A soft
iron needle N, is pivoted inside of a coil C, and is held out of line with
the axis of the coil by means of a permanent magnet M, when the instrument
is idle. In this position, a pointer P, which is attached to the needle,
stands at the zero mark of the scale S. If a current be passed through
the coil, magnetic lines of force are set up in its center, which tend to
pull the needle into line with them, and therefore with the axis of the
coil. This pull is resisted by the permanent magnet M, and the amount of
deflection of the needle from the zero position depends upon the strength
of the current or the voltage according as the coil is wound to indicate
amperes or volts.
[Illustration: Fig. 620. Moving iron type instrument. The essential parts
are: N, soft iron needle; C, coil; M, permanent magnet; P, pointer; S,
scale. Current passing through the coil acts on the needle, causing it to
turn against the restraining force due to the influence of the permanent
magnet.]
[Illustration: Fig. 621.--Moving coil type instrument. The essential parts
are: A, spiral spring; C, coil; K, soft iron core; M, permanent magnet;
P, pointer; S, scale. Current passing through the coil causes the moving
system to turn against the restraining force due to the influence of the
permanent magnet.]
Ques. Describe a moving coil instrument.
Ans. This type of instrument is shown in fig. 621. It consists of a moving
coil C, to which is attached the pointer, and which is pivoted between
the poles of a permanent magnet M. The coil moves between these poles
and a fixed soft iron core K, and is held in the normal position by two
spiral springs A, above and below the core. The springs also serve to make
electrical connection with the coil C.
When a current passes through the coil, magnetic lines are set up
in it which are at an angle to those passing from one pole of the
permanent magnet to the other. The lines of force, which formerly
passed from one pole of the magnet to the other by straight lines or
by short curved ones, are "stretched" on account of the field produced
by the current in the coil, and, in trying to shorten themselves, tend
to twist the coil through an angle. This tendency to move is resisted
by the two spiral springs, hence the coil moves until equilibrium is
established between the two opposing forces.
The amount of deflection of the pointer depends, either upon the current
strength, or the voltage according to the winding of the coil.
[Illustration: Fig. 622.--Keystone voltmeter; view showing the moving
element being withdrawn by loosening one screw. These instruments are
constructed on the d'Arsonval system, the moving element being shown in
detail in figs. 623 and 624. The entire system is mounted upon a solid
metal base plate. The permanent field magnet is made of a single piece of
magnet steel, and the pole pieces are of soft steel, permanently secured
to the magnet in order that the distribution of the magnetic flux will
not be changed by removal and replacement of the pole piece. Accordingly
the moving mechanism is mounted separately from the field, so that it
can be readily lifted from the field without removing the pole pieces.
The function of the core is to secure a uniform field. The moving coil
is wound upon a form of aluminum, which serves the purpose of damping
by the generation of eddy currents. The winding of the coil is of fine
copper wire, to which current is conveyed by means of the controlling
springs and which, in the case of a voltmeter, is connected in series with
a resistance, and in the case of an ammeter, across the terminals of a
shunt.]
Ques. How does the winding differ in ammeters and voltmeters?
Ans. An ammeter coil consists of a few turns of heavy wire (when designed
to carry the full current), while a voltmeter coil is wound with many
turns of fine wire. Thus, the ammeter is of low resistance, and the
voltmeter of high resistance.
[Illustration: Fig. 623.--New moving element of Keystone instruments,
weight 1.2 grams.
Fig. 624.--Moving element of Keystone instruments assembled in bearing.
The moving element consists of coil, counterpoise and pointer. The
mechanical connections are made by means of screws and steady pins. In
order to adjust for slight set or subset of spring under long use a zero
adjuster is provided by means of which this set can be connected and the
pointer brought back to zero.]
Ques. Why is a high resistance coil used with a voltmeter?
Ans. As actually constructed, most voltmeters are simply special forms
of ammeter. From Ohm's law, the current through a given circuit equals
the pressure at its terminals divided by its resistance. Hence, if a
high resistance be connected in series with a sensitive ammeter that
will measure very small currents, then the current passing through the
circuit is directly proportional to the voltage at its terminals, and the
instrument may be calibrated to read volts.
[Illustration: Figs. 625 and 626.--Connections for series and shunt
ammeters. When the construction is such that all the current passes
through the instrument, it is connected as in fig. 625, but where the
instrument is designed to take only a fraction of the current, it is
connected across a shunt, as in fig. 626, a definite proportion of the
current passing through the instrument and the remainder through the
shunt.]
Ques. Into what two classes may ammeters be divided?
Ans. They are classed as series or shunt according to the way they are
designed to be connected with the circuit.
Ques. What determines the mode of connecting ammeters?
Ans. When the wire of the ammeter coil is large enough to carry the whole
current, it is connected in the circuit _in series_ as shown in fig. 625.
If, however, the wire be small, the instrument is connected _in parallel_
with a shunt of low resistance, so that it only carries a small part of
the current, as in fig. 626.
For circuits which carry large currents, the shunt connection is
always used, because otherwise the coil of the ammeter would have to
be very heavy and the instrument correspondingly bulky.
Ques. How are shunt ammeters arranged to correctly measure the current?
Ans. The coil is arranged so that a definite proportion of the whole
current passes through it. A large conductor of low resistance is
connected directly between the two terminals or binding posts of the
instrument; the coil is connected as a shunt around a definite part of
this main conductor; then, since the two are connected in parallel and
each branch has a definite resistance, the current divides between the
two branches directly in proportion to their relative conductivities,
or inversely according to their resistances. The coil, therefore, takes
a definite part of the whole current, and the force moving it and its
pointer away from the zero position is directly proportional to the whole
current. Hence, by providing a proper scale, the value of the entire
current will be indicated.
[Illustration: Figs. 627 and 628.--Westinghouse ammeter shunts. These
shunts are used where heavy currents are to be measured. The shunt is
connected in series with the bus bar or circuit to be measured, and its
terminals are connected by means of small leads to the ammeter or other
instrument. These shunts are designed to have approximately 50 millivolts
drop at full rated current. They are intended primarily for Westinghouse
meters, but can be used satisfactorily with any meter requiring 50
millivolts for full scale deflection.]
Ques. How is a voltmeter connected?
Ans. A voltmeter is always connected to the two points, whose difference
of potential is to be measured.
For instance, to measure the voltage between the two sides A and
B of the circuit shown in fig. 629, one terminal of the voltmeter
is connected to wire A, and the other to wire B. If the "drop"
or difference in voltage through a certain length of wire L, of a
circuit, as from A to B in fig. 630 is to be determined, one terminal
of the voltmeter is connected to A and the other to B. In a similar
manner is found the drop through a lamp.
[Illustration: Fig. 629.--Voltmeter connection for measuring the pressure
in an electric circuit. The voltmeter is connected in parallel in the
circuit at the point where the voltage is to be measured.
Fig. 630.--Voltmeter connection for measuring the "drop" or fall in
voltage in a certain length of wire, as for instance, the length between
the points A and B. The voltmeter is shunted between the two points whose
pressure difference is to be measured.]
Ques. What is the difference between a voltmeter and an ammeter?
Ans. A voltmeter measures pressure, while an ammeter measures current. As
actually constructed, most voltmeters are simply special forms of ammeter.
If a high resistance be connected in series with a sensitive ammeter
that will measure very small currents, then the current passing
through the circuit is directly proportional to the pressure or
voltage at its terminals and the instrument may be calibrated to read
volts.
Ques. Explain the term "calibrate."
Ans. To calibrate a measuring instrument is to determine the variations
in its readings by making special measurements, or by comparison with a
_standard_.
[Illustration: Fig. 631.--Weston ammeter; view showing shunt enclosed
within the instrument. Weston instruments are direct reading and dead
beat. Although the scales have practically uniform divisions, it is not
assumed in the calibration that they are uniform, and the scales are not
printed or engraved. The method of calibration consists in laying out each
large division of the scale by comparing the instrument with a standard,
and then inking in the division lines so found. The smaller divisions
between the large ones are then equally spaced and marked by a mechanical
method.]
[Illustration: Fig. 632.--Weston portable voltmeter, inspector's style.
This instrument is provided with a reversing key. Instead of the regular
binding posts, pins are used with which connections are made by means of
contact cups attached to flexible cords. These contact cups are convenient
in making connections, or in changing quickly from one range to the other,
if the instrument have a double scale. Connections for the different
ranges are made in precisely the same way as with the regular double scale
voltmeters. For the upper scale values, the contact pin to the right and
the front contact pin to the left being taken, and for the lower scale
values, the left contact cup is changed to the rear contact pin.]
Ques. Describe a solenoid or plunger ammeter.
Ans. This type consists of a "plunger" or soft iron core arranged to
enter a solenoid. Current being passed through the wire of the solenoid
causes the core to be more or less attracted against a restraining force
of gravity or springs. A pivoted pointer attached to the core indicates
the current value on a graduated dial as shown in fig. 633.
Ques. What are the objections to plunger instruments?
Ans. They are not reliable for small readings, and are readily affected
by magnetic fields.
[Illustration: Fig. 633.--Plunger type instrument. The current to be
measured passes through the solenoid, producing a magnetic effect on the
soft iron plunger which tends to draw it into the coil, and thus cause
the pointer to move over the graduated scale. The distance the rod moves
depends on the value of the restraining force (which may be springs or
gravity), the coil winding, and strength of current. The winding consists
of a few turns of heavy wire for an ammeter, and a large number of turns
of fine wire when constructed as a voltmeter. Since the iron has a certain
amount of residual magnetism, the deflection with smaller following large
currents is more than would be produced by the same current following
a smaller one. The instrument therefore is less reliable than the usual
types.]
Ques. Describe a magnetic vane instrument.
Ans. It consists of a small piece of soft iron or _vane_ mounted on a
shaft that is pivoted a little off the center of a coil as shown in fig.
634. The principle upon which the instrument works is that a piece of
soft iron placed in a magnetic field and free to move will move into
such position as to conduct the maximum number of lines of force. The
current to be measured is passed around the coil producing a magnetic
field through the center of the coil. The magnetic field inside the coil
is strongest near the inner edge, hence, the vane will move against the
restraining force of a spring so that the distance between it and the
inner edge of the coil will be as small as possible. A pointer, attached
to the vane shaft moves over a graduated dial.
[Illustration: Fig. 634.--Magnetic vane instrument. A soft iron vane,
eccentrically pivoted within a coil carrying the current to be measured,
is attracted toward the position where it will conduct the greatest number
of magnetic lines of force against the restraining force of a spring or
equivalent.]
Ques. Describe an inclined coil instrument.
Ans. As shown in fig. 635, a coil carrying the current, is mounted at an
angle to a shaft to which is attached a pointer. A bundle of iron strips
is mounted on the shaft. A spring restrains the shaft and holds the
pointer at the zero position when no current is flowing. When a current
is passed through the coil, the iron tends to take up a position with its
longest sides parallel to the lines of force, which results in the shaft
being rotated and the pointer moved on the dial, the amount of movement
depending upon the strength of the current in the coil.
The coils for large sizes are generally wound with a few turns of flat
insulated copper ribbon. The instruments are adapted to either direct
or alternating currents but are recommended for alternating currents.
[Illustration: Fig. 635.--Thompson inclined coil ammeter. It is
constructed on the magnetic vane principle in which an iron vane is
attracted by the magnetic field due to the coil, so as to turn itself
parallel with the axis of the coil, the latter being inclined with respect
to the axis of the vane. The voltmeter of this type has a similarly placed
stationary coil, but in place of the iron vane, is provided with a moving
coil in series with the other coil. The restraining force in each case
being that due to springs. Figs. 636 and 637 show the actual construction
of inclined coil instruments.]
[Illustration: Figs. 636 and 637.--Thompson inclined coil portable
indicating instruments. Fig. 636, ammeter type P interior; fig. 637,
wattmeter, type P, interior. These instruments, though primarily designed
for use on alternating current circuits, may also be used on direct
current circuits, by making reversed readings and taking the mean as the
true indication. The voltmeters and wattmeters are constructed on the
dynamometer principle and the ammeters, on the magnetic vane principle.
The voltmeters and wattmeters are provided with a contact key which may
be locked in position, enabling the instruments to be left constantly in
circuit. The movements of the pointer are damped by means of an air vane;
there is also a friction damping device operated by a small button to
check excessive oscillations of the pointer. The inclined coil instruments
are so designed that the torque is sufficiently high to insure the pointer
assuming a definite position with each change in current value.]
Ques. What is the principle of the hot wire instrument?
Ans. Its action depends upon the heating of a conductor by the current
flowing through it, causing it to expand and move an index needle or
pointer, the movements of which, by calibration, are made to correspond
to the pressure differences producing the actuating currents.
Ques. What are the characteristics of hot wire instruments?
Ans. Voltmeters of this type are not affected by magnetic fields, and
as their self-induction is small, they can be used on either direct or
alternating currents; but they possess certain serious defects: they
consume more current than the other types; cannot be constructed for small
readings; are liable to burn out on accidental overloads; and are somewhat
vague in the readings near the zero point and are sometimes inaccurate in
the upper part of the scale.
Ques. Describe the construction and operation of the Whitney hot wire
instruments.
Ans. As shown in fig. 638, a wire AX, of non-oxidizable metal, of high
resistance and low temperature coefficient, passes over a pulley B mounted
on the shaft C. The ends of the wire are attached to the plate E at its
ends F and G, the wire being insulated from the plate at G. A spring H
holds the wire in tension and takes up the slack due to the expansion
caused by the heating of the wire when a current passes through it. The
current flows only in the portion of the wire marked A, between the plate
E and the pulley B up to the point K where the connection is shown. When
a current flows through the wire A, the spring takes up the slack, pulls
A around B, and causes B to rotate upon its shaft C. It is clear, that a
pointer attached to C, would indicate on a scale the movement of B and C,
but as this movement is very slight, a magnifying device will be required.
This device consists of a forked rod L, rigidly attached to the shaft
C, and carrying at its lower end a silk fibre fastened to the fork and
passing around a pulley M, to which a pointer N is attached. For direct
current measurements only an electromagnetic system is used.
[Illustration: Fig. 638.--Diagram showing principle and construction of
the Whitney hot wire instruments. The action of instruments of this type
depends on the heating of a wire by the passage of a current causing the
wire to lengthen. This elongation is magnified by suitable mechanism and
transmitted to the pointer of the instrument.]
Ques. What is the principle of electrostatic instruments?
Ans. The action of these instruments depends upon the fact that two
conductors attract one another when any difference of electric pressure
exists between them. If one be delicately suspended so as to be free to
move, it will approach the other.
[Illustration: Fig. 639.--Kelvin electrostatic voltmeter; a form of
instrument designed for measuring high pressures up to 200,000 volts.
The instrument, as illustrated, consists of fixed and movable vanes with
terminals connecting with each. These vanes which act as condensers take
charges proportional to the potential difference between them, resulting
in a certain attraction which tends to rotate the movable disc against the
restraining force of gravity. In the figure _aa_ and _b_ are two fixed
vanes and _c_ a movable vane, carrying a pointer and having a proper weight
at its lower end.]
Ques. Describe the Kelvin electrostatic voltmeter.
Ans. A simple form consists, as shown in fig. 639, of a metal case
containing a pair of highly insulated plates, between which a delicately
mounted paddle shaped needle is free to move. When the needle is connected
to one side of a circuit and the stationary plates to the other side, the
needle is attracted and moves between them as indicated by the pointer.
Adjusting screws at the lower end of the needle allow it to be balanced
so that its center of gravity is somewhat below the center of suspension.
Gravity then is the restraining force.
The range of the instrument may be changed by hanging different
weights upon the needle. By increasing the number of blades the
instrument can be made to measure as low as 30 volts. The form having
two stationary blades and one movable blade is suitable for measuring
from 200 to 20,000 volts. The quadrant electrometer or laboratory form
will measure a fraction of a volt.
[Illustration: Fig. 640.--Thompson astatic instrument without cover.
When current passes through the coils of the moving element, the lines
of force parallel to the shaft produce a torque which tends to turn the
shaft and cause the needle to travel across the scale. This action is,
of course, opposed by the magnetic field at right angles to the shaft
acting on the two pieces of magnetic metal. These astatic instruments have
no controlling springs. The two small silver spirals which conduct the
current to and from the armature are made of untempered silver and exert
no force as springs. The actuating and restraining forces are dependent
upon the same electromagnets. The damping effect in these instruments
is produced by an aluminum disc moving in a magnetic field, and is
proportional to the square of the magnet strength.]
Ques. Explain the construction and principle of the Thompson astatic
instruments.
Ans. The fields of these instruments are electromagnets wound for any
specified voltage and provided with binding posts separate from the
current posts of the instrument. The moving coils are mounted upon an
aluminum disc and are located in a magnetic field which is parallel to
the shaft and astatically arranged. Two small pieces of magnetic metal
are rigidly mounted on the shaft and the astatic components of the
magnetic field, which are perpendicular to the shaft, tend to keep the
pieces of magnetic metal in their initial positions. When current passes
through the coils of the moving element, the lines of force parallel to
the shaft produce a torque which tends to turn the shaft and cause the
needle to travel across the scale. This action is, of course, opposed
by the magnetic field at right angles to the shaft acting on the two
pieces of magnetic metal. There are thus no restraining springs, current
being conveyed to the moving coil by torsionless spirals of silver wire.
Thompson astatic instruments can be provided with polarity indicators, a
red disc showing on the scale card where the poles are reversed.
The effect of external fields is eliminated by the astatic arrangement
of the fields and the moving parts. A field which tends to increase the
torque on one side of the armature diminishes it to a corresponding degree
on the other side. The damping effect in these instruments is produced by
an aluminum disc moving in a magnetic field.
[Illustration: Fig. 641 to 642.--Multipliers for Western standard
portable voltmeters. Multipliers are resistance boxes, the coils in
which are highly insulated, and are adjusted so that the readings of the
instrument may be multiplied by any desired constant. Multipliers are
usually constructed so that the indications of the pointer, multiplied
by 2, 5, 10, 20 or 50, will give the voltage of the circuit. By the use
of multipliers the range of voltmeters may be increased to any practical
limit.]
[Illustration: Fig. 643.--Portable multiplier for portable voltmeter. A
multiplier is used for increasing the readings of voltmeters, and consists
of resistance coils placed in a portable case. A multiplier is connected
in series with the voltmeter and must be adjusted for the instrument with
which it is to be used, because the resistance coil must be a multiple of
the voltmeter resistance. For instance, a multiplier with a value of 10,
used with a 6 volt voltmeter or 521 ohms would measure about 5,215 ohms;
one with a value of 40, would equal about 20,860 ohms. The multiplier
10 would give a total scale value of 60, and the multiplier 40, a total
scale value of 240 volts to the 6 volt instrument. A multiplier is of
considerable value in that it does away with the necessity of having a
number of voltmeters of different ranges. The instrument here illustrated
has a range of 150 volts.]
Ques. What are multipliers?
Ans. These are extra resistance coils which are connected in series with
a voltmeter for increasing its capacity or readings. They are put up in
portable boxes, and must be adjusted for each particular voltmeter as the
resistance of a multiplier coil must be a multiple of the resistance of
the voltmeter itself.
Ques. What is an electro-dynamometer?
Ans. An instrument for measuring amperes, volts, or watts by the reaction
between two coils when the current to be measured is passed through them.
One of the coils is fixed and the other movable.
[Illustration: Figs. 644 to 645.--Western standard portable shunts.
The milli-voltmeters used in connection with these shunts read directly
in amperes. Shunts of different capacities can be adjusted to the same
instrument, and it can, therefore, be used to measure a current of 2,000
amperes with the same degree of accuracy as a current of 1 ampere. In
selecting shunts of different capacities for use in connection with
one instrument it should be considered that the higher ranges must be
even multiples of the lower one in order to suit the same scale on the
instrument.]
Ques. Describe the Siemens' electro-dynamometer.
Ans. The essential parts are shown in fig. 646. The fixed coil A, composed
of a number of turns of wire is fastened to a vertical support, and
surrounded by the movable coil B of a few turns, or often of only one
turn. The movable coil is suspended by a thread and a spiral spring C,
below the dials which are fastened at one end to the movable coil and at
the other end to a milled headed screw D, which can be turned so as to
place the planes of the coil at right angles to each other, and to apply
torsion to the spring to oppose the deflection of the movable coil for
this position when a current is passed through the coils. The ends of the
movable coil dip into two cups of mercury E, E', located one above the
other and along the axis of the coils so as to bring the two in series
when connected to an external circuit. The arrows show the direction of
current through the two coils. An index pointer F is attached to the
movable coil. The upper end of this pointer is bent at a right angle,
so that it swings over the dial between two stop pins G, G', and rests
directly over the zero line when the planes of the coils are at right
angles to each other. A pointer H is attached to the torsion screw D, and
sweeps over the scale of the dial. The spring is the controlling factor
in making the measurement.
[Illustration: Fig. 646.--Diagram of Siemens' electro-dynamometer.
It consists of two coils on a common axis, but set in planes at right
angles to each other in such a way that a torque is produced between the
two coils which measures the product of their currents. This torque is
balanced by twisting a spiral spring through a measured angle of such
degree that the coils shall resume their original relative positions. If
the instrument be used for measuring _current_, the coils are connected in
series, and the reading is then proportional to the square of the current.
If used as a _wattmeter_, one coil carries the main current and the other
a small current, which is proportional to the pressure. The reading is
then proportional to the power in the circuit.
Fig. 647.--Diagram showing connections of Siemens' electro-dynamometer as
arranged to read watts.]
[Illustration: Figs. 648 to 650.--Wright demand indicator. This is a
device for registering the maximum ampere demand of appreciable duration
in any electrical circuit. It may be used on either direct or alternating
current circuits. The essential features and principle are as follows: A
liquid is hermetically sealed in a glass vessel consisting of two bulbs
connected by a "U" tube, and a central tube called the "index" tube,
connected to the upper end of the right hand side of the "U." Around the
left hand or heating bulb, is placed a band of resistance metal, through
which the current to be measured is passed, or a definite shunted portion
of it. The heating effect of the current increases the temperature of the
left hand bulb, causing the air to expand which forces the liquid up the
right hand side of the "U" tube and into the index tube, where it remains
until the indicator is reset. The height of the liquid in the index tube
as shown by the scale, indicates the maximum current which has passed
through the indicator. It is the difference in temperature of the air in
the two bulbs which causes the flow of the liquid. Any change in external
temperature causes equal effect in both bulbs and therefore does not
affect the reading.]
[Illustration: Figs. 651 and 652.--Weston illuminated dial station
voltmeter and ammeter. The voltmeter has two indices, a pointed index for
close readings and an index called the _normal index_, which enables a
slight deviation from the normal voltage to be seen from a long distance.
The "normal index" is inside the case and terminates in a circular disc
of blackened aluminum. The disc is adjusted from the outside of the case
by hand, by means of the knurled knob seen on the front of the case, so
that it is directly below the point of normal voltage. When the indicating
index reaches the point of normal voltage, the disc of the normal index
appears in the center of the circular opening of the indicating index,
a narrow ring of white being visible, encircling the disc of the normal
index. The ammeter depends for its operation upon the fall of potential
between two points of the circuit carrying the main current, and requires
a difference of only about .05 volt to give a full scale deflection.
When a maximum deflection is secured, the current passing through the
instrument is never more than .07 ampere irrespective of the total
capacity of the instrument. A separate shunt is used which is placed
at the back of the switchboard. In many cases, a special shunt can be
dispensed with and a short section of the mains on the switchboard, or
the mains leading from the dynamo, can be used instead. On the basis of
one square inch cross section per 1,000 amperes, a length of about 5 feet
of copper conductor would be required as a shunt, in which case however,
this section of the conductor must be adjusted with precision.]
Ques. Explain the operation of the Siemen's electrodynamometer.
Ans. In fig. 646, when a current is passed through both coils, the
movable coil is deflected against a stop pin, then the screw D is turned
in a direction to oppose the action of the current until the deflection
has been overcome and the coil brought back to its original position.
The angle through which the pointer of the torsion screw was turned is
directly proportional to the square root of the angle of torsion. To
determine the current strength in amperes, the square root of the angle
of torsion is multiplied by a calculated constant furnished by the makers
of this instrument.
[Illustration: Fig. 653.--Thompson watt hour meter (type C-6). This form
is furnished with side connections, the line wires entering at the left
and the load wires at the right. Both sides of the system are carried
through the meter in all sizes up to and including the 50 ampere size. In
meters of larger ampere capacities, a voltage tap is used.]
Ques. How is the electrodynamometer adapted to measure volts or watts?
Ans. When constructed as a voltmeter, both coils are wound with a
large number of turns of fine wire making the instrument sensitive to
small currents. Then by connecting a high resistance in series with the
instrument it can be connected across the terminals of a circuit whose
voltage is to be measured. When constructed as a wattmeter, one coil
is wound so as to carry the main current, and the other made with many
turns of fine wire of high resistance suitable for connecting across the
circuit. With this arrangement, the force between the two coils will be
proportional to the product of amperes by volts, hence, the instrument
will measure watts.
[Illustration: Fig. 654.--Interior view of Thompson watt hour meter (type
C-6). Capacity: 5 to 600 amperes, two wire, and 5 to 300 amperes, three
wire; 100 to 250 volts. The meter is supported by three lugs, the upper
one of which is keyholed, and the lower right hand one slotted. This
permits rapid and accurate levelling as the top screw can be inserted and
the meter hung thereon approximately level. The right hand screw may then
be placed in position and the meter adjusted as may be required before
forcing the screw home.]
Ques. Describe briefly the construction of the Thompson recording
wattmeter.
Ans. It consists of four elements: 1, a motor causing rotation; 2, a
dynamo providing the necessary load or drag; 3, a registering device,
the function of which is to integrate the instantaneous values of the
electrical energy to be measured; and 4, means of regulation for light
and full load.
[Illustration:
HOW TO READ A METER
Fig. 655.--Recording dials of watt hour meter, illustrating method of
reading electric meters. The unit of measurement of electrical energy
is the watt hour. 1,000 watt hours make or equal 1 kilowatt hour. Some
electric meters have 4 dials, the extreme right hand dial of which
registers in kilowatt hours, while others have 5 dials, the extreme right
hand dial of which registers in tenths of kilowatt hours. In making
out bills to customers the extreme right hand dial of a 5 dial meter
is ignored in order that the "state of meter" shown on bills uniformly
requires the addition of 3 ciphers to correctly express the registration
in watt hours. Each division on the right hand dial (ignoring the 5th
dial mentioned) denotes 1,000 watt hours or 1 kilowatt hour; on the next
dial 10 kilowatt hours, on the next dial 100 kilowatt hours and on the
left hand dial 1,000 kilowatt hours. One complete revolution of any dial
causes the hand on the dial immediately to its left to move forward one
division. To take a statement from the meter begin at the left and set
down for each dial the lower figure next to each hand, not necessarily
the figure nearer the hand. In the above example the statement is 1,726
kilowatt hours or 1,726,000 watt hours. Subtract the previous statement
to arrive at registration for a given period. Some meters are subject to
a multiplying constant so stated on their face and the registration of
such meters must be multiplied by the constant as shown, to determine the
actual consumption of electrical energy. The constant is the measure of
the mechanical adjustment in the register of the meter and is the ratio
between the registration of the dial hands and the true consumption. This
adjustment is made always by the manufacturer of the meter and is never
changed in service.]
Ques. What is the action of the motor in the Thompson watt hour meter?
Ans. It rotates at very slow speed, and since there is no iron in its
fields and armature, it has very little reverse voltage. Its armature
current, therefore, is independent of the speed of rotation, and is
constant for any definite voltage applied at its terminals.
[Illustration: Fig. 656.--Interior of Thompson watt hour meter (type
C-6) showing armature, small commutator and gravity brushes. A spherical
armature moving within circular field coils is the construction adopted in
this meter. The armature is wound on a very thin paper shell, stiff enough
to withstand the strain due to winding and subsequent handling. The wire
composing the armature is of the smallest gauge consistent with mechanical
strength. The field coils, as before stated, are circular, and are placed
as near each other as possible, one on either side of the armature, with
the internal diameter just sufficient to give the necessary clearance for
the rotating element. This construction prevents magnetic leakage. Ribbon
wire is employed for the field coils, thus economizing space and further
carrying out the idea of concentration.]
The torque of this motor being proportioned to the product of
its armature and field currents, must vary directly as the energy
passing through its coils. In order then, that the motor shall record
correctly it is necessary only to provide some means for making the
speed proportional to the torque. This is accomplished by applying a
load or drag, the strength of which varies directly as the speed.
Ques. Explain the operation of the Thompson recording wattmeter.
Ans. There being no iron in either field or armature of the motor element,
no considerations of saturation are involved. The torque or pull of the
armature is dependent upon the product of the field and armature strength.
The strength of the field--there being no iron--varies directly with the
current in the field. Thus the strength of the field with 10 amperes
flowing to the load is exactly twice the strength of the field with 5
amperes flowing to the load. The strength of the armature is dependent on
the voltage of the system to which it is connected, the armature element
of the meter being practically a voltmeter. There is, therefore, a torque
or pull varying directly with the strength of the armature multiplied by
the strength of the field, or, in other words, varying directly with the
watt load, and except in so far as influenced by friction, the speed of
rotation varies directly with the torque or pull. The currents generated
in the disc armature consist of eddy currents, which circulate within the
mass of the disc.
Installation of Wattmeters.--The various types of wattmeter differ so
widely either in mechanical details, or operating principles, that it
is customary for manufacturers to furnish detailed instructions for the
installation of their meters. Such instructions should be carefully
followed in all cases, but the following will be found generally
applicable to all types of motor meter:
1. After unpacking the meter, and before opening the case or cover,
clean the latter carefully to remove all adhering particles of dust
and excelsior.
2. The proper location for the meter should be one where there is no
vibration. When this location has been selected, nail or screw upon
the walls, a board somewhat larger than the dimensions of the back of
the meter, and upon this board hang the meter by the top hanger.
3. After hanging the meter, open or remove the case or cover, and
if necessary, put the mechanism in order according to instructions
furnished by the manufacturer.
4. In order to operate satisfactorily, the meter should hang plumb, so
that the spindle of the revolving element will be vertical, and the
horizontal planes through the armature and retarding disc will be
level. Many complaints relative to meters being slow on light loads,
are invariably due to the fact that the meters have been installed
out of plumb[B].
5. In making the circuit connections, be very careful that the
_positive_ lead or wire is placed in the _positive_ binding post of
the meter. This precaution is essential for insuring an accurate and
sensitive measurement on small loads.
6. When a meter of the commutated motor type sparks at the brushes at
starting, it is an indication that the commutator is dusty. Clean it
with a piece of closely woven cotton tape 1/4-inch in width.
7. Meters should never be allowed to remain with their covers off, in
the testing room, station, or any other place. In order to get the
best service, and to give them long life they must be kept clean.
[B] NOTE.--The most practical and accurate method of plumbing a meter is
to level it by means of a small brass weight placed upon the retarding
disc. Place the weight upon the front or back upper surface of the disc,
close to the edge. If the disc and weight rotate toward the right, move
the bottom of the meter in the same direction so as to raise the disc
on the right. When the disc is level, the weight and disc will remain
stationary when the weight is placed on either the front or the back of
the disc. Next, place the weight on the disc close to the edge on either
side. If the disc rotate towards the front, swing the bottom of the meter
away from the wall or board until the disc remains stationary when the
weight is placed upon it on either side. If the disc rotate toward the
back, raise it up on that side by bringing the top of the meter away from
the wall or board. It is possible that the second levelling operation will
alter the position of the disc obtained by the first operation, therefore,
the first should be repeated, and after that the second also, until the
disc remains stationary when the weight is placed at any point upon its
surface. This method of levelling is more reliable than any method in
which a spirit level is employed.
[Illustration: Fig. 657.--Interior view of Thompson watt hour meter (type
CQ). The capacities of this type range from 50 to 400 amperes inclusive,
two wire, and 50 to 200 amperes inclusive, three wire, and for voltages
of from 100 to 600 volts. These meters are made with either front or back
connections. In front connected meters the positions of the leading-in
wires and cables are the same as in the type C-6, fig. 654, so that either
type of meter may be installed in the same location.]
[Illustration: Fig. 658.--Specimen record from General Electric recording
ammeter. The record is made on a band of specially prepared paper four
inches wide and sixty feet in length. On this paper are ruled lines
corresponding to time, and the instrument calibration. The lines ruled
across the paper represent time; those ruled lengthwise represent volts,
amperes, or watts, depending upon the instrument construction. This
form of paper has the advantage of permitting the use of time divisions
of equal length throughout the entire range of the recording pen. The
recording pen is attached to the moving element in such a manner that its
motion is transmitted in a straight line parallel to the time division on
the chart. As the paper is unwound and passed under the recording pen, it
is paid into a space at the bottom of the instrument case. To assist in
removing paper, the instrument is provided with a stripper, which enables
the paper to be torn off evenly and without damage. The paper feeding
mechanism is simple. By means of suitable gearing, the clock drives a
drum having peg teeth which engage the holes located near the edge of the
paper. These teeth not only feed the paper under the recording pen, but
also give it a definite and accurate position along the axis of the drum.
The feeding drum is driven by a friction clutch.]
[Illustration: Fig. 659.--Westinghouse type CW-6 watt hour meter with
cover off. This meter is of the commutator type without iron in the
magnetic circuit. The spherical armature is closely surrounded by circular
field coils which provide the shortest magnetic path and smallest magnetic
leakage, thus securing high torque with small consumption of energy. The
armature winding is wound on a hollow sphere of prepared paper which is
moulded in corrugated form to secure strength. Uniform brush tension is
maintained by gravity. Each brush consists of two small round wires placed
side by side and held against the commutator by a small counterweight
whose distance from the fulcrum is adjustable. The current winding
consists of two flat coils of strap copper, one clamped rigidly on either
side of the central mounting frame which supports the armature bearings.
These coils are connected either in series or parallel, depending on the
capacity. In three wire meters one of the coils is connected in series
with each side of the line. The retarding element consists of a light
aluminum disc rotating between two pairs of permanent magnets. The magnets
are prepared by a special aging process to insure permanence. Full load
adjustment is made by shifting the position of the permanent magnets.
Ample light load adjustment or friction compensation is provided by means
of the movable coil, which can be shifted horizontally or radially on
loosening one screw. The meter registers directly in kilowatt hours.]
[Illustration: Fig. 660.--Interior of Thompson prepayment watt hour meter.
The actuating force is a large flat coil spring enclosed in a barrel or
drum to which its outside end is attached. The operating knob winds this
main spring by turning the drum. The spring has many turns and as the
operation of the device never equals one whole turn, the spring always
exerts a practically constant force. The rate device consists of a small
train of gears secured to the front of the frame directly back of the
register. Each device is marked with the price per kw-hr. for which it
should be used. The switch is of the double pole double break type with
leaf contacts. The coin receptacles are placed at the back of the meter.
To make an advance payment, the winding knob is turned so that the arrow
points upward. A quarter dollar is then inserted in the slot and the
knob turned to the right, the coin serving as a key which operates the
mechanism within the device, turning the registering wheel and placing
the coin to the credit of the customer. If the circuit be open when the
coin is deposited the same motion of the knob which moves the registering
mechanism closes the circuit switch contained within the case. The dial
contains a scale marked in plain figures over which a pointer passes
indicating the number of coins remaining to the credit of the depositor.
When the first coin is deposited and the knob turned closing the main
switch, the pointer rests opposite the first division on the scale. If a
second coin be deposited before the current purchased with the first coin
has been consumed, a second motion of the knob will bring the pointer
opposite the second division on the scale. Twelve coins can thus be
deposited consecutively, after which the slot is automatically closed and
further prepayment cannot be made until the value of one or more coins has
been consumed. Whenever energy to the value of one coin has been delivered
through the meter, the escapement is mechanically released turning the
pointer back one division. This process continues until all the energy
has been delivered for which payment has been made. Thus the depositor
can ascertain at any time how much energy can be obtained without further
payment. When all energy has been delivered, the circuit switch is opened
so that no more current can be obtained until one or more coins have
been deposited. The indicating mechanism shows only the number of coins
which stand to the credit of the customer, but, by consulting the meter
dial, one can determine what fractional part of the prepayment next to be
cancelled remains to the credit of the customer. A coin or washer larger
than the coin for which the device is designed cannot be introduced into
the receiving slot and a smaller one will not operate the device.]
How to test a meter.--A simple test for ascertaining whether a customer's
meter is fast or slow[C], may be applied as follows:
1. Turn off the lamps and other power consuming devices in the house
and then note the reading of the meter dial and the exact time of day;
2. Turn on as quickly as possible about one-tenth of all the lamps in
the house and allow them to burn for about two hours;
3. At the end of two hours, turn off the lamps as quickly as possible
and note the reading of the meter dial.
The difference between the first and second readings of the dial will be
the indicated consumption of two hours, and if this be greater than the
amount of power that ought to be consumed by the number of lamps turned
on, the meter is fast, but if it be less, the meter is slow.
The best results obtained by this method are only approximations, however,
on account of the variations in the watts consumed by the different makes
of lamp, the uncertainty as to the actual voltage on the line at the
time of the test, and the lack of knowledge as to the age of the lamps.
Therefore, if the meter test within five per cent., or do not record more
nor less than one-twentieth of the assumed lamp consumption it is safe to
assume that the meter is correct as the result of the test is not likely
to be any closer to the truth.
[C] NOTE.--A meter operates under more varied and exacting conditions
than almost any other piece of apparatus. It is frequently subjected
to vibration, moisture and extremes of temperature; it must register
accurately on varying voltages and various wave forms; it must operate
for many months without any supervision or attention whatever; and, in
spite of all these conditions, it is expected to register with accuracy
from a few per cent. of its rated capacity to a 50 per cent. overload.
As a meter is a type of machine, its natural tendency is to run slow;
but occasionally, through accident, a meter may run fast. When a meter
runs fast the consumer is paying a higher rate per kilowatt hour than
his contract calls for. He is being discriminated against. The periodic
testing of meters is therefore a necessity and is an indication of the
honesty of intention of the manager toward the customers of his company.
Meters controlling a very large amount of revenue may be tested as often
as once a month, while the ordinary run of meters should be tested at
least once a year, once in eighteen months, or once in two years, the
period varying with different companies, different types and different
civic requirements. Commutator type meters, having comparatively heavy
moving elements with consequent rapid increase in friction due to wear
on the jewel and bearings, and a commutator also increasing in friction
with age, must have frequent and expert attention to insure their accuracy
under all conditions.
Ques. How should a roughened commutator be cleaned and smoothed?
Ans. By means of tape.
[Illustration: Fig. 661.--Internal connections of Sangamo watt hour
meter (type D). A, copper disc armature, submerged in mercury; B, bridge
wire between binding posts, for main load current, when both sides of
the line are carried through the meter; CT, compounding series turns
around pressure circuit magnet, building up field as load increases,
to compensate for falling off in speed otherwise found; D, aluminum
damping, or brake disc, controlling speed of meter; E, copper contact
ears, imbedded in insulating wall of mercury chamber, leading current
into and out from armature; F, hardwood float on armature proportioned to
give slight "lift" to entire moving system, when armature and float are
immersed in mercury; H, soft steel disc above permanent magnets, riveted
to fine pitch screw working in bracket above, so that adjustment of the
disc up or down gives variation in damping effect of permanent magnets,
and therefore of main speed. K, clamp slider with thumb screw, for
obtaining light load adjustment by moving K to right or left, as may be
necessary. K spans and connects parallel wires of light load adjustment,
BR and RR'. MM, powerful permanent magnets, acting on disc D, giving main
speed control for meter. N, high resistance heavy wire, forming part of
series adjustment between armature and any shunt with which meter may
be used, to set drop through meter correct for drop of the shunt. P,
spirally laminated soft steel ring, moulded in mercury chamber above the
armature space, to act as a return for magnetic lines of force from and to
energizing magnet below. R, resistance card unit, in series with pressure
circuit coils; in 110 volt meters one card is used, in 220 volt meters two
cards, or one card and a thermocouple. BR, small brass wire, connected
to ingoing end of pressure circuit coils and forming RR' and the slides
K the light load adjustment. RR', high resistance wire having opposite
ends connected to ears EE by low resistance wires. Current energizing the
pressure circuit coils SC passes from RR' through K to BR and thence to
the coils, and if K be near the end of RR' and BR, the least compensation
is obtained; if near right end, maximum light load compensation is
obtained. S, shaft or spindle. In actual meter S is divided, the lower
shaft carrying armature A, and the upper shaft damping disc D. SA, series
resistance adjustment, for setting meter to correct drop for shunt. SC
and SC', pressure coils connected in series. TT, binding posts at bottom
of meter. Y, laminated soft steel yoke, carrying coils SC and SC', and
giving a powerful and concentrated magnetic field on the armature. W,
worm, driving recording dial train. WW, worm wheel.]
[Illustration: Fig. 662.--Interior view of Columbia watt hour meter
(type D), showing construction and principal parts and connections. The
armature winding consists of three coils approximately circular in shape.
The coils are form wound, interlocked with one another and with the light
impregnated fibre disc which serves as a spacer for them. The aluminum
damper disc has the conventional anti-creep provision in the shape of the
three small soft iron plugs, mounted close to the central staff, which the
illustration shows. These in their revolution come successively within the
influence of an adjustable iron screw which is magnetized by an extension
from one of the damper magnets. The angular relationship of the armature
windings and of the three iron plugs is such that at the time that the
armature is exerting a maximum torque the magnetized screw is exerting the
maximum pull to hold back a given plug and conversely when the armature
pull is a minimum the magnetic screw is attracting a plug with the
maximum effort to cause ahead rotation. The irregularities of torque are
in this way smoothed out. The commutator has three segments and is made
of chemically pure silver. Each brush is formed of a length of phosphor
bronze wire bent like a hair pin and secured at its "U" end to a brass
sleeve, which in turn is secured to an insulated stud by a set screw.
An extension on the sleeve carries a micrometer screw brush adjustment.
The main speed adjustment is secured by providing a soft iron bridge
plate, bridging over the extremities of each magnet end and adjustable,
by means of a set screw and lock nut, to any desired distance therefrom.
This gives a regular micrometer means of varying the effective magnet
strength. Interposed between the series coil and the permanent magnets is
a heavy soft iron shield to guard the magnets against disturbance by short
circuiting. Light load adjustment is obtained by providing in the coil
circuit a series of small resistance spools, equipped with pin terminals,
to which connection can be selectively made by means of a split bushing
terminal on a flexible cord. This series of spools is strung on a metal
arbor located within the case.]
[Illustration: Fig. 663.--Diagram showing internal connections of the
Duncan watt hour meter. Its operation depends upon the principle of
the well known electro-dynamometer, in which the electromagnetic action
between the currents in the field coils and an armature produces motion
in the latter. It also embodies the other two necessary watt hour
meter elements required for the speed control and registration of the
revolutions of the armature, these being embodied in the drag magnet and
disc, and the meter register respectively. The motion of the armature is
converted into continuous rotation by the aid of a commutator and brushes,
the commutator being connected to the armature coils and carried on the
same spindle therewith.]
Waste of Electricity in Lighting.--In large residences where a good many
servants are employed or in any place where the power consumed is not
directly under the supervision of the person who must pay the bills, a
great deal of waste usually occurs.
If the meter be read before retiring, the reading in the morning will show
how much energy was consumed during the night, which will show in turn
how many lamps were burning all night.
A great deal of light can be saved by placing the lamps so that they will
throw the light where it is needed and by placing small lamps such as 8
candle power and 4 candle power in places where not much light is needed,
such as bathrooms, halls, cellars, etc.
When the lamps get old and dim they should be replaced with new ones, as
it costs about the same to burn an old lamp as a new one. An old 16 candle
power lamp which is very dim will give only about 8 candle power and use
about as much current as is required for a new 16 candle power. If the dim
light be light enough, it should be replaced by an 8 candle power lamp,
which will not consume as much power as the old 16 candle power.
CHAPTER XXIX
OPERATION OF DYNAMOS
Before Starting a Dynamo or Motor.--When the machine has been securely
fixed, it should be carefully examined to see that all parts are in good
order. The examination should be made as follows:
1. The field magnet circuit should first be inspected to see that none
of the wires or connections have broken or have become loose, and that
the coils are correctly connected;
2. The caps of the bearings should be taken off, and these and the
journals carefully cleaned of all grit and dirt. They should then be
oiled, and the caps replaced and screwed up by hand only;
3. The gaps between the outer surface of the armature and the polar
faces should be examined in order to ascertain whether any foreign
body, such as a small screw or nail has lodged therein. If such be
the case, it should be carefully removed with a bit of wire;
4. The guard plates protecting the armature windings should be removed,
and the windings carefully inspected by slowly rotating the armature,
to see that they are not damaged, and that the insulation is perfect.
The armature should then be finally rotated by hand to see that it
revolves freely, and that the bearings are securely fixed;
5. The commutator should be examined to see that it is not damaged in
any way through one or more of the segments being knocked in, or the
lugs being forced into contact with one another;
6. The brush holders and brushes should be inspected to see that the
former work freely on the spindle, and that the hold off catches work
properly, are clean and make good contact with the brush holders or
flexible leads;
7. Having ascertained that the machine is not injured in any way, and
that the armature revolves freely, the brushes should be adjusted.
In the subsequent working of the dynamo it will of course be
unnecessary to follow the whole of these proceedings every time the
machine is started, as it is extremely unlikely that the machine will
be damaged from external causes while working without the attendant
being aware of the fact.
Adjusting the Brushes.--The _adjustment of the brushes_ upon the
commutator requires careful attention if sparking is to be avoided. There
are two adjustments to be made:
1. For pressure; The brushes must bear against the commutator segments
with sufficient pressure for proper contact.
2. For lead. The brushes must have the proper angular advance (positive
or negative, according as the machine is a dynamo or motor) to prevent
sparking.
Ques. At what point on the commutator should the brushes bear?
Ans. The points upon the commutator at which the tips of the brushes
(carried by opposite arms of the rocker) bear, should be, in bipolar
dynamos, at opposite extremities of a diameter. In multipolar dynamos the
positions vary with the number of poles and the nature of the armature
winding.
Ques. What provision is made to facilitate the correct setting of the
brushes?
Ans. Setting marks are usually cut in the collar of the commutator next
to the bearing.
[Illustration: Figs. 664 and 665.--Diagrams illustrating how to set
brushes. Some brush holders require brushes set _with_ the direction of
rotation of the commutator, and others, set _against_ the direction of
rotation. In fig. 664 is shown a brush holder of the first class, which
must always be set as indicated by the arrow. If set in the opposite
direction, trouble will ensue, as an inspection of the figure will show,
because the surface of the commutator and the brush would form a toggle
joint, and the brush would tend to dig into the commutator and either
break itself or bend the brush rigging. In fig. 665 is shown a brush
holder of the second type. This brush is set against the direction of
rotation, but an inspection of the cut will show that there is, in this
case, no tendency for the brush to dig into the commutator surface. Each
type of brush holder, of which there are several, should be adjusted as
recommended by the manufacturer to secure proper working.]
Ques. How are the brushes set by these marks?
Ans. The tips of all the brushes carried by one arm of the rocker are set
in correct line with the commutator segments marked out by one setting
mark, and the tips of the brushes carried by the other arm or arms are set
in correct line with the segments marked out by the other mark or marks.
If one or more of the brushes in a set be out of line with their
setting mark, it will be necessary to adjust the brushes up to this
mark by pushing them out or drawing them back, as may be required,
afterwards clamping them in position. When adjusting the brushes,
the armature should always be rotated, so that the setting marks are
horizontal. The rocker can then be rotated into position, and the
tips of both sets of brushes conveniently adjusted to their marks. In
those brush holders provided with an index or pointer for adjusting
the brushes, the setting marks upon the commutator are absent, length
of the pointer being so proportioned that when the tips of the brushes
are in line with the extreme tips of the pointers, the brushes bear
upon the correct positions on the commutator.
[Illustration: Fig. 666.--Method of soldering cable to carbon brush. Drill
a hole in the end, also in the side of the brush, as shown in the sketch,
and after thoroughly tinning the "pig-tail," place it in the end hole and
fill the holes up with solder through the side hole. Another method is to
drill a hole through the carbon so that the cable will just slip through,
countersink the edge of the hole a little, clean the cable thoroughly and
pass it through the hole. Then with any good flux and solder, fill the
countersunk part on both sides.]
Ques. What should be done after adjusting the brushes to their correct
positions upon the commutator?
Ans. Their tips or rubbing ends should be examined while in position to
see that they bed accurately on the surface of the commutator.
In many instances it will be found that this is not the case, the
brushes sometimes bearing upon the point or toe, and sometimes
upon the heel, so that they do not make contact with the commutator
throughout their entire thickness and width. The angle of the rubbing
ends will therefore need to be altered by filing to make them lie
flat.
Ques. How is the proper brush contact secured?
Ans. When the brushes do not bed properly they should be refitted to
secure proper contact.
Ques. How is the pressure adjustment made?
Ans. This is effected by regulating the tension of the springs provided
for the purpose upon the brush holders.
Ques. With what pressure should the brushes bear against the commutator?
Ans. The tension of the springs should be just sufficient to cause the
brushes to make a light yet reliable contact with the commutator.
The contact must not be too light, otherwise the brushes will vibrate,
and thus cause sparking; nor must it be too heavy, or they will press
too hard upon the commutator, grinding, scoring and wearing away the
latter and themselves to an undesirable extent, and moreover, giving
rise to heating and sparking.
The correct pressure is attained when the brushes collect the full
current without sparking, while their pressure upon the commutator is
just sufficient to overcome ordinary vibration due to the rotation of
the commutator.
[Illustration: Figs. 667 to 669.--Method of winding cables with marlin.
When connecting the feeders and dynamo and service leads to a switchboard,
the wires are often _served_ with marlin. By serving is meant to tightly
wrap the wires of each set together with marlin. A tool for serving may be
made as in fig. 667, using a piece of oak 2 ins. wide, 7/8 in. thick and
14 ins. long, having four holes drilled through it, as shown. The marlin
is passed through the holes, commencing at the hole nearest the handle,
the object being to cause a strain on the marlin at the point where it
passes around the wire, so that the marlin may be wrapped tightly. It
is necessary to serve the first four or five inches by hand, pushing the
winding into the conduit as far as possible. This acts as an additional
protection to the wires where they leave the conduit. The serving is
continued, as in fig. 668, to within four or five inches of the first
lug by means of the serving tool, passing the ball of marlin around the
wires with the serving tool. The wires are then bent in shape, as in fig.
669. To serve the wires properly it is necessary to tie the ends of the
wires taut. The wires should be straightened and run together so as to
be parallel, being bound with tape at different points to keep them so.
When the serving is complete the marlin should be thoroughly painted with
a moisture resisting compound. The marlin serving will stiffen the wires
and they can be bent very neatly to avoid touching the bus bars of the
board. When painted the marlin hardens so that it is difficult to bend
the wires after the paint has dried. It then requires a strong pressure
to bend them. The marlin acts as an additional insulation and mechanical
protection to the wires, and while no harm would result from the wires
coming in contact with the bars while thus protected, it looks better to
bend them so as to avoid touching the bars.]
Direction of Rotation.--This is sometimes a matter of doubt and often
results in considerable trouble. As a general rule, a dynamo is intended
to run in a certain direction; either right handed or left handed
according to whether the armature, when looked at from the pulley end,
revolves with or against the direction of the hands of a clock. Dynamos
are usually designed to run right handed, but the manufacturers will make
them left handed if so desired.
It may be necessary to reverse the direction of rotation of a dynamo,
if the driving pulley to which it has to be connected happen to revolve
left handed, or if it be necessary to bring the loose side of the belt
on top of the pulley, or to place the machine in a certain position on
account of limited space. The direction of rotation of ordinary series,
shunt, or compound bipolar dynamos may be reversed by simply reversing the
brushes without changing any of the connections, then changing the point
of contact of the brush tips 180°.
In multipolar dynamos, a similar change, amounting to 90° for a four pole
machine, and 45° for an eight pole machine, will reverse their direction
of rotation. It will be understood that under these conditions, the
original direction of the current and the polarity of the field magnets
will remain unchanged.
This rule does not apply to arc dynamos and other machines, which have
to be run in a certain direction only, in order to suit their regulating
devices.
If the direction of current generated by a dynamo be opposite to that
desired, the two leads should be reversed in the terminals, or the
residual magnetism should be reversed by a current from an outside source.
[Illustration: Fig. 670.--Method of assembling core discs. For this
operation two wooden "horses" should be provided to support the core at
a convenient height, as shown in the illustration.]
Starting a Dynamo.--Having followed the foregoing instructions, all keys,
spanners, bolts, etc., should be removed from the immediate neighborhood
of the machine, and the dynamo started.
[Illustration: Figs. 671 and 672.--Tinning block for electric soldering
tool. It is made with two soft bricks. One brick is used to support the
soldering tool, and the other to contain the tinning material and to
furnish a material which will keep the copper bit bright enough to receive
its coating of "tin." Fig. 671 represents a section of the tinning brick,
which is scooped out on top as shown by the lower line. Into one end
of the hollow in the brick, some sal-ammoniac is placed to help tin the
copper bit. Sal-ammoniac is a natural flux for copper and aids greatly
in keeping the tool well tinned. Next, some melted solder is run into the
hollow of the brick, and lastly enough resin to fill the cavity nearly to
the top. When the tool is not in use, the electricity is switched off and
the tool permitted to lie in the resin. If it be desired to repair the
tin coating a little when the tool is in use, the latter is rubbed on the
brick below the layer of solder, and the layer of resin. If the tool be in
very bad condition, it may be pushed into the sal-ammoniac once or twice
and then rubbed in the solder again. It requires but little heat to keep
the brick and its contents ready for use. In fact, the brick is a fair
non-conductor of heat and prevents the escape of heat from one side of the
tool. When momentarily not in use, the tool remains in the solder which
becomes melted underneath the layer of resin. When the copper bit becomes
too hot, it will begin to volatilize the resin, thus calling attention to
this fact, whereupon, the electricity should be turned off from the tool.]
Ques. How should a dynamo be started?
Ans. A dynamo is usually brought up to speed either by starting the
driving engine, or by connecting the dynamo to a source of power already
in motion. In the first case, it should be done by a competent engineer,
and in the second case by a person experienced in putting on friction
clutches to revolving shafts, or in slipping on belting to moving pulleys.
[Illustration: Fig. 673.--Connections for two shunt wound dynamos to
run in parallel. The positive lead of each machine is connected to the
same bus bar. In starting, if but one machine is to be used, the dynamo
is first brought up to speed and the voltage regulated by means of the
rheostat R and the voltmeter V. The main switch is then thrown in. The
connections for the field are taken off the dynamo leads so that the
opening of the main switch will not open the field circuit and for this
reason the field will begin to build up as soon as the machine is started.
When but one of the machines is running, the idle machine is brought up to
speed with the main switch open, and the voltage regulated by means of the
rheostat and voltmeter until the voltages of the machines are the same.
Then the main switch is thrown in and the load on the machines (which
is ascertained by the ammeters) is equalized by means of the rheostats.
Should there be any great difference in voltages, the higher one will
run the other as a motor without changing the direction of rotation. The
field current will remain unchanged, and the armature current of the low
dynamo will be reversed, which will cause it to run as a motor in the same
direction as it ran as a dynamo. When dynamos feeding current to motors
are to be shut down, the switches on the motors should first be opened.
Otherwise some of the motor fuses will blow. As the voltage goes down the
motors will draw more current to do the work. If a plant be shut down with
the motor switches "in" it will generally be found impossible to start a
shunt dynamo, the low resistance in the mains not allowing enough current
to flow around the shunt fields to energize them.]
Ques. Should the brushes be raised out of contact in starting?
Ans. The brushes should not be in contact in starting if there be any
danger of reverse rotation, as might happen when the dynamo is driven
by a gas engine. Aside from this, it is desirable that the brushes be
in contact, because they are more easily and better adjusted, and the
voltage will come up slowly, so that any fault or difficulty will develop
gradually and can be corrected, or the machine stopped before any injury
is done.
[Illustration: Fig. 674.--Connections for two shunt dynamos to run on
the three wire system. The two machines are connected in series, three
wires being carried from them, one from the outside pole of each machine
and one from the junction of the two machines. The voltage between the
outside wires is equal to the combined voltage of the two machines and the
voltage between the outside and the central or neutral wire is equal to
the voltage of the corresponding machine. If the load on each side of the
system be equal, there will be no current in the neutral wire, while if
the loads be unequal, the neutral wire will have to carry the difference
in current between the two outside wires.]
Ques. How should a series machine be started?
Ans. The external circuit should be closed, otherwise a closed circuit
will not be formed through the field magnet winding and the machine will
not build up.
Ques. What is understood by the term "build up"?
Ans. In starting, the gradual voltage increase to maximum.
[Illustration: Fig. 675.--Connections for two compound wound dynamos to
run in parallel. The series fields of the machines are connected together
in parallel by means of wire leads or bus bars, which connect together
the brushes from which the series fields are taken. This is known as
the equalizer and is shown by the line running to the middle pole of the
dynamo switch. By tracing out the series circuits it will be seen that
current from the upper brush of either dynamo has two connections to its
bus bar. One of these leads through its own field, and the other, by means
of the equalizer bar, through the fields of the other dynamo. As long as
both machines are generating equally there is no difference of pressure
between the brushes of either, but should the voltage of one be lowered,
current from the other would flow through its fields and thereby raise
the voltage, and at the same time reduce its own until both are equal.
The equalizer may then be called upon to carry much current, but to have
the machines regulate closely it should be of low resistance. It may also
be run as shown by the dotted lines, but this will leave all the machines
alive when any one is generating. The ammeters should be connected as
shown. If they were on the other side they would come under the influence
of the equalizing current and would indicate wrong, either too high or
too low. The equalizer switch should be closed a little before the main
switches are closed.]
Ques. How should a shunt or compound machine be started?
Ans. All switches controlling the external circuits should be opened, as
the machine excites best when this is the case. If the machine be provided
with a rheostat or hand regulator and resistance coils, these latter
should all be cut out of circuit, or short circuited, until the machine
excites, when they can be gradually cut in as the voltage rises.
When the machine is giving the correct voltage, as indicated by the
voltmeter or pilot lamp, the machine may be switched into connection
with the external or working circuits.
Ques. In starting a shunt dynamo, should the main line switch be closed
before the machine is up to voltage or after?
Ans. If the machine be working on the same circuit with other machines, or
with a storage battery, it is, or course, necessary to make the voltage of
the machine equal to that on the line before connecting it in the circuit.
If the machine work alone, the switch may be closed either before or after
the voltage comes up. The load will be thrown on suddenly if the switch be
closed after the machine has built up its voltage, thus causing a strain
on the belt, and possibly drawing water over the engine cylinder. On the
other hand, if the switch be closed before the voltage of the machine has
come up, the load is picked up gradually, but the machine may be slow or
may even refuse to pick up at all.
Ques. Why does a shunt machine pick up more slowly if the main switch be
closed first?
Ans. Because the resistance of the main line is so much less than that
of the field that the small initial voltage due to the residual magnetism
causes a much larger current in the armature than in the shunt field. If
this be too large, the cross and back magnetizing force of the armature
weakens the field more than the initial field current strengthens it, and
so the machine cannot build up.
Ques. If a shunt dynamo will not pick up, what is likely to be the trouble?
Ans. The speed may be too slow; the resistance of the external circuit
may be too small; the brushes may not be in proper position; some of the
electrical connections in the dynamo may be loose, broken or improperly
made; the field may have lost its residual magnetism.
[Illustration: Figs. 676 and 677.--Diagrams of ground detectors. Fig. 676,
a ground detector switch suitable for mounting on a switch board. The two
arms pivoted at their upper ends are connected with an insulating bar A
and make contact at their lower ends with two brass strips and a contact
button, which are connected to the bus bars and ground, respectively.
When the arms are moved to the left, the positive bus bar is connected to
the ground through the voltmeter V. In fig. 677 is another form of ground
detector. This is known as a lamp ground detector. On a 110 volt system
two ordinary lamps are connected in series, while the line connecting the
lamps is connected to the ground through a snap switch S. When current
is on, the two lamps will burn with equal brilliancy, but at a lower
candle power. When the switch S is closed, if the two lines be clear, the
brilliancy of the lamps will not be affected, but if there be a ground on
the positive side, one lamp will burn brighter, the brightness depending
on the resistance of the ground. If there be a dead ground, the lamp will
burn to its full candle power.]
Ques. What is the indication that the connections between the field coils
and armature are reversed?
Ans. If the machine build up when brought to full speed, the connections
are correct, but if it fail to build up, the field coils may be improperly
connected.
[Illustration: Fig. 678.--Method of correcting reversed polarity in large
shunt dynamo by transposing the shunt field leads, and then starting up
the machine. As soon as the voltmeter registers any voltage, the dynamo
may be stopped and the field leads restored to their original position,
when it will be found that the residual magnetism in the pole pieces
will usually bring the dynamo up to its polarity and proper voltage.
This method has the disadvantages, of the uncertainty as to the machine
building up, and that a temporary wire must probably be run from the
switchboard to one terminal of the field circuit, which is usually
connected to a terminal back of the dynamo frame, so that the flow of
current through the field coils may be reversed. With dynamos having
laminated field magnet cores of comparatively low residual magnetism,
this method may suffice, but in the case of solid field magnetic cores it
is not practical. A better method is to disconnect the shunt field leads
and temporarily extend them to some other source of direct current. If
the current be of higher voltage than the coils are designed for, as for
instance 110 volt dynamo and available current 500 volt, caution must be
exercised and a suitable resistance be provided to protect the coils. A
500 volt coil, however, may be supplied from 110 volt circuit, providing
the field winding to be energized is equipped with a cut off switch
having a discharge resistance, so that it may be used to close and break
the circuit when the temporary leads have been connected. If the field
windings be not so provided, a bank of lamps or some other non-inductive
resistance must be connected across the leads between the field magnet
coils and the point at which the circuit is to be opened and closed. This
is to provide a path for the discharge of the induced electromotive force.
The circuit should not remain closed more than a few seconds if the full
voltage can be applied. It is well, however, to leave the current on long
enough to run the machine up to about half speed and make sure, by means
of a voltmeter, that the polarity has been corrected. When this has been
ascertained the dynamo should be stopped and the field winding leads
returned to their proper terminals. Then the voltage will be brought up
in the right direction, provided the work has been done correctly.]
This can be tested by connecting a voltmeter across the terminals
of the armature, or by means of a magnetic needle placed at a short
distance from one of the pole pieces in such a position that it
does not point to the north pole. If the field coils be improperly
connected, the current due to the initial voltage will weaken the
field magnetism and thus prevent the machine building up, and when the
field circuit is closed the voltmeter reading will be reduced, or the
magnetic needle will be less strongly attracted.
Ques. What will be the result if the connections of some of the field
coils of a dynamo be reversed?
Ans. If one-half the number of coils oppose the other half, the field
magnetism will be neutralized and the machine will not build up at all;
but if one of the coils be opposed to the others, the machine might build
up, but the generated voltage will be low, and there will be considerable
sparking at some of the brushes.
Ques. How may it be ascertained which coil is reversed?
Ans. In all dynamos there should be an equal number of positive and
negative poles, and in almost all of them the poles should be alternately
positive and negative. Therefore, if a pocket compass be brought near the
pole pieces, and it show that there are more poles of one kind than the
other, the indication is that one or more of the coils are reversed, and
the improper sequence of alternation will determine which one is wrongly
connected.
Ques. When a dynamo loses its residual magnetism, how can it be made to
build up?
Ans. By temporarily magnetizing the field. To do this a current is passed
through it from another dynamo, or from the cells of a small primary
battery. Usually, this will set up sufficient initial magnetism to allow
the machine to build up. The battery circuit should be broken before the
machine has built up to full voltage.
Ques. What should be done if a dynamo become reversed by a reversal of
its field magnetism due to lightning, short circuit, or otherwise?
Ans. The residual magnetism should be reversed by a current from another
dynamo, or from a battery; but if this be not convenient, the connections
between the machine and the line should be crossed so that the original
positive terminal of the dynamo will be connected to the negative terminal
of the line, and vice versa.
[Illustration: Fig. 679.--Method of correcting reversed polarity in
compound wound dynamo. The polarity may be reversed without disconnecting
or changing the wire. The figure shows two compound dynamos, and essential
connections. The current from any machine connected to the equalizer bar
by its equalizer switch will divide, a portion going through the series
field winding of the other machines connected to the bus bar, the division
being determined by the resistance of the different sets of coils. For
instance, assume that No. 1 dynamo has had its polarity reversed and
that No. 2 is running connected to the bus bar. The method of reversing
the polarity of No. 1 machine is as follows: No. 1 machine should be at
rest and then make sure that the circuit breaker and negative switch
are open and that any other special connections to other machine or
station lighting circuits are open. Then close the positive and equalizer
switches, thus allowing a part of the current from the other dynamo to
pass through the equalizer connection and through the series field winding
of No. 1 machine in the usual direction, which will magnetize the magnetic
core. If No. 1 machine be a large unit and No. 2 a small unit, it will be
necessary to cut out the resistance of the shunt field circuits by means
of the rheostat, if it be desired to maintain its bus bar voltage at its
normal point. This will rob the series winding of any other machines which
may be connected to the bus bars and will lower the voltage slightly. No.
1 machine is then brought up to full speed when it will be found to have
recovered its correct polarity. The positive switch may be readily opened,
watching the bus bar voltage closely as it will rise when the current is
restricted again to the series field winding of the other machines. The
dynamo will then be ready to cut in with the other machines as soon as the
voltage has been brought up to the proper point, or it may be shut down
until required.]
Ques. Can a dynamo be reversed by reversing the connections between the
field coils and the armature?
Ans. No, for if these connections be reversed, the machine will not build
up.
Ques. Will a dynamo build up if it become reversed?
Ans. Yes.
Ques. Then what is the objection to a reversed dynamo?
Ans. Since the direction of current of a reversed dynamo is also reversed,
serious trouble may occur if it be attempted to connect it in parallel,
with other machines not reversed.
Attention while Running.--When a dynamo is started and at work, it will
need a certain amount of attention to keep it running in a satisfactory
and efficient manner. The first point to be considered is the adjustment
of the brushes. If this be neglected, the machine will probably spark
badly, and the commutator and brushes will frequently require refitting
to secure good contact.
Ques. What may be said with respect to the lead of the brushes?
Ans. The lead in all good dynamos is very small, and varies with the load
and class of machine. The best lead to give to the brushes can in all
cases be found by rotating the rocker and brushes in either direction
to the right or left of the neutral plane until sparking commences,
increasing with the movement. The position midway between these two points
is the correct position for the brushes, for at this position the least
sparking occurs, and it is at this position that the brushes should be
fixed by clamping the rocker.
[Illustration: Fig. 680.--Method of taking temperature. In taking the
temperature of a hot part, it is convenient to use a thermometer in which
the scale of degrees has been etched on the stem. Bind this to the heated
part, having first taken the precaution to cover the bulb with waste
to prevent the radiation of heat and take the reading when the column
of mercury has ceased to rise. The question which most often presents
itself to the attendant is how hot can the various parts of a dynamo or
motor become and yet be within the safe limit. The degree of heat can
be determined by applying the hand to the various parts. If the heat be
bearable it is entirely harmless, but if the heat become unbearable to the
hand for more than a few seconds, the safety limit has been reached and
the machine should be stopped and the fault located. Of course when the
solder begins to melt at the commutator connections and shellac begins to
"fry out" of the armature and an odor of burnt cotton begins to pervade
the air, the safe limit has been far exceeded, and in most cases, as a
matter of fact serious damage is the result. To be more definite, _no part
of the dynamo or motor should be allowed to rise in temperature more than
80 degrees F. above the temperature of the surrounding air_, excepting
in the case of commutators where no solder has been used to connect the
leads. These can be allowed to rise to a still higher temperature.]
Ques. How does the lead vary in the different types of dynamo?
Ans. In series dynamos giving a constant current, the brushes require
practically no lead. In shunt and compound dynamos the lead varies with
the load, and therefore the brushes must be rotated in the direction of
rotation of the armature with an increase of load, and in the opposite
direction with a decrease of load.
In cases where the dynamos are subjected to a rapidly varying or
fluctuating load, it is of course not possible to constantly shift
the brushes as the load varies, therefore the brushes should be
fixed in the positions where the least sparking occurs at the moment
of adjustment. If at any time violent sparking occur, which cannot
be reduced or suppressed by varying the position of the brushes
by rotating the rocker, the machine should be shut down at once,
otherwise the commutator and brushes are liable to be destroyed,
or the armature burnt up. This especially refers to high tension
machines.
Ques. What should be done if the brushes begin to spark excessively?
Ans. First, look at the ammeter to see if an excessive amount of current
is being delivered; second, see if the brushes make good contact with the
commutator, and if the latter have a bar too high, or too low, and an open
circuit.
[Illustration: Figs. 681 and 682.--Remedies for leakage of oil from
self-oiling bearings. If there be sufficient space, a metal ring may be
attached to the shaft as in fig. 681. With this arrangement the high speed
of the shaft will carry the oil outside of the ring and throw it off in
the oil reservoir. Another way is to insert a tin apron, as shown in fig.
682 at T, which will serve to drain the oil which may creep along the
shaft, and also cut off the draft from the pulley which may suck the oil
out of the bearing. Sometimes a tin fan is attached to the pulley, which
tends to drive the oil back into the bearing, and which also assists in
keeping the box cool.]
Ques. What should be done if the current be excessive?
Ans. If the current exceed the rated capacity by more than 50 per cent.,
and continue for more than a few minutes, the main switch should be
opened, otherwise the machine may be seriously injured.
Ques. How does an excessive current injure a dynamo?
Ans. By causing it to overheat which destroys the insulation of the
armature, commutator, etc.
Lubrication.--The shaft bearings of dynamos may be lubricated by sight
feed oilers or oil rings. The latter method is almost universally used.
An oil well is provided in the hollow casting of the pedestals as shown
in fig. 728. Oil rings revolve with the shaft and feed the latter with
oil, which is continuously brought up from the reservoir below. The dirt
settles to the bottom and the upper portion of the oil remains clear for
a long period, after which it is drawn off through the spigot and a fresh
supply poured in through openings provided in the top. The latter are
often located directly over the slots in which the rings are placed, so
that the bearings can be lubricated directly by means of an oil cup, if
the rings fail to act or the reservoir become exhausted.
[Illustration: Fig. 683.--Imaginative view of a shaft showing its rough
granular structure. In operation these minute irregularities interlock and
act as a retarding force, or frictional resistance. Hence, the necessity
for lubrication--a lubricant presents a thin intervening film against
which the surfaces rub.]
Ques. What kind of oil can should be used in filling the reservoir, or
oil cups?
Ans. One made of some non-magnetic material such as copper, brass, or zinc.
If iron cans be used, they are liable to be attracted by the field
magnets, and thus possibly catch in the armature.
Ques. What is the indication of insufficient lubrication?
Ans. The bearings become unduly heated.
Ques. What precaution should be taken with new dynamos?
Ans. They are liable to heat abnormally and for the first few days they
should be carefully watched and liberally supplied with oil.
After a dynamo has been running for a short time under full load, its
armature imparts a certain amount of heat to the bearings, a little
more also to the bearing on the commutator end of shaft; beyond
this there is no excuse for excessive heating. The latter may result
from various causes, some of which are given with their remedies, as
follows:
1. A poor quality of oil, dirty or gritty matter in the oil;
2. Journal boxes too tight;
3. Rough journals, badly scraped boxes;
4. Belt too tight;
5. Bearings out of line;
6. Overloaded dynamo;
7. Bent armature shaft.
Ques. What is the allowable degree of heating?
Ans. It may be taken as a safe rule that no part of a working dynamo
should have a temperature of more than 80° Fahr. above that of the
surrounding air.
Accordingly, if the temperature of the engine room be noted before
applying the thermometer to the machine, it can at once be seen if the
latter be working at a safe temperature. In taking the temperature,
the bulb of the thermometer should be wrapped in a woolen rag. The
screws and nuts securing the different connections and cables should
be examined occasionally, as they frequently work loose through
vibration.
[Illustration: Fig. 684.--Diagram illustrating forces acting on a dynamo
armature. In the figure the normal field magneto-motive force is in the
direction of the line 1, 2, produced by the field circuit G, if there were
no current in the armature. But as soon as the armature current flows, it
produces the opposing force 3, 4, which must be combined with 1, 2 to give
the resulting force to produce magnetism and hence voltage. The resultant
1, 5, if 3, 4 be large enough, does not differ much from the original
force 1, 2. Or, expressed in a more physical way, the brushes E, F, rest
on the commutator and all the turns embraced by twice the angle 6, 3, F,
oppose the flow of flux through the armature core as well as all the turns
embraced by twice the angle, 7, 3, E. The remaining turns distort the
flux, making the pole corners at A and B denser, and at C and D rarer. So
that all the effect is to kill an increase of flux, or voltage. This cross
magnetism tends also to decrease the flow of flux, for the extra ampere
turns required to force the flux through the dense pole tips are greater
than the decreased ampere turns relieved by the reduction of flux at the
other pole tips; this follows, since iron as it increases in magnetic
density requires ampere turns greater in proportion than the increase of
flux.]
Instructions for Stopping Dynamos.--When shutting down a machine, the load
should first be gradually reduced, if possible, by easing down the engine;
then when the machine is supplying little or no current, the main switch
should be opened. This reduces the sparking at the switch contacts, and
prevents the engine racing.
When the voltmeter almost indicates zero, the brushes should be raised
from contact with the commutator. This prevents the brushes being damaged
in the event of the engine making a backward motion, which it often does,
particularly in the case of a gas engine. On no account, however, should
the brushes be raised from the commutator while the machine is generating
any considerable voltage; for not only is the insulation of the machine
liable to be damaged, but in the case of large shunt dynamos, the person
lifting the brushes is liable to receive a violent shock.
Ques. What attention should the machine receive after it has been shut
down?
Ans. It should be thoroughly cleaned. Any adhering copper dust, dirt,
etc., should be removed from the armature by dusting with a stiff brush,
and the other portions of the machine should be thoroughly cleaned with
linen rags. Waste should not be used, as it is liable to leave threads or
fluff on the projecting parts of the machine, and on the windings of the
armature, which is difficult to remove.
Ques. What attention should be given to the brushes and brush gear?
Ans. They should be examined and thoroughly cleaned. If necessary the
brushes should be refitted and readjusted. All terminals, screws, bolts,
etc., should be carefully cleaned and screwed up ready for the next run.
The brush holders should receive special attention, as when dirty, they
are liable to stick and cause sparking. All dirt and oil should be removed
from the springs, contacts, pivots, and other working parts.
It is advisable at stated intervals to entirely remove the brush
holders from the rocker arms, and give them a thorough cleaning by
taking them to pieces, and cleaning each part separately with emery
cloth and benzoline or soda solution.
Another point to which particular attention should be given is the
cleaning of the brush rocker. This being composed wholly of metal, and
the two sets of positive and negative brushes being only separated
from it by a few thin insulating washers, it follows that if any
copper dust given off by the brushes be deposited in the neighborhood
of these washers, there is considerable liability for a short circuit
of the machine to occur by the dust bridging across the insulation.
Ques. What further attention should be given?
Ans. It is a good plan, when the machine has been thoroughly cleaned and
all connections made secure, to occasionally test the insulation of the
different parts. If a record be kept of these tests, any deterioration of
the insulation can at once be detected, localized and remedied before it
has become sufficiently bad to cause a breakdown.
As a means of protecting the machine from any moisture, dirt, etc.,
while standing idle, it is advisable to cover it with a suitable
waterproof cover.
CHAPTER XXX
COUPLING OF DYNAMOS
Series and Parallel Connections.--When it is necessary to generate a
large and variable amount of electrical energy, as must be done in central
generating stations, apart from the question of liability to breakdown, it
is neither economical nor desirable that the whole of the energy should
be furnished from a single dynamo. Since the efficiency of a dynamo is
dependent upon its output at any moment, or the load at which it is worked
(the efficiency varying from about 95 per cent. at full load to 80 per
cent. at half load), it is advisable in order to secure the greatest
economy in working, to operate any dynamo as near full load as possible.
Under the above circumstances, when the whole of the output is
generated by a single dynamo this can evidently not be effected, for
the load will naturally fluctuate up and down during the working
hours, as the lamps, motors, etc., are switched into and out of
circuit; hence, although the dynamo may be working at full load
during a certain portion of the day, at other times it may probably
be working below half load, and therefore the efficiency and economy
in working in such an arrangement is very low.
Ques. How is maximum efficiency secured with variable load?
Ans. It is usual to divide up the generating plant into a number of units,
varying in size, so that as the load increases, it can either be shifted
to machines of larger size, or when it exceeds the capacity of the largest
dynamo, the output of one can be added to that of another, and thus
the dynamos actually at work at any moment can be operated as nearly as
possible at full load.
Ques. What should be noted with respect to connecting one dynamo to
another?
Ans. It is necessary to take certain precautions (as later explained) in
order that the other dynamos may not be affected by the change, and that
they may work satisfactorily together.
Ques. What are the two methods of coupling dynamos?
Ans. They are connected in series, or in parallel.
In coupling dynamos in series, the current capacity of the plant is
kept at a constant value, while the output is increased in proportion
to the pressures of the machines in circuit.
When connected in parallel, the pressures of all the machines are kept
at a constant value, while the output of the plant is increased in
proportion to the current capacities of the machines in circuit.
Coupling Series Dynamos in Series.--Series wound dynamos will run
satisfactorily together without special precautions when coupled in
series, if the connections be arranged as in fig. 685.
The positive terminal of one dynamo is connected to the negative
terminal of the other, and the two outer terminals are connected
directly to the two main conductors or bus bars through the ammeter
A, fuse F, and switch S. If it be desired to regulate the pressure
and output of the machines, variable resistances, or hand regulators
R, R^1, may be arranged as shunts to the series coils as shown, so as
to divert a portion or the whole of the current therefrom.
Series Dynamos in Parallel.--Simple series wound dynamos not being
well adapted for the purpose of maintaining a constant pressure, are in
practice seldom coupled in parallel; the conditions or working, however,
derive importance from the fact that compound dynamos, being provided with
series coils, are subject to similar conditions when working in parallel,
which is frequently the case.
Ques. What may be said with respect to coupling two or more plain series
dynamos in parallel?
Ans. The same procedure cannot be followed as in the case of plain shunt
dynamos, for the reason that if the voltage of the dynamo to be coupled
be exactly equal to that of the bus bars when connected in parallel, the
combination will be unstable.
[Illustration: Fig. 685.--Diagram showing method of coupling series
dynamos in series. R and R' are two hand regulators which are placed in
shunt across the coil terminals to regulate the pressure and output of
the machine.]
Ques. Why is this?
Ans. If, from any cause, the pressure at the terminals of one of the
dynamos fall below that of the others, it immediately takes a smaller
proportion of the load; as a consequence, the current in its field coils
is reduced, and a further fall of pressure immediately takes place. This
again causes the dynamo to relinquish a portion of its load, and again
occurs a further fall of pressure. Thus the process goes on, until finally
the dynamo ceases to supply current, and the current from the other
dynamos flowing in its field coils in the reverse direction reverses its
magnetism, and causes it to run as a motor against the driving power in
the opposite direction to that in which it previously ran as a dynamo.
Under such circumstances the armature is liable to be destroyed if
the fuse be not immediately blown, and in any case it is subjected to
a very detrimental shock. This tendency to reverse in series dynamos
can be effectually prevented by connecting the field coils of all the
dynamos in parallel.
[Illustration: Fig. 686.--Diagram showing method of coupling series
dynamos in parallel. In the diagram A, A', are ammeters; F, F', fuses; S,
S', switches.]
Ques. How are the field coils of all the dynamos connected in parallel?
Ans. This is effected in practice by connecting the ends of all the series
coils where they join on to the armature circuit by a third connection,
called the "equalizing connection," or "equalizer," as shown in fig. 686.
Ques. What is the effect of the equalizer?
Ans. The immediate effect is to cause the whole of the current generated
by the plant to be divided among the series coils of the several dynamos
in the inverse ratio of their resistance, without any regard as to whether
this current comes from one armature, or is divided among the whole. The
fields of the several dynamos being thus maintained constant, or at any
rate being caused to vary equally, the tendency for the pressure of one
dynamo to fall below that of the others is diminished.
Shunt Dynamos in Series.--The simplest operation in connection with the
coupling of dynamos, and the one used probably more frequently in practice
than any other, is the coupling of two or more shunt dynamos to run either
in series or in parallel. When connected in series, the positive terminal
of one machine is joined to the negative of the other, and the two outer
terminals are connected through the ammeter A, fuses F, F', and switch S,
to the two main conductors or omnibus bars as represented in fig. 687. The
machine will operate when the connections are arranged in this manner,
if the ends of the shunt coils be connected to the terminals of their
respective machines.
Shunt Dynamos in Parallel.--The coupling of two or more shunt dynamos
to run in parallel is effected without any difficulty. This method of
coupling dynamos is one that is very frequently used. Fig. 688 illustrates
diagrammatically the method of arranging the connections. The positive
and negative terminals of each machine are connected respectively to two
massive insulated copper bars, shown at the top of the diagram, called
_omnibus bars_, through the double pole switches, S, S', and the double
pole fuses F, F'. Ammeters, A, A' are inserted in the main circuit of each
machine, and serve to indicate the amount of current generated by each.
An automatic switch or cutout, Ac, Ac', is also shown as being included
in the main circuit of each of the machines, although this appliance
is sometimes dispensed with. The pressure of each of the machines is
regulated independently by means of the hand regulators R, R', inserted
in series with the shunt circuit.
The shunt circuits are represented as being connected to the positive
and negative terminals of the respective machines, but in many cases
where the load is subjected to sudden variations, and when a large
number of machines is connected to the bus bars, the shunt coils
are frequently connected direct to these. In such circumstances
this method is preferable, as by means of it the fields of the idle
dynamos can be excited almost at once direct from the bus bars by
the current from the working dynamos; hence, if a heavy load come on
suddenly, no time need be lost in building up a new machine previous
to switching it into parallel. The pressure of the lamp circuit is
given by a voltmeter whose terminals are placed across the bus bars;
and the pressure at the terminals of each of the machines is indicated
by separate voltmeters or pilot lamps, the terminals of which are
connected to those of the respective machines.
[Illustration: Fig. 687.--Diagram showing method of coupling shunt dynamos
in series. The ends of the shunt coils may be connected to the terminals
of their respective machine, or they may be connected in series as shown.]
Ques. Describe a better method of parallel connection.
Ans. Better results are obtained by connecting both the shunt coils in
series with one another, so that they form one long shunt between the two
main conductors, the same as in fig. 687.
When arranged in this way, the regulation of both machines may be
effected simultaneously by inserting a hand regulator (R) in series
with the shunt circuit as represented.
[Illustration: Fig. 688.--Diagram showing method of coupling shunt dynamos
in parallel.]
Switching Dynamo Into and Out of Parallel.--In order to put an additional
dynamo in parallel with those already working, it is necessary to run
the new dynamo up to full speed, and, when it excites, regulate the
pressure by means of a hand regulator until the voltmeter connected to
the terminals of the machines registers one or two volts more than the
voltmeter connected to the lamp circuit, and then close the switch. The
load upon the machine can then be adjusted to correspond with that upon
the other machines by means of the hand regulator.
Ques. In connecting a shunt dynamo to the bus bars, must the voltage be
carefully adjusted?
Ans. There is little danger in overloading the armature in making the
connection hence the pressure need not be accurately adjusted.
It is, in fact, common practice in central stations to judge the
voltage of the new dynamo merely by the appearance of its pilot lamp.
Ques. How is a machine cut out of the circuit?
Ans. When shutting down a machine, the load or current must first be
reduced, by gradually closing the stop valve of the engine, or inserting
resistance into the shunt circuit by means of the hand regulator; then
when the ammeter indicates nine or ten amperes, the main switch is opened,
and the engine stopped.
By following this plan, the heavy sparking at the switch contacts is
avoided, and the tendency for the engine to race, reduced.
Ques. What precaution must be taken in reducing the current?
Ans. Care must be taken not to reduce the current too much.
Ques. Why is this necessary?
Ans. There is danger that the machine may receive a reverse current from
the other dynamos, resulting in heavy sparking at the commutator, and in
the machine being driven as a motor.
Ques. What provision is made to obviate this danger?
Ans. Dynamos that are to be run in parallel are frequently provided with
automatic cutouts, set so as to automatically switch out the machine when
the current falls below a certain minimum value.
Dividing the Load.--If a plant, composed of shunt dynamos running in
parallel, be subjected to variations of load, gradual or instantaneous,
the dynamos will, if they all have similar characteristics, each take up
an equal share of the load. If, however, as is sometimes the case, the
characteristics of the dynamos be dissimilar, the load will not be shared
equally, the dynamos with the most drooping characteristics taking less
than their share with an increase of load, and more than their share
with a decrease of load. If the difference be slight, it may be readily
compensated by means of the hand regulator increasing or decreasing
the pressures of the machines, as the load varies. If, however, the
difference be considerable, and the fluctuations of load rapid, it becomes
practically impossible to evenly divide the load by this means.
Under such circumstances, the pressure at the bus bars is liable to
great variations, and there is also liability of blowing the fuses
of the overloaded dynamos, thus precipitating a general breakdown. To
cause an equal division of the load among all the dynamos, under such
circumstances, it is needful to insert a small resistance in the armature
circuits of such dynamos as possess the straightest characteristics, or
of such dynamos as take more than their share of an increase of load.
By suitably adjusting or proportioning the resistances, the pressures at
the terminals of all the machines may be made to vary equally under all
variations of load, and each of the machines will then take up its proper
share of the load.
Coupling Compound Dynamos in Series.--Since compound dynamos may be
regarded as a combination of the shunt and series wound machines, and
as no special difficulties are encountered in running these latter in
series, analogy at once leads to the conclusion that compound dynamos
under similar circumstances may be coupled together with equal facility.
Ques. How are compound dynamos connected to operate in series?
Ans. The series coils of each are connected as in fig. 685, and the shunt
coils are connected as a single shunt as in fig. 687, which may either
extend simply across the outer brushes of the machines, so as to form a
double short shunt, or may be a shunt to the bus bars of external circuit,
so as to form a double long shunt.
[Illustration: Fig. 689.--Coupling compound dynamos in series; short shunt
connection. The dotted lines indicate the changes that would be made for
long shunt connection.]
Compound Dynamos in Parallel.--Machines of this type will not run
satisfactorily together in parallel unless all the series coils are
connected together by an equalizing connection, as in series dynamos.
The method of arranging the connections as adopted in practice, being
illustrated in fig. 690. By means of it idle machines are completely
disconnected from those at work.
Ques. How is the equalizer connected?
Ans. The equalizer is connected direct to the positive brushes of all the
dynamos, a three pole switch being fitted for disconnecting it from the
circuit when the machine to which it is connected is not working. The
two contacts of the switch are respectively connected to the positive
and negative conductors, while the central contact is connected to the
equalizer.
[Illustration: Fig. 690.--Diagram showing method of coupling compound
dynamos in parallel.]
Switching a Compound Dynamo Into and Out of Parallel.--If the
characteristics of all the dynamos be similar, and the connections
arranged as in figs. 690, or 691, the only precaution to be observed in
switching a new machine into parallel is to have its voltage equal, or
nearly equal to that of the bus bars previous to closing the switch. If
this be the case, the new machine will take up its due share of the load
without any shock.
[Illustration: Fig. 691.--Diagram showing another and better method
of coupling compound dynamos in parallel. With this arrangement the
idle machines are completely disconnected from those at work. The same
reference letters are common in both diagrams. S, S' are switches; F,
F' fuses; A, A' ammeters, which indicate the total amount of current
generated by each of the machines; AC, AC', automatic switches, arranged
for automatically switching out a machine in the event of the pressure at
its terminals being reduced through any cause; R, R,' are hand regulators,
inserted in the shunt circuits of each of the machines, by means of which
the pressures of the individual machines may be varied and the load upon
each adjusted. The pressure at the bus bars is given by the voltmeter V,
one terminal of which is connected to each of the bars; a second voltmeter
may be used, to give the pressure of any individual machine, by connecting
"voltmeter keys" to the terminals of each of the machines, or a separate
voltmeter may be used for each individual machine. The only essential
difference between figs. 690 and 691 is, that in fig. 690 the equalizer
is connected direct to the positive brushes of all the dynamos, while
in fig. 691 the equalizer is brought up to the switchboard and arranged
between the two bus bars, a switch being fitted for disconnecting it from
the circuit when the machine to which it is connected is not working.]
Ques. How is a compound dynamo, running in parallel, cut out of circuit?
Ans. The load is first reduced to a few amperes, as in the case of shunt
dynamos, either by easing down the engine, or by cutting resistance into
the shunt circuit by means of the hand regulator, and then opening the
switch. Previous to this, however, it is advisable to increase the voltage
at the bus bars to a slight extent, as while slowing down the engine
the load upon the outgoing dynamo is transferred to the other dynamo
armatures, and the current in their series coils not being increased in
proportion, the voltage at the bus bars is consequently reduced somewhat.
Equalizing the Load.--When a number of compound dynamos of various output,
size, or make, are running together in parallel, it frequently happens
that all their characteristics are not exactly similar, and therefore the
load is unequally distributed, some being overloaded, while others do not
take up their proper share of the work.
NOTE.--The action of an equalizing bar in equalizing the load on
compound dynamos run in parallel may be explained as follows: The
compound winding of a dynamo raises the pressure in proportion to
the current flowing through it, and if, in a system of parallel
operated compound dynamos without the equalizing connection, the
current given by one machine were slightly greater than the currents
from the others, the pressure of that machine would increase. With
this increase in pressure above the other machines, a still greater
current would flow, and so raise the pressure further. The effect is
therefore cumulative, and in time the one dynamo would be carrying
too great a proportion of the whole current of the system. With the
equalizing connection, whatever the current flowing from each machine,
the currents in the various compound windings are all equal, and so
the added pressure due to the compound winding is practically the
same in each machine. Any inequality in output from the machines is
readily eliminated by adjusting the shunt currents by means of the
shunt rheostats. When compound wound dynamos are operated in parallel,
the equalizer bar insures uniform distribution among the series coils
of the machines.
NOTE.--To secure the best results in parallel operation, dynamos
should be of the same design and construction and should possess as
nearly as possible the same characteristics; that is, each should
respond with the same readiness, and to the same extent, to any change
in its field excitation. Any number of such machines may be operated
in parallel. The usual practice is to connect the equalizer and the
series field to the positive terminal, though if desired, they may be
connected to the negative terminal; both however, must be connected to
the same terminal. The resistance of the equalizer should be as low
as possible, and it must never be greater than the resistance of any
of the leads from the dynamos to the bus bar. Sometimes a third wire
is run to the switchboard from each dynamo and there connected to an
equalizer bar, but the usual practice is to run the equalizer directly
between the dynamos and to place the equalizer switches on pedestals
near the machines. This shortens the connections and leads to better
regulation. The positive and equalizer switches of each machine
differ in pressure only by the slight drop in the series coil, and in
some large stations these two switches are placed side by side on a
pedestal near the machine. In such cases, the equalizer and positive
bus bars are often placed under the floor near the machines, so that
all leads may be as short as possible. If all the dynamos be of equal
capacity, all the leads to bus bars should be of the same length, and
it is sometimes necessary to loop some of them.
If the difference be small, it may be compensated by means of the hand
regulator; if large, however, other means must be taken to cause the
machines to take up their due proportion of the load.
If the series coils of the several dynamos be provided with small
adjustable resistances, in the form of German silver or copper ribbon
inserted in series with the coils, the distribution of the current in the
latter may be altered by varying the resistance attached to the individual
coils. The effect of the series coils upon the individual armatures in
raising the pressure may be adjusted, and the load thus evenly divided
among the machines.
Shunt and Compound Dynamos in Parallel.--It is not practicable to run
a compound dynamo and a shunt dynamo in parallel, for, unless the field
rheostat of the shunt machine be adjusted continually, the compound dynamo
will take more than its share of the load.
CHAPTER XXXI
DYNAMO FAILS TO EXCITE
This trouble is of frequent occurrence in both old and new machines. If
a dynamo fail to excite, the operator should first see that the brushes
are in the proper position and making good contact, and that the external
circuit is open if the machine be shunt wound, and closed if series wound.
In starting a dynamo it should be remembered that shunt and compound
machines require an appreciable time to build up, hence, it is best not
to be too hasty in hunting for faults.
The principal causes which prevent a dynamo building up are:
1. Brushes not properly adjusted;
2. Defective contacts;
3. Incorrect adjustment of regulators;
4. Speed too low;
5. Insufficient residual magnetism;
6. Open circuits;
7. Short circuits;
a. In external circuits;
b. In dynamo.
8. Wrong connections;
9. Reversed field magnetism.
Brushes not Properly Adjusted.--If the brushes be not in or near their
correct positions, the whole of the voltage of the armature will not be
utilized, and will probably be insufficient to excite the machine. If in
doubt as to the correct positions, the brushes should be rotated by means
of the rocker into various points on the commutator, sufficient time being
given the machine to excite before moving them into a new position.
Defective Contacts.--If the different points of contact of the connections
of the machine be not kept thoroughly clean and free from oil, etc., it
is probable that enough resistance will be interposed in the path of the
exciting current to prevent the machine building or exciting. Each of the
contacts should therefore be examined, cleaned, and screwed up tight.
Ques. Which of the contacts should receive special attention?
Ans. The contact faces of the brushes and surface of the commutator. These
are very frequently covered with a slimy coating of oil and dirt, which
is quite sufficient to prevent the machine exciting.
Incorrect Adjustment of Regulators.--When shunt and compound machines
are provided with field regulators, it is possible that the resistance
in circuit may be too great to permit the necessary strength of exciting
current passing through the field windings. Accordingly, the fault is
corrected by cutting out more or less of the resistance. The field coils
of series machines are sometimes provided with short circuiting switches
or resistances arranged to shunt the current across the field coils. If
too much of the current be shunted across, the switch should be opened,
or if there be a regulator, it should be so adjusted that it will pass
enough current through the field windings to excite the machine.
Speed too Low.--In shunt and compound dynamos there is a certain critical
speed below which they will not excite. If the normal speed of the machine
be known, it can be seen whether the failure to excite arises from this
cause, by measuring the speed of the armature with a speed indicator. In
all cases it is advisable, if the machine do not excite in the course of a
few minutes, to slightly increase the speed. As soon as the voltage rises,
the speed may be reduced to its regular rate.
[Illustration: Fig. 692.--Method of testing for break by short circuiting
the terminals of the machine. If the external circuit test out apparently
all right, and there be no defective contacts in any part of the machine,
and all short circuiting switches, etc., be cut out of circuit, the
machine still refusing to excite, short circuiting the terminals of the
machine should be tried. This should be done very cautiously, especially
in case of a high tension machine. It is advisable to have, if possible,
only a portion of the load in circuit, and the short circuit should
be effected as shown in the figure. The short circuit may be made by
momentarily bridging across the two terminals of the machine with a single
piece of wire. As this, however, is liable to burn the terminals, a better
plan is to fix a short piece of scrap wire in one terminal, and then with
another piece of insulated wire make momentary contacts with the other
terminal and the short piece of wire. If the machine excite, it will be
at once evident by the arc which occurs between the two pieces of wire.
As the voltage of a series machine when induced to build in this manner
generally rises very rapidly, great care should be taken that the contact
is at first only momentary, merely a rubbing or scraping touch of the
wires. The contact may be prolonged if the machine do not excite at the
first contact. Compound wound machines can often be made to excite quickly
by short circuiting their terminals in this manner.]
Insufficient Residual Magnetism.--This fault is not of frequent
occurrence; it takes place chiefly when the dynamo is new, and may be
remedied by passing the current from a few storage cells, or from another
dynamo, for some time in the proper direction through the field coils.
If a heavy current, such as is obtainable from a storage battery, be not
available, and the machine be shunt or compound wound, a few primary cells
arranged as in fig. 693 will generally suffice.
[Illustration: Fig. 693.--Method of overcoming insufficient residual
magnetism. The flexible "lead" L of the dynamo D is disconnected from the
positive terminal of the machine, and is connected to the negative or zinc
pole of the battery B, the other or positive carbon pole being connected
to the terminal, from which the lead was removed, and shunt circuit S. As
thus arranged, it will be seen that the battery B is in series with the
armature and shunt circuit, and therefore its voltage will be added to any
small voltage generated in the armature. When the machine is started, the
combined voltages will probably be able to send sufficient current through
the shunt to excite the machine. As the voltage rises and the strength
of the current in the shunt windings increases, the flexible lead may be
again inserted into the terminal from which it was removed. The battery
will thus be short circuited, and may be cut out of circuit without any
danger of breaking the shunt circuit, and thus causing the machine to
demagnetize.]
Open Circuits.--Dynamos are affected by open circuits in different
ways, depending upon the type. Series machines require closed circuit to
build up, while an open circuit is necessary with the shunt machine. An
open circuit may be due to: 1, broken wire or faulty connection in the
machine; 2, brushes not in contact with commutator; 3, safety fuse blown
or removed; 4, circuit breaker open; 5, switch open; 6, external circuit
open. If the trouble be due merely to the switch or external circuit being
open, the magnetism of a shunt machine may be at full strength, and the
machine itself may be working perfectly, but if the trouble be in the
machine, the field magnetism will probably be very weak. Open circuits
are most likely to occur in:
1. The armature circuit;
2. The field circuit;
3. The external circuit.
When the open circuit is due to the brushes not making good contact,
simple examination generally reveals the fact.
Ques. What causes breaks in the field circuit?
Ans. Bad contacts at the terminals, broken connections, or fracture of
the coil windings.
Ques. How is the field circuit tested for breaks?
Ans. The flexible leads attached to the brushes are removed from their
connections with the field circuit, and the latter is then tested for
conductivity with a galvanometer.
Ques. Where is a break likely to occur in a shunt machine?
Ans. In the hand regulator through a broken resistance coil or bad contact.
Very frequently the fault occurs in the connecting wires leading
from the machine to the hand regulator fixed upon the switchboard,
or in the short wires connecting the field coils to the terminals or
brushes.
The insulation of a broken wire will sometimes hold the two ends
together so as to defy any but the most careful inspection or
examination; therefore, in order to avoid loss of time, it is
advisable to disconnect the wires if possible, and test each
separately for conductivity with a battery and galvanometer
connected, as in fig. 694. If the fault be not located in the various
connections, the magnet coils should be tested with the battery and
galvanometer coupled up as in fig. 706, care being first taken to
disconnect the ends of each of the coils. A faulty coil will not show
any deflection of the galvanometer.
[Illustration: Fig. 694.--Method of testing dynamo for short circuits.
In the figure, one pole of the battery B is placed in contact with the
frame of the machine at a point which has previously been well scraped and
cleaned; the other pole is connected to one of the galvanometer terminals
as shown. The other terminal of the galvanometer is connected to each of
the dynamo terminals T T under test in turn. If a deflection of the needle
be produced when the galvanometer terminal is in contact with either, the
terminals are in contact with the frame, and they should then be removed,
and the fault repaired by additional insulation or by reinsulating.]
Ques. At what point of a shunt coil does a break usually occur?
Ans. At the point where the wire passes through the flanges of the spool
or bobbin.
Ques. How should the coil be repaired?
Ans. In most cases a little of the wood or metal of which the flange is
made can be gouged or chipped out, and a new connecting wire soldered on
to the broken end of the coil without much difficulty.
If it be necessary to take the magnets apart at any time, care
should be taken in putting them together again to wipe all faces
perfectly clean, and screw up firmly into contact, and to see that
the connections of the coils are made as they were before being taken
apart.
If the faulty coil cannot be repaired quickly, and the machine is
urgently required, the coil may be cut out of circuit entirely, or
short circuited, and the remaining coils coupled up so as to produce
the correct polarity in the pole pieces.
[Illustration: Fig. 695.--Watson armature discs. Each lamination is made
from low carbon electrical steel of high magnetic permeability. Each disc
is annealed and afterwards varnished.]
Ques. What trouble is liable to be encountered in operating after cutting
out a coil?
Ans. The remaining coils are liable to heat up to a greater extent than
formerly, owing to the increased current, hence it is advisable to proceed
cautiously in starting the dynamo, since the temperature may exceed a safe
limit. If this occur, a resistance may be put in circuit with the field
coils, or the speed of the dynamo reduced.
[Illustration: Fig. 696.--Fort Wayne pedestal type commutator truing
device. When this device is used, the armature is revolved in its own
bearings by means of a handle clamped to the pulley. The tool has a
horizontal travel of 21 ins., (being 3 ins. wide inside the fastening
bolt in the base), and a vertical adjustment of 12 ins., adapting it to
machines with commutators up to 36 ins. in diameter.]
[Illustration: Fig. 697.--Fort Wayne yoke type commutator truing device
for machines having brush mechanism mounted on a yoke carried by the field
frame. It consists of a carriage for the tool holder having a screw feed
and a bracket for attaching to the brush yoke. The bracket replaces two
brush holder brackets on the brush yoke, and is made to fit the yoke of
the particular machine on which it is to be used.]
Ques. What kind of dynamo is affected by breaks in the external circuit?
Ans. A series dynamo.
Ques. Name the kind of break that is difficult to locate.
Ans. A partial break.
Short Circuits.--In a series or compound dynamo a short circuit or heavy
load will overload the machine and cause the fuses to blow. A shunt
machine will not excite under these circumstances, for the reason that
practically the whole of the current generated in the armature passes
direct to the external circuit, and the difference of potential between
the shunt terminals is practically nil.
Ques. What should be done if it be suspected that the failure to excite
arises from this cause?
Ans. The main leads should be taken out of the dynamo terminals, then, if
due to this cause, the machine will excite.
Ques. What parts of a dynamo are specially liable to be short circuited?
Ans. The terminals, brush holders, commutator, armature coils and field
coils.
Ques. How are the terminals liable to be short circuited?
Ans. The terminals of the various circuits of the machine are liable
to be short circuited, either through metallic dust bridging across the
insulation, or through the terminals making direct contact with the frame
of the machine.
The various terminals should be examined, and if the fault cannot be
located by inspection, they should each be disconnected from their
circuits and tested with a battery and galvanometer arranged as in
fig. 694.
Ques. What precaution should be taken with the brush holders?
Ans. Since, they are liable to be short circuited through the rocker
by metallic dust lodging in the insulating washers, they should be kept
clean.
Ques. How are the brush holders tested?
Ans. A galvanometer and battery are connected in series with one terminal
of the galvanometer connected to one set of brushes; the unconnected
terminal of the battery is then connected with the other set of brushes.
A deflection of the needle will indicate a short circuit.
[Illustration: Fig. 698.--Field coil testing with telephone receiver.
In the method here shown, a telephone receiver is connected in series
with two symmetrically placed coils A and B. Very little sound will
be heard when the flux through the two coils AB is the same; but if a
short-circuited coil is being tested, the fluxes through the coils A, B
will not be equal and a noise can be heard in the receiver.]
Ques. What is the effect of a short circuit in the field coils or field
circuit?
Ans. The machine generally refuses to excite.
Ques. How are the field coils tested for short circuit?
Ans. By measuring the resistance of each coil with an ohmmeter or
Wheatstone bridge. The faulty coils will show a much less resistance than
the perfect coils. The fault may also be discovered and located by passing
a strong current from a battery or another dynamo through each of the
coils in turn, and observing the relative magnetic effects produced by
each upon a bar of iron held in their vicinity.
The short circuit may be in the terminals or connections, and these
should first be examined and tested.
Some series dynamos are provided with a resistance, arranged in
parallel or shunt with the field coils, to divert a portion of the
current therefrom, and thus regulate the output.
When making a series dynamo excite, all resistances and controlling
devices should be temporarily cut out of circuit by opening the shunt
circuit. Series machines have frequently a switch which short circuits
the field coils. Care should be taken that this is open, or otherwise
the machine will not excite.
[Illustration: Fig. 699.--Watson armature complete. The armature coils
are form wound, heavily insulated and so mounted on the core as to insure
rapid dissipation of heat by ventilation. Each coil is protected by an
insulating sheath and tape covering before mounting. The armature is baked
after the coils are mounted to drive out all moisture, then, while hot,
is treated with insulating compound and again baked twelve hours.]
Wrong Connections.--When a machine is first erected, the failure to build
up may be due to incorrect connections. The whole of these latter should
therefore be traced or followed out, and compared with the diagrams of
dynamo connections given in figs. 190 to 198.
Sometimes errors are made in connecting the field coils, causing them
to act in opposition. This may occur when the dynamo is a new one
or the coils have been removed for repairs. It may be caused either
through the coils having been put on the field cores the wrong way,
or through incorrect coupling up. Under these circumstances, the
dynamo, if bipolar, will fail to excite; and if multipolar, poles
will be produced in the yokes, etc. It may be remedied by removing
one of the coils from the core and putting it on the reverse way, or
by reversing its connections. The correctness of connections of all
the coils should be verified.
In compound dynamos it sometimes happens that the machine will excite
properly, but that the series coils tend to reverse the polarity of
the dynamo, thus reducing the voltage as the load upon the machine
increases. This may be detected when the machine is loaded by short
circuiting the _series coils_, not the _terminals_. If the voltage
rise in doing this, the series coils are acting in opposition to
the shunt coils, and the connections of the _series coils_ must be
reversed.
Reversed Field Magnetism.--This is sometimes caused by the nearness
of other dynamos, but is generally due to reversed connections of the
field coils. Under such conditions the field coils tend to produce a
polarity opposed to the magnetization to which they owe their current, and
therefore the machine will refuse to excite until the field connections
are reversed, or a current is sent from another dynamo or a battery
through the field coils in a direction to produce the correct polarity in
the pole pieces.
CHAPTER XXXII
ARMATURE TROUBLES
A large proportion of the mishaps and breakdowns which occur with dynamos
and motors arise from causes more strictly within the province of the man
in charge than in that of the designer. The armature, being a complex and
delicately built structure, is subject in operation to various detrimental
influences giving rise to faults.
Many of the faults which occur are avoided by operators better informed as
to the electric and magnetic conditions which obtain in the running of the
machine, especially the mechanical stresses on the copper inductors due
to the magnetic field and the necessity of preserving proper insulation.
The chief mishaps to which armatures are subject are as follows:
1. Short circuits;
a. In individual coils;
b. Between adjacent coils;
c. Through frame or core;
d. Between sections of armature;
e. Partial short circuits.
2. Grounds;
3. Breaks in armature circuit.
Short Circuit in Individual Coils.--This is a common fault, which makes
its presence known by a violent heating of the armature, flashing at the
commutator, flickering of the light on lighting circuits, and by a smell
of burning varnish or overheated insulation. When these indications are
present, the machine should be stopped at once, otherwise the armature is
liable to be burnt out. The fault is due either to metallic dust lodging
in the insulation between adjacent bars of the commutator, or to one or
more convolutions of the coils coming into contact with each other, either
through a metallic filing becoming embedded in the insulation or damage
to the insulation.
[Illustration: Fig. 700.--Method of locating short circuited armature
coil. Disconnect the external and field circuits from the armature, and
pass a large current--say from 20 to 100 amperes--from a battery (B) or
another dynamo through the whole armature by means of the brushes. Then,
having previously well cleaned the commutator, measure the difference of
potential between adjacent segments all round the commutator (C), by means
of a voltmeter or galvanometer (G), the terminals of which are connected
to adjacent segments, as shown. The short circuited coil or coils will
be located by the difference of potential between the corresponding
segments being little or nothing. It may be remarked, however, that this
is not always a decisive test. In some cases the short circuit may be
intermittent, or may disappear as soon as the armature ceases to rotate.
In such cases, the short circuit is caused by the wire coming into contact
through the action of the centrifugal forces developed by the rotation of
the armature.]
Ques. How is the faulty coil located?
Ans. When the machine is stopped, the faulty coil, if not burnt out, can
generally be located by the baked appearance of the varnish or insulation,
and by its excessive temperature over the rest of the coils, being
detected also by the baked appearance of the varnish or insulation.
Ques. What should be done if the machine do not build, and it be suspected
that the fault is due to short circuited armature coils?
Ans. The field magnets should be excited by the current from a storage
battery or another dynamo, and, having raised the brushes from contact
with the commutator, the armature should be run for a short time. In
stopping, the faulty coil or coils may be located by the heat generated
by the short circuit.
When the dynamo is started for the purpose of localizing a short
circuit, precautions should be taken, and the machine only run for a
few minutes at a time until the faulty coil is detected.
When the faulty coil has been located, the insulation between the
segments of the commutator to which its ends are connected should be
carefully examined for anything that may bridge across from segment
to segment, and scraped clean. If the commutator be apparently all
right, the fault probably lies in the winding. The insulation of the
winding should be carefully examined, and any metallic filings or
other particles discovered therein carefully removed, and a little
shellac varnish applied to the faulty part.
[Illustration: Fig. 701.--Test for break in armature lead. Clean the
brushes and commutator, and apply current from a few cells of battery
having a telephone receiver in circuit as shown in the figure. If the
machine have more than two brushes, connect the leads to two adjoining
brushes and raise the others. Now rotate the armature slowly by hand and
there will be a distinct click in the receiver as each segment passes
under the brushes until one brush bears on the segment at fault, when the
clicking will cease. In making this test, the brushes must not cover more
than a single segment.]
Ques. If the insulation on adjacent conductors has been abraded, how
should it be repaired?
Ans. A small boxwood or other hardwood wedge, coated with shellac varnish
should be driven in tightly between the wire; this will generally be
sufficient.
[Illustration: Fig. 702.--Bar to bar test for open circuit in coil or
short circuit in one coil or between segments. If, in testing as in fig.
701, on rotating the armature completely around, the receiver indicate no
break in the leads, connect the battery leads directly to the brushes, as
shown in the above figure, and touch the connections from the receiver
to two adjacent bars, working from bar to bar. The clicking should be
substantially the same between any two commutator bars; if the clicking
suddenly rise in tone between two bars, it indicates a high resistance in
the coil or a break (open circuit).]
Ques. If a faulty coil cannot be quickly repaired and the dynamo be
needed, what should be done?
Ans. The coil may be cut out of circuit, and the corresponding commutator
segments connected together with a piece of wire (of a size proportionate
to the amount of current to be carried), soldered to each. It will not be
necessary to cut out and remove the entire coil.
If the active portions only be separated so that they do not form a
closed circuit, it will answer the purpose. If the wires be cut with
a chisel at the point where they pass over the ends of the core, and
the ends separated, it will be quite as effective as removing the
entire coil. It is wise, of course, to rewind the coil at the first
opportunity.
[Illustration: Fig. 703.--Alternate bar test for short circuit between
sections. Where two adjacent commutator bars are in contact, or a
coil between two segments becomes short circuited, the bar to bar test
described in fig. 702 will detect the fault by the telephone receiver
remaining silent. If a short circuit be found, the leads from the receiver
should then include or straddle three commutator bars, as here shown. The
normal click will then be twice that between two segments until the faulty
coils are reached, when the clicking will be less. When this happens,
test each coil for trouble and, if individually they be all right, the
trouble is between the two. To test for a ground place one terminal of
the receiver on the shaft or frame of the machine, and the other on the
commutator. If there be a click it indicates a ground. Move the terminal
about the commutator until the least clicking is heard and at or near that
point will be found the contact. Grounds in field coils can be located in
the same manner.]
Short Circuits between Adjacent Coils.--In ring armatures the presence of
this fault does not necessarily imply that the machine will not build;
in drum armatures, wound into a single layer of conductors, it entirely
prevents this occurring.
Reference to a winding diagram will show that adjacent coils are during
a certain period of the revolution at the full difference of pressure
generated by the machine. Hence, if any two adjacent coils be connected
together or short circuited, the whole of the armature will be practically
closed on itself, any current generated flowing within the armature only.
Large drum armatures wound with compressed and stranded bars and
connectors are particularly susceptible to this fault, a slight blow
generally forcing one or more of the strands into contact with the
adjacent bars, thus short circuiting the armature, and rendering it
practically useless so far as the generation of current is concerned.
In this class of short circuit in drum armatures, the method of locating
the faulty coils by exciting the field, and running the armatures on open
circuit, does not apply, for the reason that the whole armature will be
heated equally.
A method of locating such fault is illustrated in fig. 704. This
applies to drum wound armatures. Faults of this description can
frequently be discovered by a careful inspection of the windings of
the armature without recourse to testing. When located, the fault
can usually be repaired with a hardwood wedge, as explained above,
or a piece of mica or vulcanized fibre cemented in place with shellac
varnish.
[Illustration: Fig. 704.--Method of locating short circuits between
adjacent armature coils. Fasten a monkey wrench to the rim of the pulley,
or a crank to the shaft. Now, excite the fields, and, to make the effects
more marked, connect the coils in parallel. When this has been done it
will require considerable force to rotate the armature, and then it will
move quite slowly, except at one position. When this position has been
found, mark the armature at points in the center of the pole pieces at
points A and B and at both ends of the armature. The explanation is that
both halves of the armature oppose one another at this position; but when
not at these points a continuous circuit is formed, and the resultant
magnetic effect is considerable. The "cross" or "short" circuit is nearly
always found on the commutator end in the last half of the winding, where
the wires pass down through the first half terminals. This applies to
an unequal winding. In armatures where the windings are equal, it is as
liable to occur at one point as at another. With this method a defect can
be found and remedied in a few moments, for it has always been a simple
matter to repair it when discovered. These results can be observed in a
perfect armature by connecting the opposite sections of the commutator.]
Short Circuits between Sections through Frame or Core of
Armature.--Detection of this fault can be effected by the methods
described above, and by disconnecting the whole of the armature coils
from the commutator and from each other, and testing each separately
with a battery and galvanometer coupled up as in fig. 705, one wire being
connected to the shaft and the other to the end of the coil under test.
As a rule, there is no way of remedying this fault other than unwinding
the defective coils, reinsulating the core, and rewinding new coils.
[Illustration: Fig. 705.--Method of locating short circuits between coils
through armature core. The galvanometer, battery and coil to be tested
are connected in series as shown, and then the unconnected terminal of the
galvanometer is brought into contact with the shaft. If then some portion
of the insulation of the wire has been abraded or destroyed, thus bringing
the bare wire into contact with the metal core, as at A in the figure,
the needle of the galvanometer will be deflected since a closed circuit is
formed through the core and wire. If the insulation be perfect, the needle
will not be deflected. It will thus be seen that in the conductivity test
(fig. 700) it is necessary that the needle should be deflected, or turned,
to prove that all is right, while in the insulation test the converse
holds good; if the needle be deflected, it proves that the insulation is
broken down.]
Short Circuits between Sections through Binding Wires.--This fault is
the result of a loose winding, and is caused by the insulation upon which
the binding wires are wound giving way, thus bringing coils at different
pressures together. As a consequence of the heavy current which flows,
the binding wires are as a rule unsoldered or burned. The location of the
fault can therefore be effected by simple inspection. To remedy, it will
be necessary to unwind and rewind on new binding wires, on bands of mica
or vulcanized fibre, soldering at intervals to obviate flying asunder.
Partial Short Circuits in Armatures.--This is usually due to the presence
of moisture in the windings. To remedy the fault, the armature should be
taken out and exposed to a moderate heat, or subjected to a current equal
to that ordinarily given by the dynamo. Under the action of heat or of
this current the moisture will be gradually dispersed. When thoroughly
dry, and while still warm, a coat of shellac should be applied to the
whole of the windings.
[Illustration: Fig. 706.--Method of testing for breaks. The instruments
are connected as shown. B is the battery, G the galvanometer, and S the
coil of wire being tested. One terminal of the battery is connected to a
terminal of the galvanometer, and the other to one of the ends of the coil
under test. The other terminal of the galvanometer is connected to the
other end of the coil. If the connecting wires be making good electrical
contact with the respective terminals, and the wire of coil being tested
be unbroken, the needle of the galvanometer will be deflected as soon
as a closed circuit is made by the end of the coil coming into contact
with the galvanometer terminal. If the wire of the coil be broken in some
part or the ends of the connecting wires do not make good electrical
contact with the terminals, the needle will not be deflected. In order
to prevent mistakes, it is advisable to test the battery and galvanometer
connections and contacts by short circuiting or bringing the ends of the
wire connecting the terminal of the galvanometer and negative pole or
the battery together before starting to test the circuit or coil. If the
needle be deflected, the connections are all right; if not deflected,
there is a bad contact somewhere, which must be made good before the test
can proceed.]
Burning of Armature Coils.--The reason for the burning of an armature
coil may be explained as follows: The coil, segments, and the short
circuit between the segments form a closed circuit of low resistance so
that it is only necessary to have a low pressure set up in the active
portion of the coil to force a very large current through the coil and
the short circuited commutator bars. The heating effect of this current
is sufficient to burn out the coil.
[Illustration: Fig. 707.--Watson field coils. Automatic machinery is
employed to wind these coils; after winding, they are bound with tape,
then baked to expel all moisture, and while hot, are saturated with
an insulating compound and again baked for twelve hours to make them
practically oil and water proof. Heavy flexible leads are brought out to
avoid danger of breaking or other damage.]
Cutting Out Damaged Armature Coils.--To cut out a damaged coil from
an armature, first, disconnect the coil from the commutator, and after
cutting off the leads, insulate the exposed parts with tape. Then connect
the commutator bars (which were connected with the leads) with a wire of
the same size as the wire winding.
To remove the coil entirely, cut the band wire or remove the wedges, and
lift up a sufficient number of leads and coils to permit of the removal
of the damaged coil.
Grounds in Armatures.--These faults occur when the armature coils become
connected to the frame or core of the armature. When this grounding is
confined to a single coil, it is not in itself liable to do damage. A
simple method of locating a grounded coil is illustrated in fig. 708.
[Illustration: Fig. 708.--Method of locating grounded armature coil. B
is a battery or dynamo circuit giving a current of a few amperes through
the armature by its own brushes (1 and 2). At G is placed a roughly
made galvanometer, to carry some 25 amperes or so, one terminal being
in connection with the shaft of the armature, and the other attached to
a movable brush 3. Since the function of the particular galvanometer is
simply to show a deflection when a current is passing, and to mark zero
when there is none, a coil of thick wire with a pocket compass in the
center will do all that is required, but care must be taken to remove
it sufficiently far away from the disturbing effects of the armature
magnetism. The manner of testing is as follows: Assume a steady current to
be flowing from battery B through the armature; touch the commutator with
brush 3, and a current will flow through G. Slowly rotate the armature
or the brush 3 until the galvanometer G shows no deflection. The coil
in contact with 3 will be found to be _grounded_. A hand regulator or
rheostat R may be inserted in series with the battery or dynamo circuit
to regulate the strength of the current passing.]
Ques. What is the advantage of this test?
Ans. The damaged coil can be located without unsoldering the coils from
the commutator, which is sometimes a difficult operation without proper
tools; further, the fault can frequently be repaired without disconnecting
any of the wires if its exact position be determined.
Magneto Test for Grounded Armatures.--A magneto test for grounded
armatures is not to be recommended, as armatures often possess sufficient
static capacity to cause a magneto to ring even though there be no leak.
This is due to the alternating current given by the magneto for when the
circuit has capacity it acts as a condenser and at each revolution of the
armature of the magneto a rush of current goes out and returns, charging
the surfaces of the conductor alternately in opposite directions, and
ringing the bell during the process.
[Illustration: Fig. 709.--Method of binding armature winding. Complete
appliances for handling armatures in making repairs are usually not
available with most street railway companies, since they are so seldom
required. When needed, therefore, some temporary contrivance must be
resorted to for help in the dilemma. Should an armature burn out, some
local concern that makes coils and rewinds armatures may be available to
do the work; again, it will be necessary to send to the manufacturers for
a man, as soon as coils can be made ready for the work. In no case should
any but an experienced man be given charge of this work. But if there be
any doubt as to whether the armature is really burnt out, let a competent
man be the judge. When a large armature needs repairing, a pair of chain
tongs can be used on some part of the shaft when putting in the coils,
and a block and tackle, as shown, can be used, when putting on the band
wires. Do not finish one band and then cut off the wire, but run it over
for the next, etc. Then solder and trim off the wires.]
Breaks in Armature Circuit.--A partial or complete break in the armature
circuit is always accompanied by heavy sparking at the commutator, but
not, as a rule, by an excessive heating of the armature or slipping of
the belt, and this enables the fault to be distinguished from a short
circuit. The faulty part can always be readily located by the "flat" which
it produces upon the surface of the commutator. The armature circuit being
open at the faulty part, heavy sparking results at every half revolution
as the brushes pass over it, and as a consequence the corresponding
segments become "pitted" or "flattened" with respect to the others; they
may easily be discovered on examination.
Breaks in the armature circuit may occur in either the commutator
or in the coils of the armature. To ascertain whether it be in the
latter, carefully examine the winding of the faulty coil.
The defect may be sought for more particularly at the commutator end
of the armature, as breaks in the wire are most frequent where the
connections are made with the commutator segments. If no break can
be discovered, try passing a heavy current through the faulty coil by
means of the brushes.
If a partial break exist with sufficient contact to pass a current,
the coil will be heated at that point and may be discovered by running
the fingers over the coil.
When located, the fault may be repaired by rewinding the coil, or
carefully cleaning the broken ends and jointing.
The fault may also be temporarily repaired by soldering the adjacent
commutator segments together without disconnecting the coil.
CHAPTER XXXIII
CARE OF THE COMMUTATOR AND BRUSHES
For satisfactory operation, the brushes and commutator must be kept
in good condition. To this end the main thing to be guarded against is
the production of sparks at the brushes. If care be taken in the first
instance to adjust the brushes to their setting marks, and to regulate
their pressure upon the commutator, and afterwards to attend to the lead
as the load varies, so that little or no sparking occurs, and also to keep
the brushes and commutator free from dirt, grit, excessive oil, etc., the
surface of the commutator will assume a dark burnished appearance and wear
will practically cease. Under these circumstances the commutator will run
cool, and will give very little trouble.
In order to maintain these conditions it will only be necessary to see
that the brushes are kept in proper condition and fed forward to their
setting marks, as they wear away, and that the commutator is occasionally
polished.
If the pressure of the brushes upon the commutator be too great, or
their adjustment faulty, or the commutator be allowed to get into a
dirty condition, sparking will result, and, if not at once attended to
and remedied, the brushes will quickly wear away, and the surface of the
commutator will be destroyed. As this action takes place, in the earlier
stages, the surface of the commutator will become roughened or scored,
resulting in jumping of the brushes, and increased sparking; in the later
stages, the commutator will become untrue and worn into ruts, moreover,
owing to the violent sparking which takes place through this circumstance,
the machine will quickly be rendered useless[D].
[D] NOTE.--In operating dynamos having metal brushes, it is of importance
to keep the commutator smooth and glossy. To accomplish this, it is
necessary to keep the commutator and brushes clean and free from grit,
and to occasionally lubricate the commutator with some light oil, such
as ordinary machine oil. This should be done daily if the machine be
in constant use. Keep the brushes resting upon the commutator with just
enough pressure to insure a good firm contact. This will be found to be
much less than the springs are capable of exerting. A good method to
follow in cleaning the machine is as follows: Loosen the brush holder
thumb screws and tilt the brushes off the commutator (or, if box brush
holders be used, take them out of their holders). Then run the machine and
hold a clean cloth against the commutator. After the commutator is clean,
hold against it a cloth or piece of waste moistened with machine oil and
reset the brushes. If for any reason the brushes begin to cut or score
the commutator, it may be readily detected by holding the finger against
the commutator; the ridge may be easily felt by the finger. This should
be attended to at once in the following manner: Tilt back the brushes (or
if box brushes are used take them out of their holders), and hold lightly
against the commutator a piece of No. 00 sandpaper well moistened with
oil, passing it back and forth until the surface is perfectly smooth. Then
wipe off the commutator with a clean piece of cloth or waste and lubricate
with another clean piece moistened with oil and reset the brushes.
Ques. How is the commutator easily tested as to the condition of its
surface?
Ans. It is readily tested by resting the back of the finger nail upon
it while in motion; the nail being very sensitive to any irregularities,
indicates at once any defect.
Ques. What causes grooves or ridges to be cut in the commutator?
Ans. They result from using brushes with hard burnt ends which are not
pliable; also by too great a pressure of the brush upon the commutator
surface.
Sparking at the brushes is expensive and detrimental, chiefly
because it results in burning the brushes and also the commutator,
necessitating their frequent renewal. Every spark consumes a particle
of copper, torn from the commutator or brush. The longer the sparking
continues, the greater the evil becomes, and the remedy must be
applied without delay.
Ques. What kind of oil should be used on the commutator?
Ans. Mineral oil.
Ques. What attention should be given to the brushes?
Ans. At certain intervals, according to the care taken to reduce sparking
and the length of time the machine runs, the brushes will fray out or wear
unevenly, and will therefore need trimming. They should then be removed
from the brush holders and their contact ends or faces examined. If not
truly square, they should be filed or clipped with a pair of shears, the
course of treatment differing with the type of brush.
If the machine be fitted with metal strip brushes, frayed ends should
be clipped square with a pair of shears, the ends thoroughly cleaned
from any dirt or carbonized oil, and replaced in their holders. Gauze
and wire brushes require a little more attention. When their position
on the commutator has been well adjusted and looked after, so that
little or no sparking has taken place, it is generally only necessary
to wipe them, clean the brushes and clip off the fringed edges and
corners with the shears, or a pair of strong scissors. If, however,
the machine has been sparking, the faces will be worn or burnt away,
and probably fused. If such be the case, they will need to be put in
the filing clamp, and filed true.
A convenient method of trimming carbon brushes, or of bedding a
complete new set of metal brushes, is to bind a piece of sandpaper,
face outwards, around the commutator after the current has been
shut off, and then mount the carbon or metal brushes in the holders,
adjusting the tension of the springs so that the brushes bear with a
moderately strong pressure upon the sandpaper. Then let the machine
run slowly until the ends of the brushes are ground to the proper
form. Care should be taken, however, that the metal dust given off
does not get into the commutator connections or armature windings, or
short circuiting will result.
If the contact faces of the brushes are very dirty and covered with
a coating of carbonized oil, etc., it will be necessary to clean them
with benzoline or soda solution before replacing.
[Illustration: Fig. 710.--Bissell brush gear. The brushes are held in
the brushholders radially and work equally well with armature running in
either direction. Brushes can be renewed and adjustment made while machine
is in operation.]
Ques. Describe a filing clamp.
Ans. As usually constructed, it consists of two pieces of metal, both
shaped at one end to the correct angle, to which the brushes must
be filed. One of the pieces of metal (the back part) has a groove
sufficiently large to accommodate the brush, which is clamped in position
by the other piece of metal and a pinching screw.
If the clamp be not supplied with the machine a convenient substitute
can be made out of two pieces of wood about the same width as the
brush. One end of each piece is sawn to the correct angle, and the
brush placed between the two.
In filing, the brush is fixed in the clamp, with the toe or tip
projecting slightly over the edge of the clamp, and the latter being
fixed in a vise, the brush is filed by single strokes of a smooth file
made outwards, the file being raised from contact with the brush when
making the back stroke.
[Illustration: Fig. 711.--Jig for filing brushes to the correct bevel;
used with copper brushes to fit them to the commutator.]
Sparking.--In all well designed machines there are certain positions upon
the commutator for the brushes at which there will be no sparking so long
as the commutator is kept clean and in good condition. In other dynamos,
badly designed or constructed, sparking occurs at all positions, no
matter where the brushes are placed, and in such dynamos it is therefore
impossible to prevent this no matter how well they are adjusted.
[Illustration: Fig. 712.--Commutator clamp; a useful device for holding
the segments firmly in position in taking out the end rings of the
commutator to repair for internal grounds. It is made of 2 × 1/8 inch
sheet steel, with a 1/2 inch screw. The illustration clearly shows the
adjustable fastening. The notches fit around rivets on one side of each
fastening, which can be moved by removing the two cotters. The clamp is
made loose or taut by screwing the bolt in the nut.]
Ques. What two kinds of sparking may be generally distinguished?
Ans. One kind of sparking is that due to bad adjustment of the brushes,
and a second kind, that due to bad condition of the commutator.
Sparks due to bad adjustment of the brushes are generally of a bluish
color, small when near the neutral plane, and increasing in violence
and brilliancy as the brushes recede from the correct positions upon
the commutator.
When sparks are produced by dirty or neglected state of the
commutator, they are distinguished by a reddish color and a
spluttering or hissing. When due to this last mentioned cause, it is
impossible to suppress the sparking until the commutator and brushes
have been cleaned. In the former case, the sparks will disappear as
soon as the brushes have been rotated into the neutral points.
Another class of sparks appear when there is some more or less
developed fault, such as a short circuit, or break in the armature or
commutator. These are similar in character to those produced by bad
adjustment of the brushes, but are distinguished from the latter by
their not decreasing in violence when the brushes are rotated towards
the neutral plane.
Having distinguished the classes of sparks which appear at the commutator
of a dynamo, it remains to enumerate the causes which produce them. These
are:
1. Bad adjustment of brushes;
2. Bad condition of brushes;
3. Bad condition of commutator;
4. Overload of dynamo;
5. Loose connections, terminals, etc.;
6. Breaks in armature circuit;
7. Short circuits in armature circuit;
8. Short circuits or breaks in field magnet circuit.
Bad Adjustment of Brushes.--When sparking is produced by bad adjustment
of the brushes, it may be detected by rotating or shifting the rocker, by
the indication that the sparking will vary with each movement.
To obtain good adjustment of the brushes, it will be necessary to rock
them gently backwards and forwards, until a position is found in which
the sparking disappears.
Ques. If, in rocking the brushes, a position cannot be found at which the
sparking disappears, what is the probable cause of the trouble?
Ans. The brushes may not be set with the proper pitch, that is they may
not be separated a correct distance, or the neutral plane may not be
situated in the true theoretical position upon the commutator through some
defect in the winding, etc.
In this last named case, the brushes may be strictly adjusted to their
theoretically correct positions before starting the machine; then,
when the machine is started and the load put on, violent sparking
occurs, which cannot be suppressed by shifting the rocker. If,
however, one set of brushes only be observed, it will generally be
found that, at a certain position, the sparking at the set of brushes
under observation ceases or is greatly reduced, while sparking still
occurs at the other set. When this position is found, the rocker
should be fixed by the clamping screw, and the brushes of the other
set at which sparking is still occurring adjusted by drawing them back
or pushing them forward in their holders until a position is found
at which the sparking ceases. Correct position of the brushes and
the suppression of sparking is a matter of importance, and any time
spent in carefully adjusting the brushes will be amply repaid by the
decreased attention and wear of the brushes and commutator.
[Illustration: Figs. 713 to 715.--Brushes making bad contact. A brush
making a bad contact, as only at the shaded portion of figs. 713 and 714,
will not allow the short circuited coil enough time to reverse, causing
sparking and heating. The latter will also result from bad contact on
account of the surface being too small for the current to be carried off.
This form of bad contact is worse than that shown in fig. 715, where the
area of contact surface only is lessened. If the brushes do not make good
contact, they should be ground down.]
Bad Condition of Brushes.--If the contact faces of the brushes be fused or
covered with carbonized oil, dirt, etc., there will be bad contact which
is accompanied by heating and sparking. Simple examination will generally
reveal whether this be the case. The remedy is to remove the brushes, one
at a time if the machine be running, clean, file if necessary, trim, and
readjust.
If the brushes be exceedingly dirty, or saturated with oil, it will be
necessary to clean them with turpentine, benzoline, or soda solution,
before replacing.
Bad Condition of Commutator.--If the surface of the commutator be rough,
worn into grooves, or eccentric, or if there be one or more segments
loose or set irregularly, the brushes will be thrown into vibration,
and sparking will result. A simple examination of the commutator will
readily detect these defects. A rough and uneven commutator is due to bad
adjustment of brushes, bad construction of commutator, and to neglect
generally. If allowed to continue, it results in heavy sparking at the
brushes, and the eventful destruction of the commutator. The fault may be
remedied by filing or re-turning the commutator.
[Illustration: Fig. 716.--Rough and grooved commutator due to improper
brush adjustment and failure to keep brushes in proper condition.]
Ques. How is an untrue commutator detected?
Ans. If the commutator be untrue, the fact will be indicated when the
machine is slowed down by a visible eccentricity, or by holding the hand,
or a stick in the case of a high tension machine, against the surface
while revolving, when any irregularity or eccentricity will be apparent
by the vibration or movement of the stick. The only remedy for an untrue
commutator is to re-turn it in the lathe.
Ques. What should be done in case of high segments?
Ans. They should be gently tapped down with a mallet, and if possible the
clamping cones at the commutator end should be tightened.
If it be impossible to hammer the segments down, they should be
filed down to the same diameter as the rest of the commutator, or the
commutator re-turned. For low segments, the only remedy is to pull
out the segments, or turn commutator down to their level.
Ques. Explain the term "flats on the commutator."
Ans. This is the name given to a peculiar fault which develops on one or
more segments of the commutator. It is not confined to dynamos of bad
design or construction, but frequently appears on those of the highest
class, and may be recognized as a "pitting" or "flattening" of one or more
segments.
Ques. What is the effect of flats on the commutator?
Ans. Sparking at the brushes.
Ques. What are the causes which produce flats?
Ans. Periodical jumping of the brushes due to a bad state of the
commutator, bad joint in the driving belt, a flaw, or a difference in the
composition of the metal of the particular bar upon which it appears. But
more frequently flats may be traced to a more or less developed fault,
such as a break, either partial or complete, in the armature coil.
The break may occur either in the coil itself, or at the point where
its ends make connection with the lug of the commutator, or at the
point where the lug is soldered to the segment.
Ques. What should be done in case of flats?
Ans. The brushes should be examined to see if any periodical vibration
take place. If such be the case, the cause should be removed, the flat
carefully filed or turned out, and the brushes readjusted.
If it be due to a difference in the composition of the metal of which
the segment is made, the flat will exist as long as the particular
segment is in use, and will need periodic attention.
With hard drawn copper or phosphor bronze segments, this fault is
rarely due to this last mentioned cause. It is more frequently due to
bad soldering, of the conductors to the lugs, or of the lugs to the
segments. In all cases of flats, if the disconnection in the armature
circuit be not complete, and cannot be readily located, the effect of
re-soldering or sweating the ends of the coils into the lugs should
be tried. Flats may also frequently be cured by drilling and tapping
a small hole in the junction between the lug and the segment, and
inserting a small screw, or bit of screwed copper or brass wire,
afterwards filing down level with the surface of the commutator.
[Illustration: Figs. 717 and 718.--Method of repairing broken joint
between commutator segment and lug. To repair such a break push asbestos
in between adjacent bars, so that heat from the torch will not affect
them. Asbestos should also be worked in at the back if possible, for
the purpose of keeping solder from places where it would cause trouble.
Then unsolder the armature leads from the lug and remove the latter.
Next, with specially made cape chisels, cut in a slot in the commutator
bar for a new lug. Care and skill are required not to destroy the mica
insulation between the segments. The slot should be cut one-quarter to
three-eighths inch deep. The connector is then soldered in place. With
care a satisfactory connection can be made in this way, which will last
well. If it do not last, the trouble in almost every case is due to poor
soldering. Short circuits sometimes occur after this operation, because
of solder falling in at the back and lodging on lower connections. In
large machines, the excessive current flowing is quite likely to melt this
solder, and the machine may buck, throwing out the melted solder, after
which it may be all right again. While the bar connector is out, however,
asbestos should be packed in back of it to prevent this occurrence, which
may be a serious affair. All surplus solder and the asbestos packing
should be removed after the connection is finished, and the connections
cleaned with compressed air. The armature should be turned over slowly,
air being applied all the while.]
Segments Loose or Knocked In.--When the segments are loose, it is an
indication that the clamping ring or cone has worked loose. This should
therefore be tightened up, and the commutator re-turned if necessary.
Ques. How should low commutator segments be treated?
Ans. The commutator surface may be turned down to the level of the low
segment, or the latter may be pulled out again to its former level, this
latter being the preferable method, if it can possibly be effected.
Ques. How is a commutator segment pulled out to its correct position?
Ans. A hand vise is firmly clamped to the lug, or a loop of copper wire is
passed round the conductor where it joins the commutator. A bar of iron,
to act as a lever, is supported on a fulcrum over the commutator, and one
end of the bar is passed through the loop or vise. Pressure is applied
to the other end which will generally bury the segment up to its proper
position.
How to Re-turn a Commutator.--In re-turning the commutator, the armature
should first be carefully taken out of the armature chamber, avoiding
knocks or blows of any kind. The whole of the winding should then be
wrapped in calico or canvas before the armature is put into the lathe,
to prevent any particles of metal becoming attached to the surface of the
armature at the time the commutator is being turned. The armature should
on no account be rolled upon the floor, or subjected to blows or knocks
while being put into the lathe.
In re-turning the commutator, a sharp pointed tool should be used
with a very fine feed. A broad nosed tool ought not to be used, as
it is liable to burr over the segments. After turning, the commutator
should be lightly filed with a dead smooth file, and finally polished
with coarse and fine sandpaper. After the commutator has been turned
and polished, the insulation between the segments should be lightly
scraped with the tang of a small file to remove any particles of metal
or burrs which might short circuit the commutator.
The points where the armature wires are soldered to the lugs should
also be carefully cleaned with a brush, and should then receive a coat
or two of shellac varnish.
While the commutator is being turned, care should be taken that the
setting marks for the adjustment of the brushes are not turned out if
these be present. The same care should be used in putting the armature
back into the armature chamber as was used in taking it out, otherwise
the insulation may be damaged.
[Illustration: Figs. 719 and 720.--Bissell commutators. The segments are
of hard drawn copper and are insulated from each other and from the shell
by mica.]
Ques. Should the commutator be run without any lubricant?
Ans. In most cases it will be found that a little lubricant is needed
in order to prevent cutting the brushes, cutting the commutator; this is
especially the case when hard strip brushes are used. The quantity of oil
applied should be very small; a few drops smeared upon a piece of clean
rag, and applied to the commutator while running, being quite sufficient.
Ques. What kind of oil should be used on the commutator?
Ans. Mineral oil, such as vaseline, or any other hydrocarbon. Animal or
vegetable oils should be avoided, as they have a tendency to carbonize,
and thus cause short circuiting of the commutator, with attendant
sparking.
[Illustration: Figs. 721 to 723.--Method of repairing a large hole burned
in two adjacent bars of a commutator. Fig. 721 shows the hole. The first
operation is to clean carefully and tin the surface of the hole. The two
bars are then wedged apart and mica strips, A B, fig 722, of the requisite
size and thickness forced in. The commutator must now be warmed up as much
as possible by means of soldering irons, and strips of mica, C D, E F,
fig. 723, placed at the front and back of the hole, being kept in position
by pieces of wood W, solder is poured into the hole from a ladle, using
a rough mica funnel to guide it.]
Overload of Dynamo.--It may happen, through some cause or other that a
greater output is taken from the machine than it can safely carry. When
this is the case, the fact is indicated by excessive sparking at the
brushes, great heating of the armature and other parts of the dynamo, and
possibly by the slipping of the belt (if it be a belt driven machine),
resulting in a noise. The causes most likely to produce overload are:
1. Excessive voltage;
2. Excessive current;
3. Reversal of polarity of dynamo;
4. Short circuits or grounds in dynamo, or external circuits.
Ques. What is the indication of excessive voltage?
Ans. It is indicated by the voltmeter, or by the brilliancy of the pilot
lamp.
[Illustration: Fig. 724.--Method of smoothing commutator with a stone. The
proper stone to use is made out of white sandstone similar to that used
for grindstones, but a trifle softer. It is dove-tailed into a holder,
as shown in the illustration, and held in place by a set screw. When
being used, one knob is grasped in one hand and the other knob in the
other hand, the stone being moved back and forth along the length of the
commutator. As the stone will become coated with copper at first, it must
be cleaned frequently by means of coarse sandpaper. The fine dust from
the stone will get under the brushes and wear them to a very close fit.
After using the stone, finish with fine sandpaper.]
Ques. What are the causes of excessive voltage?
Ans. Over excitation of the field magnet or too high speed.
In the former case, resistance should be introduced into the field
circuit to diminish the current flowing therein if a shunt machine; or
if a series machine, a portion of the current should be shunted across
the field coils by means of a resistance arranged in parallel with
the series coils; or the same effect may be produced in both cases by
reducing the speed of the armature if this be possible.
If due to excessive speed, which will be indicated by a speed
indicator, the natural remedy is to reduce the speed of the engine
driving the dynamo, or, if this be not easily done, insert resistance
into the dynamo circuit, as described above.
Ques. What are the causes of excessive current?
Ans. If the dynamo be supplying arc lamps, the excessive current may
possibly be caused by the bad feeding of the lamps. If this be the case,
the fact will be indicated by the oscillations of the ammeter needle, and
the unsteadiness of the light.
If incandescent lamps be in the circuit, the fault may be caused
by there being more lamps in circuit than the dynamo is designed to
carry. Under such circumstances, another dynamo should be switched
into circuit in parallel, or, if this be not possible, lamps should
be switched off until the defect is remedied.
When motors are in the circuit, sparking frequently results at the
dynamo commutator, owing to the fluctuating load. In such cases the
brushes should be adjusted to a position at which the least sparking
occurs with the average load.
Ques. What may be said with respect to reversal of polarity of dynamos?
Ans. When compound or series wound dynamos are running in parallel, their
polarity is occasionally reversed while stopping by the current from the
machines at work.
Loose Connections, Terminals, etc.--When any of the connecting cables,
terminal screws, etc., securing the different circuits are loose, sparking
at the brushes, as a rule, results, for the reason that the vibration
of the machine tends to continually alter the resistance of the various
circuits to which they are connected.
When the connections are excessively loose, sparking also results at their
points of contact, and by this indication the faulty connections may be
readily detected. When this sparking at the contacts is absent, the whole
of the connections should be carefully examined and tested.
Breaks in Armature Circuit.--If there be a broken circuit in the armature,
as sometimes happens through a fracture of the armature connections, etc.,
there will be serious flashing or sparking at the brushes, which cannot be
suppressed by adjusting the rocker. As a rule it results in the production
of "flats" upon one or more bars of the commutator.
[Illustration: Fig. 725.--Sandpaper holder for commutator. The sandpaper
is made fast on top by a clamp and screw. The two face blocks are
pivoted and adjust themselves to the commutator, and will fit any size of
commutator. If it have four brushes, the lower block will go in between
the brush-holders.]
Ques. How may such sparking be reduced without stopping the machine?
Ans. By placing one of the brushes of each set a little in advance of the
others, so as to bridge the gap.
Short Circuits in Armature Circuit.--This fault is indicated by sparking
at the commutator, and in bad cases by an excessive heating of the
armature, dimming of the light and slipping of the belt, and in the case
of a drum armature, by a sudden cessation of the current.
[Illustration: Fig. 726.--Sandpaper block. It is made to fit the surface
of the commutator. At S is a saw cut into which the ends are pushed after
being wrapped around the block. The latter should be cut down on the
dotted lines to form a handle.]
Short Circuits or Breaks in Field Magnet Circuit.--Either of these faults
is liable to give rise to sparking at the commutator. If one of the
coils be short circuited, the fact will be indicated by the faulty coil
remaining cool while the perfect coil is overheated. The fault may arise
through some of the connections to the coils making contact with the
frame of the machine or with each other. To ascertain this, examine all
the connections, and test with a battery and galvanometer. A total break
in one or more of the field coils may readily be detected by means of the
battery and galvanometer.
A partial break is not, however, so readily discovered, for the
reason that the coil wires may be in sufficiently close contact to
give a deflection of the galvanometer needle. The only methods of
detecting this fault is by measuring the resistance of the coils with
an ohmmeter or Wheatstone bridge, or by placing an ammeter in circuit
with each coil in turn, and comparing the amount of current flowing in
each. If the partial break be not accessible, the only way to remedy
the fault is to rewind the coil, and the same applies to a break in
the interior of the coil.
Short Circuits in Commutator.--These are of frequent occurrence, and
result in heating the armature and sparking at the brushes. They are
caused either by metallic dust or particles lodging in the insulation
between the segments, or by the deterioration of the commutator
insulation.
To remedy, the insulation between the segments should be carefully
examined, and any metallic dust, filings, or burrs cleaned or scraped
out. When the commutator is insulated with asbestos or pasteboard (as
is oftentimes the case in dynamos of European make), short circuits
very frequently occur through the insulation absorbing moisture or
oil, which is subsequently carbonized by the sparking at the brushes.
In faults of this description the only remedy is to expel all moisture
from the commutator insulation by means of heat, and scrape out all
metallic dust which may be embedded in the surface of the insulation.
If this do not effect a cure, it will be necessary to dig out the
insulation, as far as possible, with a sharp tool, and drive in new
insulation. Oil should not be used on commutators insulated with these
materials, but only asbestos dust or French chalk.
CHAPTER XXXIV
HEATING
The excessive heating of the parts of dynamos and motors is probably
the most frequent and annoying fault which arises in operation. When the
machine heats, it is a common mistake to suppose that any part found to
be hot is the seat of the trouble. Hot bearings may cause the armature or
commutator to heat, or vice versa.
All parts of the machine should be tested to ascertain which is the
hottest, since heat generated in one part is rapidly diffused. This is
best done by starting with the machine cold; any serious trouble from
heating is usually perceptible after a run of a few minutes at full speed
with the field magnets excited.
Heating may be due to various electrical or mechanical causes, and it may
occur in the different parts of the machine, as in:
1. The connections;
2. The brushes and commutator;
3. The armature;
4. The field magnet;
5. The bearing.
Ques. How is heating detected?
Ans. By applying the hand to the different parts of the machine if
low tension, or a thermometer if high tension, and also by a smell of
overheated insulation, paint, or varnish.
Ques. What should be done if the odor of overheated insulation, paint or
varnish be noticeable?
Ans. It is advisable to stop the machine at once, otherwise the insulation
is liable to be destroyed.
Ques. What is the allowable rise of temperature in a well designed machine?
Ans. It should not exceed 80° Fahr., above the surrounding air, and in
the case of the bearings, this temperature ought not to be reached under
normal conditions of working.
If this limit be exceeded after a run of six hours or less, it
indicates a machine either badly designed and probably with the
material cut down to the lowest possible limit with a view to
cheapness, or some fault or other which should be searched for and
remedied as early as possible, otherwise the machine will probably be
destroyed.
Ques. How should the rise of temperature be measured?
Ans. It is not sufficient to feel the machine with the hand, but special
thermometers must be placed on the armature winding, immediately on
stopping the machine, covering them with cotton or wool to prevent
cooling. Readings must be taken at short intervals, and continued till no
further rise of temperature is indicated.
Heating of Connections.--A rise of temperature of the connections may be
due to either excessive current, or bad contacts, or both. The terminals
and connections will be excessively heated if a larger current pass
through them than they are designed to carry. This nearly always proceeds
from an overload of the dynamo, and if this be rectified, the heating will
disappear.
If the contacts of the different connections of the dynamo be not
kept thoroughly clean and free from all grit, oil, etc., and the
connections themselves be not tightly screwed up, heating will result,
and the connections may even become unsoldered.
Heating of Brushes, Commutator and Armature.--When heating occurs in
these parts, it may be due to any of the following causes: 1, excessive
current; 2, hot bearings; 3, short circuits in armature or commutator; 4,
moisture in armature coils; 5, breaks in armature coils; 6, eddy currents
in armature core or conductor.
[Illustration: Fig. 727.--Ventilated commutator; sectional view showing
air ducts. Air is frequently circulated through a commutator in order to
maintain it at a sufficiently low temperature, suitable openings being
provided for this purpose as shown.]
Ques. What may be said with respect to excessive current?
Ans. When a dynamo is overloaded, the temperature of the armature will
rise to a dangerous extent, depending upon the degree to which the safe
capacity of the machine is exceeded, and heavy sparking of the brushes
will also result. If the overload be not removed, the insulation of the
armature may be destroyed.
Ques. State some causes of hot bearings.
Ans. Lack of oil; presence of grit or other foreign matter in the
bearings; belt too tight; armature not centred with respect to pole
pieces; bearings too tight; bearings not in line; shaft rough or cut.
[Illustration: Fig. 728.--Self-oiling and self-aligning bearing. The
self-oiling feature consists of rings which revolve with the shaft,
and feed the latter with oil continually, which they bring up from the
reservoir below. The dirt settles to the bottom, and the upper portion
of the oil remains sufficiently clean for a long time, after which it is
drawn off, and a fresh supply poured in through holes provided in the top.
These latter are often located directly over the slots in which the rings
are placed, so that the bearings can be lubricated immediately by means
of an oil cup if the rings fail to act or the reservoir become exhausted.
The bearing is made self-aligning by providing the bearing proper with
an enlarged central portion of spherical shape, held in a spherical seat
formed in the pedestal by turning, milling, or by casting Babbitt or other
fusible metal around it, thus allowing the bearing to adjust itself to
the exact direction of the shaft. The upper half of the box can be taken
off to facilitate renewal, etc., and to permit the armature to be removed.]
Ques. What is the effect of hot bearings?
Ans. Besides giving trouble themselves, the heat may be conducted along
the armature shaft and core, thus giving rise to excessive heating of the
armature.
POINTS RELATING TO HOT BEARINGS
1. Use good oil;
2. See that oil cups or reservoirs are full and all oil passages clear;
3. In self-oiling and splash systems where the oil is used over again,
it should be kept in clean condition by frequent straining;
4. Keep bearings clean and properly adjusted;
5. Maintain bearings in good alignment;
6. Avoid tight belts;
7. Examine the air gap or clearance between armature and pole faces and
see that they are uniform.
Ques. What troubles are encountered with short circuits in the armature
or commutator?
Ans. This results in sparking at the brushes, and in the heating of one
or more of the armature coils, and even in the burning up of the latter
if a bad case.
When the armature is overheated, and the defect does not proceed
from an overload or the causes mentioned below, the dynamo should be
immediately stopped and tested for this fault.
Ques. What will happen with an overheated commutator?
Ans. It will decompose carbon brushes and cover the commutator with a
black film, which offers resistance and increases the heat.
Ques. What should be done if carbon brushes become hotter than the other
parts?
Ans. Use higher conductivity carbon. Reduce length of brush by adjusting
holder to grip brush nearer the commutator. Reinforce brushes with
copper gauze, sheet copper or wires, or use some form of combined metal
and carbon brush. Increase size or number of brush if necessary, so the
current does not exceed 30 amperes per square inch of contact.
Brushes heat sometimes due to too much friction. They should not press
against the commutator more than is necessary for good contact.
Ques. Give some causes for heating of armature.
Ans. Eddy currents; moisture; short circuits; unequal strength of magnetic
poles; operation above rated voltage, and below normal speed.
Ques. What trouble is encountered with eddy currents?
Ans. Considerable heating of the whole of the armature results, which may
even extend to the bearings.
[Illustration: Fig. 729.--Eck Manchester type motor. It is a very small
size unit and is designed for special purposes where very little room is
available. The motor occupies a space of 2-1/2" × 4-3/8" between bearings
and develops 1/16 horse power at 2,000 R. P. M. The frame of this motor is
made of high permeability steel so as to reduce the weight to a minimum.
The armature is of the hand wound bipolar type built up of thin punchings.
The armature, after being wound, is baked at high temperature for a
prolonged period and then dipped while hot in insulating varnish. Pulley
is one inch in diameter and takes a 1/4 inch round belt. Weight of motor
5-1/2 pounds.]
Ques. How can this be overcome?
Ans. There is no remedy for eddy currents other than the purchase of a
new armature, or reconstruction.
The fault may be detected by exciting the field magnets and running
the machine on open circuit, with the brushes raised off the
commutator for some time, when the armature will be found to be
excessively heated.
Ques. How does moisture in the armature coils affect the armature?
Ans. The effect of this fault being to practically short circuit the
armature, a heating of the latter results. In bad cases, steam or vapor
is given off.
Ques. What is the effect of short circuits in the armature?
Ans. It produces overheating.
Ques. What trouble is likely to occur when the armature is not centered
in the armature chamber?
Ans. A heating of the bearings is liable to be occasioned through the
attractive forces developed by the center of the armature core not being
parallel with the centre of the armature chamber or bore, or through the
core being nearer one pole piece than the other.
This may result from unequal wearing of the bearings, and therefore
the bearings should either be relined or the bolt holes of the
bearings readjusted, or the bearings packed up until the armature is
correctly centered.
Ques. What happens in case of breaks in the armature coils?
Ans. This fault results in local heating of the armature, for the reason
that resistance is interposed in the path of the current at the fracture.
It always results in sparking at the brushes, and the heating being
confined to the neighborhood of the break.
Ques. What are the effects of operation above the rated voltage and below
normal speed?
Ans. Voltage above normal is a possible cause of heating, and operation
below normal speed calls for an increase of field strength and reduces
the effective ventilation, thus tending to cause heating.
[Illustration: Fig. 730.--Forced system of lubrication as applied to
engine of the generating set shown in fig. 443. In engines employing
the forced system of lubrication the crank pit, which is formed by the
columns, is accessible through doors in the front and back of the engine.
The base of the engine forms an oil tank to which is attached a small
plunger pump driven by an eccentric on the shaft. The lubricant is carried
under pressure to the various parts of the engine by the mechanism shown
in the accompanying diagram. The oil is forced by a pump to a groove in
the main bearing, and a drilled hole in the shaft connects this groove
with the crank pin. From the crank pin box the oil is further forced to
the wrist pin through the pipe running along the side of the connecting
rod. The passage in the crosshead allows the oil to be forced from the
wrist pin to the guides. As the oil is forced from one bearing to another,
it is quite important that the bearing caps be set tight, otherwise the
oil will escape before reaching the last bearing. After passing through
the bearings, the oil is collected in the base, strained and used again.
The oil should be free from foreign substances, and to guard against the
introduction of any foreign matter, a strainer, which may be taken out for
examination or cleaning, is attached to the suction valve of the pump.
An oil pressure of from 10 to 20 lbs. should be maintained, and may be
regulated by adjusting the set screw on the relief valve of the oiling
system. The pressure gauge need not remain in the circuit continuously.
Only mineral oils should be used for lubrication. A heavy oil gives better
results and prevents knocking more effectively than thin oil. An oil which
has been found to give good results, consists of two-thirds red engine oil
and one-third heavy cylinder oil. As the oil passes through the bearings
repeatedly, it gradually loses its lubricating properties, becoming thick
and gritty, and should be occasionally run through a filter and mixed with
new oil. The frequency of this change depends on the oil, as well as the
number of hours the engine is in operation, and can easily be determined
by observation. The oil in the reservoir should stand about 2 inches over
the suction and discharge valves, and no water should be allowed to mix
with it. Should any water accumulate in the base, it should be drawn off
by the cock provided for the purpose before starting the engine.]
Ques. How may the field magnets become heated?
Ans. By excessive field current; eddy current in pole pieces; moisture;
short circuits.
Ques. What may be said with respect to excessive field current?
Ans. When heating results from this cause, all the exciting coils will be
heated equally. It may be due to excessive voltage, in the case of shunt
dynamos; or to an overload in the case of compound and series dynamos. In
either case it may be remedied by reducing the voltage or overload. If due
to the coils being incorrectly coupled up, that is, coupled up in parallel
instead of in series, it will be necessary to rectify the connections or
insert a resistance in series.
Ques. State the causes of eddy currents in the pole pieces?
Ans. This fault may be due to defective design or construction of the
armature. Slotted armatures are particularly liable to cause this fault,
if the teeth and air gap be not properly proportioned. The defect may also
be occasioned by variation in the strength of the exciting current.
If due to this latter cause, it will be accompanied by sparking at the
brushes. If a shunt dynamo, insert an ammeter into the shunt circuit,
and note if the deflection be steady. If this be not the case,
the variation in the current most probably proceeds from imperfect
contacts thrown into vibration.
Ques. How is the insulation affected by moisture?
Ans. Moisture tends to decrease the insulation resistance, thus in effect
producing a short circuit with its attendant heating.
Ques. How is moisture in the field coils detected?
Ans. It is easily detected by applying the hand to the coils, when they
will be found to be damp, and in addition steam or vapor will be given
off where the machine is working.
The fault may be remedied by drying and varnishing the coils.
Ques. What is the indication of short circuits in the field coils?
Ans. This fault is characterized by an unequal heating of the field coils.
If the coils be connected in series, the faulty coil will be heated to a
less extent than the perfect coils; if connected in parallel, the faulty
coil will be heated to a greater extent than the perfect coils. The former
can thus be easily located.
CHAPTER XXXV
OPERATION OF MOTORS
In operating motors of any considerable size, whether connected to the
public supply mains of a central generating station for combined lighting
and power service, or to power service mains only, there are certain
precautions to be observed in starting, stopping, and regulating the
motor, in order that the efficiency of the supply, and indirectly the
working of other motors and lamps connected to the mains in the immediate
neighborhood, may not be affected by abnormal variations of pressure.
These precautions should be observed also to prevent any danger of
the motor itself being subjected to detrimental mechanical shocks and
excessive temperatures in the working parts.
Before Starting a Motor.--The general instructions relating to inspection
and adjustment, lubrication, etc., which have already been given, should
be carefully followed preparatory to starting[E].
[E] NOTE.--In starting a motor, first see that the bearings contain
sufficient oil and that the brushes bear evenly on the commutator. If a
circuit breaker be used, close it; then close the main switch. Rotate
slowly the handle of the starting rheostat as far as it will go. Care
should be taken, in starting the motor, that the handle of the rheostat be
not rotated too fast. To stop a motor, open the circuit breaker or switch,
which will cut in the resistance of the starting box. Never attempt to
stop a motor by forcibly pulling open the starting box, _Disregard of
these instructions may cause burning out of the field coils._
Starting a Motor.--In starting a motor, resistance must be put in series
with the armature because, since there is no reverse electromotive force
to counteract the applied voltage when the motor is at rest, the switching
of the latter direct to the motor would result in an abnormal rush of
current. This, in addition to being uneconomical and productive of a drop
of voltage in the mains, would injure all except the smallest motors.
Hence motors above two horse power usually require a rheostat.
Ques. Describe a rheostat or "starting box."
Ans. It consists essentially of a suitable resistance to be inserted at
starting to reduce the initial rush of current, and which can be cut out
in sections by successive movements of a lever as the speed increases.
[Illustration: Fig. 731.--Press for forcing on and removing a commutator.
Small commutators are pressed on to the shaft by a hand press. All of
the larger commutators are pressed on by means of a power press. In the
above figure is shown a hand press. The plate _B_ is used in removing
old commutators. It is placed back of the commutator as at _x y_ with
the slot _C_ over the shaft. Bolts _a b_ are passed through the holes in
the plate and secured by nuts. The commutator can then be forced off the
shaft. In pressing on a commutator, a sleeve is placed over the shaft at
_O_, and against the commutator. The rear end of the shaft is secured so
it will withstand the pressure, and the commutator is forced on. The power
presses are built on the principle of a hydraulic press. In pressing on a
commutator a piece of babbitt metal or soft brass should be used against
the end of the shaft. The shaft should be painted with white lead before
having the commutator pressed on, in order to lubricate the shaft so that
the commutator will press on easily. The wiper rings are pressed on after
the commutator and then the armature is ready to be connected.]
Ques. Describe what occurs in starting a motor.
Ans. When the lever of the starting box is moved to the first contact some
of the resistance is cut out of the circuit and current flows through
the motor. This produces a torque and starts the armature rotating. The
movement of the armature induces a reverse voltage, which, as the speed
increases, gradually reduces the applied current. With this reduction of
current, the torque is reduced and the speed not accelerated as quickly as
at first. When the applied current has been reduced to a certain value by
the increasing reverse current, the handle of the starting box is moved
to the next contact, and so on till all the resistance in the starting
box has been cut out, the motor then attaining its normal speed.
[Illustration: Figs. 732 to 735.--Various starting resistances. The type
of resistance used in motor starting rheostats of small size consists
usually of tinned iron wire wound on asbestos tubes, as shown in fig. 732,
the tubes being firmly supported by porcelain nipples, the ends of which
fit into holes in the top and bottom of the enclosing case. In starters of
larger size, cast metal grids, as shown in fig. 733, are used. In addition
to these types of resistance, some forms of starter are equipped with
what is known as "unit" type resistance. In this form, the resistance is
built up of a number of separate sections, or units, which are connected
to form the complete starting or regulating resistance as the case may be.
A single unit consists of a moulded core of vitreous material upon which
is wound the resistance wire, as shown in fig. 734. The surface of the
unit is then coated with a special cement and baked. By this method the
resistance material is protected from mechanical injury and is also made
proof against moisture and other conditions which sometimes affect the
ordinary type of resistance. In addition to units coated with cement only,
there are still other types of units, as in fig. 735, which are provided
with a sheet metal covering around the cement, as a further precaution
against injury. Each of the various types of resistance described
possesses certain characteristics not shared by the others, the use of
any particular type being largely governed by conditions of service.]
Ques. What is the difference between a starting box and a speed regulator?
Ans. Motor starting rheostats or "starting boxes," are designed to start
a motor and bring it gradually from rest to full speed. They are _not_
intended to regulate the speed and must not be used for such purpose.
_Failure to observe this caution will result in burning out the
resistance which, in a motor starter, is sufficient to carry the
current for a limited time only_, whereas in the case of speed
regulators sufficient resistance is provided to carry the full load
current continuously.
[Illustration: Fig. 736.--View of Cutler-Hammer starter with slate front
removed showing open wire coil resistance. The type of resistance here
used consists of tinned iron wire wound on asbestos tubes. The bottom of
the casing is perforated to secure ventilation.]
Ques. For what kinds of service are speed regulators used?
Ans. In cases when the speed must be varied, as in traction motors, organ
blowers, machine tool drive, etc.
Ques. How long does it take to start a motor?
Ans. Usually from five to ten seconds.
Ques. How is the starting lever operated?
Ans. It is moved progressively from contact to contact, pausing long
enough on each contact for the motor to accelerate its speed before
passing to the next.
Ques. What are the conditions at starting in a series motor?
Ans. There is a rush of current, the magnitude of which depends on the
amount of resistance cut out at each movement of the starting lever.
[Illustration: Figs. 737 and 738.--Sliding contact starters. Fig. 737,
starter with button contacts; fig. 738, starter with renewable contacts.
Motor starters in which the successive steps of resistance are cut out by
a pivoted lever carrying a contact shoe which slides over button contacts
or over contact segments, are known as sliding contact starters. Button
contacts are usually furnished with motor starting rheostats of small size
while contact segments are used on those of greater capacity. The contact
segment being held in position by two screws, is readily renewable when
worn by long service or damaged by arcing. The fixed button contact is
not so easily renewed but being used only on small size starters is never
likely to be subjected to severe service. Some starters, however, have
renewable button contacts.]
Ques. How are small series motors started on battery circuits?
Ans. By simply closing a switch to complete the circuit, the resistance
of the battery being sufficient to prevent a great rush of current while
starting.
Ques. How is a shunt motor started?
Ans. In starting a shunt motor, no trouble is likely to occur in
connecting the field coils to the circuit. Since the resistance of the
armature is very low, it is necessary on constant voltage circuits to use
a starting rheostat in series with the armature.
The necessary connections are shown in fig. 756. The switch is first
closed thus sending current through the field coils, before any
passes through the armature. The rheostat lever P is then moved to the
first contact to allow a moderate amount of current to pass through
the armature. The resistance of the rheostat is gradually cut out by
further movement of the lever P, thus bringing the motor up to speed.
[Illustration: Figs. 739 and 740.--Multiple switch starters. Fig. 739,
starter with no voltage release; fig. 740, starter with no voltage release
and circuit breaker. The multiple switch type of starter is designed
to overcome the arcing on sliding contacts which, in the case of large
motors would be very severe. The cutting out of each step of resistance is
accomplished in the multiple switch starter by a separate carbon contact
switch which breaks the circuit with a quick snappy action.]
Ques. How does the reverse voltage affect the starting of a motor?
Ans. When a motor is standing still, there is no reverse voltage, and
the current taken at first is governed principally by the resistance of
the circuit. If the motor be series wound, there is a momentary reverse
voltage, due to self-induction while the field is building up. If the
motor be shunt wound, self-induction delays the current through the
field coils, but that through the armature is not impeded by such cause.
When the armature begins to revolve, reverse voltage is developed which
increases with the speed. The resistance of the starting box may be
gradually cut out as the armature comes to speed. Thus the reverse voltage
gradually replaces ohmic drop in limiting the current as the motor comes
to speed.
[Illustration: Fig. 741.--Starting rheostat with no voltage and overload
release. The no voltage release permits the starting lever to fly to
the "off position" should the voltage fail momentarily, thus protecting
the motor against damage should the voltage suddenly return to the
line. The movement of the lever is due to a spring. The overload device
causes the lever to back to the off position should the current exceed a
predetermined maximum for which the release is adjusted.
Fig. 742.--Compound starter. Rheostats designed for the double duty of
starting a motor and regulating its speed are commonly known as compound
starters, the resistance provided being a combination of armature
resistance for starting duty and shunt field resistance for speed
regulation.]
Failure to Start.--This fault, which is liable to occur in a motor of any
description, is similar to failure to excite in a dynamo, and is liable to
be produced by any of the causes mentioned in connection with the latter
fault, excluding insufficient speed, and insufficient residual magnetism.
When a motor fails to start, it should first be ascertained if a supply
of electrical energy be available in the mains. This may readily be
discovered by means of a voltmeter, or if low tension service, by means of
the fingers bridging across the main terminals. If the supply of energy
be present, the contact arm of the starter should be moved into such
position that all resistance is inserted into circuit with the motor. This
is important, as the motor may start suddenly while trying to ascertain
the cause of the stoppage.
[Illustration: Fig. 743.--Starting panel. In installing any kind of motor
starting rheostat, it is necessary to provide main line knife switch and
fuses in addition to the starting box. The appearance of the installation
can be much improved by mounting all of these upon one panel.]
Having closed the switch, if the motor fail to start, it will be advisable
to remove the load if possible, as the failure may arise from an overload
of the machine. This being effected and the motor not starting, the
terminals of the latter should be tested by the means already described
for voltage. If no voltage be generated, a broken circuit or a defective
contact may be looked for in the main fuse, switch, or starting box. The
resistance coils of the latter, through the heat developed, frequently
break in positions out of sight. If a defective contact of this nature
cannot readily be seen, the contact arm should be moved slowly over the
contacts, as it is possible the broken coil may be cut out of circuit by
this means.
[Illustration: Figs. 744 to 746.--Cutler-Hammer motor starting rheostats
with no voltage and overload release. Fig. 744, starter with fixed button
contact, fig. 745, with renewable button contact, and fig. 746, with
contact segments. In construction the resistance is enclosed in a pressed
steel box on which is mounted a marbleized slate panel carrying the
starting lever, contacts and protective devices. By means of a calibrated
scale, the overload release (shown in the lower left hand corner, figs.
744 and 745, and in the lower right hand corner fig. 746) can be set
to break the circuit on any overload not exceeding 50 per cent. of the
rated capacity of the motor. This calibrated scale can also be used for
determining, with a fair degree of accuracy, the amount of current being
consumed by the motor.]
If a difference of pressure exist between the motor terminals, the
field magnets will, if shunt or compound wound and in good order,
be excited, which may be ascertained by means of a bar of iron. If
no magnetism be present, it will of course, indicate a broken or
bad connection, either between the terminals of the field coils, or
one or more of the coils themselves. If the bar pull strongly, the
position of the brushes upon the commutator in regard to the neutral
points should be ascertained, and the rocker adjusted, if necessary,
to bring them into their correct positions. If this fail to start the
motor, the connecting leads from the motor terminals to the brushes
and the brushes themselves should be carefully examined for broken
or bad connections, and defective contact of the brushes with the
commutator. In the latter case, it may arise from a dirty state of
the commutator, or from the brushes not being fed properly. If due
to these causes, pressing the brushes down upon the commutator with
the fingers will probably start the motor. If the failure to start
arise from none of these causes, it is probably due to the field coils
acting in opposition, or to a short circuited armature. This latter
remark applies more especially to motors provided with drum armatures.
[Illustration: Fig. 747.--Allen-Bradley compression type resistance units.
The contact resistance between the discs composing the resistance column
is subject to variations of pressure thereby producing proportionate
resistance changes in the column as a whole. In the complete resistance
unit, the resistances column is encased in a drawn steel tube, which
is lined with a highly refractory cement, for purpose of insulation,
_affording the column both mechanical and electrical protection_ and
excluding the air which effectually prevents any combustion should the
column become red hot due to overload. The ends of the tube are closed by
means of caps through which pass electrodes for making connections between
the discs and exterior conductors. The steel tube, when necessary, is
provided with ribs or fins for the dissipation of acquired heat.]
[Illustration: Fig. 748.--Allen-Bradley type Z automatic motor starter.
The operation of this machine is as follows: When the main switch is
closed, the motor circuit is made through the fuses, resistance unit,
current relay, and the motor armature. At the same time, the solenoid
circuit is closed (this is connected directly across the line, and takes
a current which is a small fraction of an ampere), and the plunger of
the solenoid is drawn up, which produces a pressure on the resistance
unit, and increases the current in the motor circuit to the predetermined
value at which the current relay is set. When this value is reached the
current relay operates and opens the solenoid circuit, which reduces the
magnetic pull and allows the solenoid plunger to drop back slightly. This
action increases the resistance in the motor circuit, which decreases the
current sufficiently to allow the relay to close again. Similar cycles
of operation are repeated as the motor accelerates, and each time the
plunger is drawn a little farther into the solenoid, until the short
circuiting contacts on the top are pushed together, which short circuits
the current relay and resistance unit, making them inoperative, and
completing the operation of starting the motor. It will be noted that in
starting a motor with this device the current is always held down to a
certain predetermined value, and it is impossible to overload the motor
by too rapid starting. The current relay is calibrated in amperes, and
may be set to suit existing conditions. The action of the starter being
controlled by a current relay and not by an oil or air dash pot, the motor
will start rapidly when under a light load, and slowly when more heavily
loaded. The fuses or circuit breakers may be set at a value that will
furnish protection to the motor under running conditions.]
Precautions with Shunt Motors.--With motors of this type, because of the
large amount of self-induction in the shunt windings, it is important to
note: 1, that in switching on the field magnet, the current may take an
appreciable time to grow to its normal value, and 2, that in switching
off, especially with quick break switches, high voltages are induced in
the windings, which may break down the insulation.
[Illustration: Fig. 749.--Monitor starter giving automatic start with
knife switch control; designed for use with printing presses. It consists
of a set of solenoids connected in series and so interoperating as to cut
resistance out of the armature circuit of the motor as the apparatus it
is driving comes up to speed. This type is for small motors or where no
need arises for speed regulation; there is, therefore, no adjustment of
speed possible aside from an actual change in motor conditions. At full
speed the motor is directly across the main supply line.
Fig. 750.--Monitor automatic starter, equipped with relay for push button
control.]
Ques. What provision is made so that the magnetizing current will have
time to reach its normal value?
Ans. The field connections are generally separated from the actual
starter, and taken to the main switch, so that wherever the main switch
is closed, the current flows through the field coils, before the starting
lever is moved.
Ques. How are the connections arranged to avoid excessive voltage in the
windings due to self-induction?
Ans. Generally the armature and field magnet circuits are placed in a
closed circuit that is never opened.
In other cases, in order that the rise of voltage may not injure the
insulation when the shunt is opened, a special form of main switch
is sometimes used which, before breaking from the supply, puts a
non-inductive resistance across the shunt of the motor. This is known
as a _flashing resistance_.
[Illustration: Figs. 751 to 753.--Monitor control switches. Fig. 751, push
button "start" and "stop" switch; fig. 752, safety lever control switch
with "slow" and "fast" buttons for rotary printing presses. This device
will upon pressure of the "start" button, set the machine in motion and
bring it up to the predetermined speed, either as previously set by the
starter limits or by the setting of the rheostat arm. The stop button
projects some distance beyond any other portion of the device, in order
that in case of emergency the operator may stop the machine merely by
hitting the face of the switch with his open hand. The lever control
switch, fig. 753, is similar in its action to the push button switch but
combines two other features: locking point, and visual indication of the
station from whence the press has been stopped. With the lever at the
downward position, the press is locked and cannot be started from any
other station. In order to make the press ready to start the lever must
be raised to the central position. Thus a man may safely enter the press
without delay by setting his station to the locked position, knowing
that it cannot be started except by some one coming to that station and
realizing that the press has been purposely locked. Also, by looking along
the press, it is possible to tell from which station it has been locked,
and proper action can be immediately taken. The safety control station
is usually combined for use on large rotary presses with the "slow" and
"fast" push buttons as shown in fig. 752. A pressure upon the fast or
slow buttons will cause the press speed to be correspondingly accelerated
or retarded, and this action will continue so long as the button is
pressed. The press continues to run at the speed attained at the instant
of releasing the button. Any speed may, therefore, be selected or changed
to suit momentary requirements. This gives complete control excepting
reversal which is not required of such a press.]
[Illustration: Fig. 754.--Wiring diagram of the standard form of
Monitor controller. A set of solenoids are connected in series and so
interoperating as to cut resistance out of the armature circuit of the
motor as the apparatus it is driving comes up to speed. The controller
is designed to be used on all classes of work. In its simplest form,
a single copper and graphite contact, is controlled by two magnets,
so proportioned as to cut out the entire starting resistance when the
armature current falls to a predetermined value. In the larger sizes,
the number of steps controlling the resistance is increased and arranged
to produce the correct acceleration. In every case the regulation of the
starting resistance is effected entirely by the current passing to the
motor without the use of dash pot, mechanical governor or delicate cut
outs. The time element is thus directly proportioned to the load and the
motor brought up to speed in the shortest time consistent with the load,
but always with safe limitation of the armature current. The distinction
between the current controlled starter and the starter with dash pot
governor should be noted. The starter here shown limits the starting
current to a fixed value throughout the starting operation, which is an
ideal condition and prevents blowing fuses in starting.]
Ques. How can shunt motors be controlled from a distant point?
Ans. The starter and switch are placed at the desired point and the two
main wires and the field wires run from that point to the motor.
This requires additional wire which increases the cost and line loss.
Regulation of Motor Speed.--Motors are generally run on constant voltage
circuits. Under these conditions, the speed of series motors varies with
the load and at light loads becomes excessive. Shunt motors run at nearly
constant speeds.
For many purposes, particularly for traction, and for driving tools, it
is desirable to have speed regulation, so that motors running on constant
voltage circuits may be made to run at different speeds.
The following two methods are generally used for regulating the speed of
motors operated on constant voltage circuits:
1. By inserting resistance in the armature circuit of a shunt wound motor;
2. By varying the field strength of series motors by switching sections
of the field coils in or out of circuit.
Ques. Describe the first method.
Ans. This method is illustrated in fig. 756. When the main switch is
closed, the field becomes excited, then by moving the lever P of the
starting rheostat the various contacts (1, 2, 3, 4, 5), more or less of
the rheostat resistance is cut out of the armature circuit, thus varying
the speed correspondingly.
This is the same as the method of starting a motor, that is, _by
variation of resistance in armature circuit_, but it should be
noted that when this method is used for speed regulation, _a speed
regulating rheostat should be used instead of the ordinary starting
box_, because the latter, not being designed for the purpose, _will
overheat and probably burn out_.
[Illustration: Fig. 755.--Monitor printing press controller. It provides
variable speed and other control features required in the operation
of large rotary presses, such as those used for printing newspapers.
From any one of various stations similar to the one illustrated in fig.
753, located at all desirable places about the press, the latter may be
started, stopped, accelerated, slowed down or locked. It differs from
other types of printing press controller in that the solenoid has an
overall maximum pull of less than one inch and does not actuate the main
line current directly but through pilot circuits, which in turn, operate
flapper switches; there are no sliding contacts. At the control stations,
the operator can distinguish the accelerating button from the retarding
button by the sense of touch and obviously he can in the same manner
ascertain the position of the lever. The position of the lever whether
at start, stop or safety, can be readily observed at a distance. When
the lever of either control station is placed at stop, the current is
disconnected from the motor and a powerful dynamic brake brings the press
to rest without delay and without shock or harmful strain. The start will
always be made with all resistance in the armature circuit, and with full
field, and should the current supply fail, the controller will release and
open the circuit to the motor. This controller will give a speed range as
low as 10% of normal speed by armature resistance and, by field control,
any increase within the speed of the motor.]
Ques. Describe the second method.
Ans. This method of regulating the speed of a series motor is shown in
fig. 757. The current through the armature will flow through all the field
windings when the position of the switch lever S, is on contact 4, and the
strength of the field will be the maximum. By moving the arm to contact
3, 2, etc., sections of the field winding are cut out, thus reducing the
strength of field and varying the speed.
[Illustration: Fig. 756.--Speed regulation of shunt motor by variable
resistance in the armature circuit.]
Ques. How does the speed vary with respect to variation of field strength?
Ans. Decreasing the field strength of a motor increases its speed, while
increasing the field strength decreases the speed.
Under the conditions of maximum field strength, as with switch S on
point 1, the torque will be greatest for any given current strength
and the reverse voltage also greatest at any given speed. The current
through the armature of the motor, to perform any given work, will
thus be a minimum, as well as the speed at which the motor has to run,
in order to develop sufficient reverse voltage to permit this current
to flow. Regulation of speed by varying the field strength is limited
in range of action, since the field saturation point is soon reached,
moreover, with too low a field strength, armature reaction produces
excessive field distortion, sparking, etc.
[Illustration: Fig. 757.--Speed regulation of series motor by cutting out
sections of the field winding. In this method the field winding is tapped
at several points, dividing the coil into sections and the leads from
these points are connected a multi-point switch of the type that would
be used on a rheostat. By moving the lever S, to the left or right, the
current will flow through one or more sections of the field winding, thus
decreasing or increasing the ampere turns and thereby providing means of
regulation.]
[Illustration: Fig. 758.--Speed regulation of a series motor by the method
of short circuiting sections of the field winding. It will be seen that
there are seven different positions for the contact springs on the barrel
contacts. A. represents the armature and brushes, little A, B, and C,
the divided field magnet coils, L the line connection, and G the earth
connection. The diagram shows the connections for trolley car operation.]
Ques. How is the speed of shunt and compound motors varied with respect
to the normal speed in the two methods?
Ans. The first method (variable resistance in armature circuit) reduces
the speed _below_ the normal or rated speed of the machine, while the
second method increases the speed _above_ the normal.
In the first method the amount of speed reduction depends partly upon
the amount of resistance introduced into the armature circuit, and
partly upon the load.
In the second method the amount of speed increase depends entirely
upon the amount of resistance placed in the shunt winding circuit.
Eighty-five per cent. is about the maximum speed reduction obtainable by
armature resistance but so great a reduction is seldom satisfactory since
comparatively slight increases in the load will cause the motor to stall.
Shunt field regulation may be obtained up to any point for which the
motor is suited, the only limitation in this case being the maximum
speed at which the motor may be safely operated.
It should be remembered, however, that speed increase by shunt field
weakening increases the current in proportion to the increase in
speed, and care should be taken not to overload the armature.
NOTE.--A compound motor may be made to run at constant speed, if
the current in the series winding of the field be arranged to act in
opposition to that of the shunt winding. In such case, an increase
of load will weaken the fields and allow more current to flow through
the armature without decreasing the speed of the armature, as would be
necessary in a shunt motor. Such motors, however, are not very often
used, since an overload would weaken the fields too much and cause
trouble. If the current in the series field act in the same direction
as that in the shunt fields, the motor will slow up some when a heavy
load comes on, but will take care of the load without much trouble.
NOTE.--Motors have much the same faults as dynamos, but they make
themselves manifest in a different way. An open field circuit will
prevent the motor starting, and will cause the melting of fuses or
burning out of the armature. A short circuit in the fields, if it cut
out only a part of the winding, will cause the motor to run faster and
very likely spark badly. If the brushes be not set exactly opposite
each other, there will also be bad sparking. If they be not at the
neutral point, the motor will spark badly. Brushes should always be
set at the point of least sparking. If it become necessary to open the
field circuit, it should be done slowly, letting the arc gradually
die out. A quick break of a circuit in connection with any dynamo,
or motor is not advisable, as it is very likely to break down the
insulation of the machine. The ordinary starting box for motors is
wound with comparatively fine wire and will get very hot if left in
circuit long. The movement of the arm from the first to the last point
should not occupy more than thirty seconds and if the armature do not
begin to move at the first point, the arm should be thrown back and
the trouble located.
[Illustration: Fig. 759.--Cutler-Hammer multiple switch starter with no
voltage release; for use with large motors, or with motors of medium size
where the starting conditions are severe or when more than fifteen seconds
are required to accelerate the motor. In operation, the cutting out of
each step of resistance is accomplished by a separate lever and the levers
themselves are so interlocked as to prevent closing switches except in
proper order, beginning with the lever on the left. The last switch (the
one on right hand side) is held by an electro-magnet when closed, each
of the other switches being held in the closed position by a latching
device on the switch next to it. In front of each switch is placed a metal
stop, so arranged as to prevent any switch being operated until the one
next to it on the left has been closed. These metal stops constitute the
interlocking mechanism and prevent the starting of the motor in any way
except by closing the switches in regular rotation, thus insuring proper
resistance in the circuit and protecting the motor from excessive starting
currents. When the current is interrupted, the electro-magnet releases
the last switch, which, on opening, releases the latch on the switch next
to it, allowing that switch to open, and this in turn releases the next
latch and so on, the switches opening automatically one after another.
In starting the motor, each switch should be closed quickly and firmly,
pausing a second or two before closing the next switch to give the motor
time to accelerate.]
[Illustration: Fig. 760.--Cutler-Hammer speed regulator with no voltage
release, _regulation by armature resistance only_, reducing speed of motor
_below normal_. No resistance in the armature circuit. No provision is
made in regulators of this type for increasing the speed of the motor. The
maximum speed obtainable when these regulators are used is, therefore, the
normal speed at which the motor is designed to operate with no resistance
in circuit. With all resistance in circuit and the motor taking normal
current these regulators will reduce the speed of the motor 50 per cent.
If the motor be taking less than normal current the percentage of speed
reduction obtainable will be correspondingly less. The notched fan tail
extension on the lower end of the lever engages with a magnetically
operated pawl to hold the lever squarely on any contact so long as the no
voltage release magnet is energized.]
Ques. How is a wide range of speed regulation secured?
Ans. By a combination of the two methods.
Regulation by Armature Resistance.--Speed regulators for this method
of regulation, are designed to carry the normal current on any contact
without overheating and when all the resistance is in the circuit, they
will reduce the speed of the motor about 50 per cent. provided the motor
be taking the normal current. When operating without resistance in the
armature circuit, shunt wound and compound wound motors will regulate
to approximately constant speed regardless of load. This characteristic
of inherent regulation is lost, however, when armature resistance is
employed to reduce the speed of the motor, fluctuations in load resulting
in fluctuations in speed, which become more noticeable as the amount of
resistance inserted in the armature circuit is increased. Accordingly,
it becomes necessary to move the lever of the speed regulator forward
or backward to again obtain the speed at which the machine was operating
before the load changed.
[Illustration: Fig. 761.--Cutler-Hammer compound starter with no voltage
and overload release. This is a starting rheostat and field regulator
combined. In operation, two levers are employed, both being mounted on
the same hub post and one lying directly under the other. The upper lever
only is provided with a handle, but when moving from the off position to
the starting position (that is to say, from left to right) the lower, or
starting, lever is carried along by the upper, or speed regulating, lever
until it comes in contact with the no voltage release magnet where it is
held fast by the attraction of the magnet, leaving the upper lever free
to be moved backward over the field contacts, thus weakening the shunt
field of the motor little by little until the desired speed is attained.
During the operation of starting the motor, the field resistance is
short circuited by an auxiliary contact (the slotted metal strip shown
near center of rheostat) but as soon as the starting lever touches the
no voltage release magnet or, in other words, when the motor has been
accelerated to normal speed, this short circuit is removed, and the
field resistance becomes effective for speed regulation. The motor is
accelerated from rest to normal speed by moving both levers from left to
right, while increases in speed above normal are obtained by moving the
upper lever from right to left. Only the lower, or starting lever comes
into contact with the no voltage release magnet. This lever is provided
with a strong spiral spring which tends always to throw the lever back
to the off position. Hence should the voltage fail, the no voltage
release magnet releases the starting lever and this, in flying back to
the off position, opens the armature circuit of the motor and carries the
speed regulating lever with it to the off position. The upper, or speed
regulating lever, not being influenced by the spring, though mounted on
the same hub post as the starting lever, may be moved back and forth at
will or left indefinitely in the position which gives the speed desired.]
When the speed of a motor driving a constant torque machine is
reduced by inserting resistance in the armature circuit there is
no corresponding reduction in current consumed. The motor runs more
slowly simply because a part of the energy impelling it is shunted
into the resistance and there dissipated in the form of heat. Hence,
whether the motor be operating at full speed or half speed, the amount
of current consumed is the same; the only difference being that in the
one case all the energy taken from the line is expended in driving the
motor while in the other case only one half is utilized for power,
the other half being dissipated in the resistance. Speed regulation
by armature resistance only is therefore open to two objections:
1, the difficulty of maintaining constant speed under varying load
conditions, and 2, the necessity of wasting energy to secure speed
reduction. These objections are, in part, offset by the fact that
speed reduction by armature resistance may be applied to any motor of
standard design and requires nothing more than the simplest and least
expensive speed regulating rheostat.
In cases where the motor will be operated nearly always at full speed,
the difference in first cost of the installation may justify the
use of the armature resistance method of control. As a rule, speed
regulation by shunt field resistance is preferable.
[Illustration: Fig. 762.--Cutler-Hammer compound speed regulator with no
voltage and overload release; _regulation by combined armature and shunt
field resistance_, designed to both decrease and increase the speed of
a motor. Speed reduction is accomplished by inserting resistance in the
armature circuit, the maximum amount of speed reduction obtainable with
these controllers being 50 per cent. below normal. Speed increase is
obtained by inserting resistance in the shunt field circuit, the maximum
amount of speed increase obtainable with these controllers being 25 per
cent. above normal.]
Regulation by Shunt Field Resistance.--Since regulation by this method is
for speeds above normal, a starter must be used to bring the motor up to
its rated speed. Usually the starter is combined with the regulator, as
shown in fig. 761, the device being called a _compound starter_.
[Illustration: Figs. 763 to 765.--Holzer-Cabot shunt wound motor; diagrams
showing connections and positions of index point for forward and reverse
rotation.
LOCATION AND SETTING.--The motor should be placed in as cool, clean and
well ventilated a location as possible, away from acid or other fumes
which would attack the metal parts or insulation, and should be easily
accessible for cleaning and oiling. Do not put it in some corner where
care of motor will be neglected because of the trouble of getting at
it. The motor should be set so that the shaft is level and parallel with
the shaft it is to drive so that the belt will run in the middle of the
pulleys. Do not use a belt which is much too heavy or too light for the
work it has to do, as it will materially reduce the output of the motor.
The belt should be about one-half inch narrower than the pulley.
ROTATION.--In order to reverse the direction of rotation, interchange
leads A and B, and shift brush ring as shown in the diagram above.
SUSPENDED MOTORS.--Motors with ring oil bearings may be used on the wall
or ceiling by taking off end caps and revolving 90 or 180 degrees until
the oil wells come directly below the bearings.
STARTING.--Before starting the motor see that the armature revolves
freely, that the bearings are full of oil, and the oil rings are in place
and free to turn.
Examine connections carefully to see that they are according to above
diagram, after which proceed as follows:
1. Close the main knife switch. This action should not allow any current
to pass through the motor (see Note 2);
2. Move the lever of the starting rheostat quickly and squarely onto the
first segment, and hold it there for about a second;
3. Move the lever to the second segment and hold it there for about a
second;
4. Move the lever to the third segment and hold it there for about a
second, and so on from one segment to the next until the lever has
been moved over all the segments to the short circuit position,
where it should be held firmly by the retaining magnet.
If the motor do not start when the lever of the starting rheostat is on
the third segment, open the main knife switch and look for the trouble.
This may consist of any of the following:
a. Wrong connections;
b. Too great a load on the motor;
c. The motor brushes not in proper position;
d. An open circuit of some kind;
e. A short circuit of some kind.
NOTE 1.--It is always advisable, in case of trouble, to make sure that
the fields of the motor are magnetized. This test is easily made by first
closing the main knife switch, then moving the lever of the starting
rheostat to the first segment, and finally having an assistant place a
screw driver or other piece of iron against the pole pieces of the motor.
If the fields be magnetized, a heavy pull on the iron should result.
NOTE 2.--Any possibility of arcing on the first contact of the starting
rheostat when starting can be obviated by _first_ moving the lever onto
the initial contact, holding it there, and then closing the main line
switch, after which proceed as per paragraphs 3 and 4.
TO STOP THE MOTOR.--Open the main knife switch and let the starting
rheostat take care of itself. The lever will not fly back immediately,
but will hold until the motor has slowed down considerably.
NOTE.--The above directions apply only to starters of the sliding contact
type.
TEMPERATURES.--If located as instructed above, these motors will carry
full load as indicated on the name plate on the motor with a temperature
rise of not over 40 degrees Centigrade, or 75 degrees Fahrenheit above
the surrounding air. This will feel hot to the hand but is far below the
danger point. If the motor feel too hot, get a thermometer and measure
the temperature. To do this, place the bulb of the thermometer for 10
minutes against the frame, cover with a cloth or piece of waste, and note
temperature as compared with that of room. If the motor run in a small,
enclosed space with no ventilation, the temperatures will be somewhat
higher than those given above.
OILING.--Fill the oil wells to the overflow before starting and keep them
full. Use good "dynamo oil." Be sure that the oil rings turn freely while
the motor is running. If in a dirty place, draw off the old fluid and fill
with new every two or three months.
CARE OF MOTOR.--The motor must be kept clean. If the commutator become
rough, smooth it up with No. 00 sandpaper moistened with oil. When fitting
new brushes or changing them, always sandpaper them down until they fit
the commutator perfectly, by passing to and fro beneath the brush a strip
of sandpaper, having the rough side toward the brush.
Brushes must _always_ be renewed before the metal of the holder comes in
contact with the commutator.
Don't use anything on commutator except good mineral machine oil, or
kerosene, and this only in very small quantities applied with a cloth
having no lint or threads.]
[Illustration: Fig. 766.--Sectional view showing principal parts of
Reliance adjustable speed motor: 1, lever fulcrum pin; 2, lever; 3,
sliding thrust bearing box; 4, ball bearing; 5, armature shaft end nut;
6, cap; 7, commutator end yoke; 8, lever rod; 9, compression spring; 10,
steel frame; 11, speed adjustment nut; 12, thrust collars and pins; 13,
hand wheel rod; 14, hand wheel; 15, sleeve nut; 16, oil well cover; 17,
bearing bushing; 18, sleeve; 19, oil ring; 20, pinion end yoke; 21, rocker
arm; 22, brush holder stud; 23, brush; 24, commutator; 25, armature; 26,
armature laminations; 27, armature coils; 28, armature end plate; 29,
armature shaft; 30, leads; 31, axial position of commutating pole; 32,
axial position of main field pole; 33, slide rail screws; 34, end yoke
cap screws; 35, slide rails; 36, commutating coil; 37, commutating pole;
38, main field pole; 39, main field coil.]
[Illustration: Fig. 767.--Cutler-Hammer reversible starter with no
voltage release, adapted to start and operate motor at full speed in
either direction, such for instance as motors driving auxiliary motions
on lathes, planers and other machine tools which may rotate in either
direction but always at constant speed. They are not designed to reduce
the speed of the motor, but merely to start it and bring it smoothly up to
full speed in either direction. Two no voltage release latching devices
are provided so that the lever will be held in the full speed position
in either direction so long as the voltage of the line remains constant.
On failure of voltage a strong centering spring attached to the hub-post
of the lever throws the latter to the central, or off position. The shunt
field circuit is not opened by starters of this type.]
The weakening of the shunt field of a motor by the insertion of resistance
in the shunt field circuit causes the armature to revolve more rapidly.
One advantage of this method of control is that the motor will inherently
regulate to approximately constant speed under widely varying load
conditions. Another advantage is found in the fact that all of the
current taken from the line is utilized for power, the changes in speed
being obtained not by dissipating a portion of the effective energy
in the resistance (as in the case of the armature resistance method of
control) but by weakening the reverse voltage by inserting resistance
in the shunt field circuit. Speed increase by shunt field weakening is
limited, however, to about 10 to 15 per cent. above the normal speed in
motors of standard construction. Greater ranges of speed can be obtained
from motors especially designed for shunt field control but should not be
attempted with motors of standard design without first ascertaining from
the manufacturer the maximum safe speed.
Combined Armature and Shunt Field Control.--Regulation by combined
armature and shunt field resistance is by far the easiest way of obtaining
a wide range of speeds. Rheostats embodying these methods are known as
_compound speed regulators_, one form being shown in fig. 762. Standard
regulators can be obtained giving a wide range of speed variation, and
special regulators may be constructed giving practically any desired
range.
Selection of Starters and Regulators.--Unsatisfactory operation of these
devices is, in nearly all cases, due to lack of precaution in selecting
the proper piece of apparatus for the work to be done. One of the
commonest errors is to select a rheostat of insufficient capacity. If the
current required to operate the motor at full speed with no resistance in
circuit be greater than the rated capacity of the rheostat, overheating
of the resistance will result. An increase in temperature even to a
point where the hand cannot be held on the enclosing case need cause no
apprehension, but should the resistance become red hot it indicates that
the apparatus is being worked far beyond its capacity, and the load on the
motor should be reduced or a regulator of greater capacity substituted.
If the current required to operate the motor at full speed with no
resistance in circuit be less than the rated capacity of the rheostat no
overheating will occur, but it will not be possible to secure the full
50 per cent. speed reduction the rheostat is designed to give with all
resistance in circuit.
[Illustration: Fig. 768.--Various sizes of Watson commutator. The segments
are punched from hard drawn copper strip and are insulated from each
other and the core by amber mica, of hardness corresponding to that of
the copper in order that the wear of mica and copper may be uniform. The
segments are assembled in a ring under great pressure and are repeatedly
heated and tightened, being finally secured and rigidly locked together.]
In ordering a starter or regulator, the manufacturer should be furnished
with the following information:
1. Horse power of motor with which speed regulator will be used;
2. Voltage of motor;
3. Winding of motor, whether series, shunt, or compound wound;
4. Nature of the machine which motor is to operate;
5. Normal rated speed of motor to be used;
6. Maximum speed at which it is desired to operate the motor;
7. Minimum speed at which it is desired to operate the motor;
8. Whether controller will ever be required to reverse direction of
motor or to operate it in one direction only;
9. If reversible controller be desired, whether or not full range of
speed control is required in both directions;
10. Whether the regulator shall be equipped with any of the following
devices: no voltage release, overload release, knife switch, fuses;
11. Whether button contacts or renewable contact segments are preferred;
12. Giving, also, if possible, the resistance of the shunt field
cold, and the shunt field current at the maximum speed required.
If this cannot be ascertained, give horse power, voltage, normal
speed, maximum speed required, serial number of motor and name of
manufacturer.
[Illustration: Fig. 769.--Organ blower speed regulator; diagram showing
operation and method of installing. A cord running from the top of the
organ bellows passes over two pulleys and is then made fast to the chain
furnished with the regulator. This chain passes around a sheave which
turns on a post projecting from the center of the slate panel. Attached to
the lower end of the chain is a weight, also furnished with the regulator.
As the air is exhausted from the bellows the latter slowly collapses,
drawing the rope down with it, and in so doing turns the sheave from left
to right, thus cutting resistance out of circuit and increasing the speed
of the motor which pumps air into the bellows. Responding to the inrush of
air, the bellows expands, relaxing the tension on the rope which is now
pulled in the opposite direction by the weight, thus turning the sheave
from right to left, cutting resistance into circuit once more and slowing
down the motor. The speed of the motor is thus automatically regulated
by the bellows, with the result that a practically uniform pressure is
maintained at all times. In connection with an organ blower regulator it
is necessary to install a separate starting rheostat. This is required
for the reason that all organ bellows leak. During the intermissions in
the musical part of the service, or at other times when the blower is not
operating, the air gradually escapes and the bellows settles down, moving
the rheostat arm to the right and cutting out resistance. With the motor
at rest and the bellows empty all the blower regulator resistance would
be short circuited and it is therefore necessary to avoid throwing the
motor directly across the line when starting again. A starting rheostat
with no voltage release is suitable for this purpose, and should be
installed within easy reach of the organist, so that a moment or two
before beginning to play he can move the lever of the starting box and get
the motor into operation. Where remote control is desirable a self starter
can be substituted for the manually operated starting box, in which case
the entire installation can be controlled by a push button, or single
throw knife switch.]
[Illustration: Fig. 770.--General Electric type K7 controller with cover
open showing construction. The mechanism consists of a long spindle,
carrying a number of heavy brass or gun metal segments, making contact for
a longer or shorter time with a corresponding number of spring contacts.
The spindle is provided at its upper end with a handle, and the various
contacts are made by turning it through an arc of about 150°. For this
method a moderate amount of resistance is employed. The first contact
joins both motors and the full amount of resistance in series across
the line, and as the motors are standing still, maximum current flows so
that they exert their full torque. The moment they start to revolve, the
current tends to fall, due to the generation of a reverse voltage; to
prevent this and maintain a heavy current for some time, thus obtaining
rapid acceleration, the resistance is arranged so that it can be gradually
reduced, until at about the fourth notch the two motors are in series
without resistance across the line. To increase still further the speed in
the above type of controller, the series fields may be shunted, and then
the next steps place the motors in parallel with the resistance.]
Speed Regulation of Traction Motors.--The speed regulator for motors of
this class is called a _controller_, and being located in an exposed place
is enclosed in a metal casing. Controllers are designed to be used for
starting, stopping, reversing, and regulating the speed of motors where
one or more of these operations have to be frequently repeated.
The controller used with a single motor equipment is practically
the same as any other single motor starting box, excepting that
the resistance has sufficient carrying capacity to be left in the
circuit some time. When the motor is to operate at full speed all the
resistance is cut out. To reverse, a reversing notch is placed in the
armature or field circuit, but not in both.
Ques. What provision is made to overcome the arc when the circuit is
opened?
Ans. A magnetic field is used with such polarity that it blows out the arc.
[Illustration: Fig. 771.--Controller of the Rauch and Lang electric
vehicles. It is of the flat radial type. Two movable copper leaf contacts
of ample size make all commutations necessary to obtain the various
speeds. Five speeds forward and reverse are provided.]
Magnetic blow out coils are used on all controllers designed for 500
volt circuits, and on types designed for lower voltages requiring more
than 60 amperes normal capacity.
The coils are wound with either copper wire or flat strips of
sufficient capacity to carry full load current continuously without
undue heating, and after being wound they are treated with an
insulating compound making them moisture proof.
Ques. What provision is made to prevent reversal before bringing the
controller lever to the "off" position?
Ans. Controllers having separate reversing cylinders are fitted with
mechanical interlocks making it necessary to place lever in off position
before reversing.
[Illustration: Figs. 772 to 782.--Diagram of controller connections,
illustrating the series parallel method of two motor control.]
Two Motor Regulation.--With a two motor equipment, the controller becomes
more complicated because it must be arranged to switch the motors in
series or in parallel, so as to secure economy at half and full speed.
The various connections of series-parallel regulation are shown in figs.
772 to 782.
From these diagrams it is seen that the motors are first operated in
series until all the resistance is cut out by the controller (figs.
772 to 777).
The next point on the controller puts the two motors in parallel
with some resistance in the circuit (fig. 778), which resistance is
gradually short circuited on the remaining controller points, until
at full speed all the resistance is cut out, the two motors remaining
in parallel (figs. 778 to 782).
Stopping a Motor.--If it be desired to stop a motor, the main switch
is opened. As the armature of the motor continues to operate, due to
its inertia, it generates an electromotive force which sends a current
through the shunt connected field circuit and helps to maintain the field
excitation. When the speed of the motor has decreased sufficiently so as
not to endanger the motor should the main switch be thrown, the current
in the series magnet becomes weakened, and the spring throws back the
starting box arm.
It should be noted that in stopping a motor having a starting box provided
with a no voltage release simply open the main switch and do not touch the
lever because otherwise, the self induced voltage of the field circuit
may puncture the field winding or the insulation of the adjoining wires
in the starting box.
HAWKINS PRACTICAL LIBRARY OF
ELECTRICITY
IN HANDY POCKET FORM PRICE $1 EACH
_They are not only the best, but the cheapest work published on
Electricity. Each number being complete in itself. Separate numbers
sent postpaid to any address on receipt of price. They are guaranteed
in every way or your money will be returned. Complete catalog of
series will be mailed free on request._
ELECTRICAL GUIDE, NO. 1
Containing the principles of Elementary Electricity, Magnetism,
Induction, Experiments, Dynamos, Electric Machinery.
ELECTRICAL GUIDE, NO. 2
The construction of Dynamos, Motors, Armatures, Armature Windings,
Installing of Dynamos.
ELECTRICAL GUIDE, NO. 3
Electrical Instruments, Testing, Practical Management of Dynamos
and Motors.
ELECTRICAL GUIDE, NO. 4
Distribution Systems, Wiring, Wiring Diagrams, Sign Flashers,
Storage Batteries.
ELECTRICAL GUIDE, NO. 5
Principles of Alternating Currents and Alternators.
ELECTRICAL GUIDE, NO. 6
Alternating Current Motors, Transformers, Converters, Rectifiers.
ELECTRICAL GUIDE, NO. 7
Alternating Current Systems, Circuit Breakers, Measuring
Instruments.
ELECTRICAL GUIDE, NO. 8
Alternating Current Switch Boards, Wiring, Power Stations,
Installation and Operation.
ELECTRICAL GUIDE, NO. 9
Telephone, Telegraph, Wireless, Bells, Lighting, Railways.
ELECTRICAL GUIDE, NO. 10
Modern Practical Applications of Electricity and Ready Reference
Index of the 10 Numbers.
Theo. Audel & Co. Publishers 72 FIFTH AVENUE, NEW YORK
End of the Project Gutenberg EBook of Hawkins Electrical Guide v. 3 (of 10), by
Nehemiah Hawkins
*** END OF THE PROJECT GUTENBERG EBOOK 49769 ***
|